Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization

We evaluate geometric shifts of daily setup for evaluating the appropriateness of treatment and determining proper margins for the planning target volume (PTV) in prostate cancer patients. We analyzed 1200 sets of pretreatment megavoltage-CT scans that were acquired from 40 patients with intermediat...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Songmi, Lee, Jong Hoon, Chung, Mi Joo, Lee, Sea Won, Lee, Jeong Won, Kang, Dae Gyu, Kim, Sung Hwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4718244/
https://www.ncbi.nlm.nih.gov/pubmed/26765418
http://dx.doi.org/10.1097/MD.0000000000002387
_version_ 1782410761778233344
author Jeong, Songmi
Lee, Jong Hoon
Chung, Mi Joo
Lee, Sea Won
Lee, Jeong Won
Kang, Dae Gyu
Kim, Sung Hwan
author_facet Jeong, Songmi
Lee, Jong Hoon
Chung, Mi Joo
Lee, Sea Won
Lee, Jeong Won
Kang, Dae Gyu
Kim, Sung Hwan
author_sort Jeong, Songmi
collection PubMed
description We evaluate geometric shifts of daily setup for evaluating the appropriateness of treatment and determining proper margins for the planning target volume (PTV) in prostate cancer patients. We analyzed 1200 sets of pretreatment megavoltage-CT scans that were acquired from 40 patients with intermediate to high-risk prostate cancer. They received whole pelvic intensity-modulated radiotherapy (IMRT). They underwent daily endorectal ballooning and enema to limit intrapelvic organ movement. The mean and standard deviation (SD) of daily translational shifts in right-to-left (X), anterior-to-posterior (Y), and superior-to-inferior (Z) were evaluated for systemic and random error. The mean ± SD of systemic error (Σ) in X, Y, Z, and roll was 2.21 ± 3.42 mm, −0.67 ± 2.27 mm, 1.05 ± 2.87 mm, and −0.43 ± 0.89°, respectively. The mean ± SD of random error (δ) was 1.95 ± 1.60 mm in X, 1.02 ± 0.50 mm in Y, 1.01 ± 0.48 mm in Z, and 0.37 ± 0.15° in roll. The calculated proper PTV margins that cover >95% of the target on average were 8.20 (X), 5.25 (Y), and 6.45 (Z) mm. Mean systemic geometrical shifts of IMRT were not statistically different in all transitional and three-dimensional shifts from early to late weeks. There was no grade 3 or higher gastrointestinal or genitourianry toxicity. The whole pelvic IMRT technique is a feasible and effective modality that limits intrapelvic organ motion and reduces setup uncertainties. Proper margins for the PTV can be determined by using geometric shifts data.
format Online
Article
Text
id pubmed-4718244
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-47182442016-02-04 Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization Jeong, Songmi Lee, Jong Hoon Chung, Mi Joo Lee, Sea Won Lee, Jeong Won Kang, Dae Gyu Kim, Sung Hwan Medicine (Baltimore) 5700 We evaluate geometric shifts of daily setup for evaluating the appropriateness of treatment and determining proper margins for the planning target volume (PTV) in prostate cancer patients. We analyzed 1200 sets of pretreatment megavoltage-CT scans that were acquired from 40 patients with intermediate to high-risk prostate cancer. They received whole pelvic intensity-modulated radiotherapy (IMRT). They underwent daily endorectal ballooning and enema to limit intrapelvic organ movement. The mean and standard deviation (SD) of daily translational shifts in right-to-left (X), anterior-to-posterior (Y), and superior-to-inferior (Z) were evaluated for systemic and random error. The mean ± SD of systemic error (Σ) in X, Y, Z, and roll was 2.21 ± 3.42 mm, −0.67 ± 2.27 mm, 1.05 ± 2.87 mm, and −0.43 ± 0.89°, respectively. The mean ± SD of random error (δ) was 1.95 ± 1.60 mm in X, 1.02 ± 0.50 mm in Y, 1.01 ± 0.48 mm in Z, and 0.37 ± 0.15° in roll. The calculated proper PTV margins that cover >95% of the target on average were 8.20 (X), 5.25 (Y), and 6.45 (Z) mm. Mean systemic geometrical shifts of IMRT were not statistically different in all transitional and three-dimensional shifts from early to late weeks. There was no grade 3 or higher gastrointestinal or genitourianry toxicity. The whole pelvic IMRT technique is a feasible and effective modality that limits intrapelvic organ motion and reduces setup uncertainties. Proper margins for the PTV can be determined by using geometric shifts data. Wolters Kluwer Health 2016-01-15 /pmc/articles/PMC4718244/ /pubmed/26765418 http://dx.doi.org/10.1097/MD.0000000000002387 Text en Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 5700
Jeong, Songmi
Lee, Jong Hoon
Chung, Mi Joo
Lee, Sea Won
Lee, Jeong Won
Kang, Dae Gyu
Kim, Sung Hwan
Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization
title Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization
title_full Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization
title_fullStr Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization
title_full_unstemmed Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization
title_short Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization
title_sort analysis of geometric shifts and proper setup-margin in prostate cancer patients treated with pelvic intensity-modulated radiotherapy using endorectal ballooning and daily enema for prostate immobilization
topic 5700
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4718244/
https://www.ncbi.nlm.nih.gov/pubmed/26765418
http://dx.doi.org/10.1097/MD.0000000000002387
work_keys_str_mv AT jeongsongmi analysisofgeometricshiftsandpropersetupmargininprostatecancerpatientstreatedwithpelvicintensitymodulatedradiotherapyusingendorectalballooninganddailyenemaforprostateimmobilization
AT leejonghoon analysisofgeometricshiftsandpropersetupmargininprostatecancerpatientstreatedwithpelvicintensitymodulatedradiotherapyusingendorectalballooninganddailyenemaforprostateimmobilization
AT chungmijoo analysisofgeometricshiftsandpropersetupmargininprostatecancerpatientstreatedwithpelvicintensitymodulatedradiotherapyusingendorectalballooninganddailyenemaforprostateimmobilization
AT leeseawon analysisofgeometricshiftsandpropersetupmargininprostatecancerpatientstreatedwithpelvicintensitymodulatedradiotherapyusingendorectalballooninganddailyenemaforprostateimmobilization
AT leejeongwon analysisofgeometricshiftsandpropersetupmargininprostatecancerpatientstreatedwithpelvicintensitymodulatedradiotherapyusingendorectalballooninganddailyenemaforprostateimmobilization
AT kangdaegyu analysisofgeometricshiftsandpropersetupmargininprostatecancerpatientstreatedwithpelvicintensitymodulatedradiotherapyusingendorectalballooninganddailyenemaforprostateimmobilization
AT kimsunghwan analysisofgeometricshiftsandpropersetupmargininprostatecancerpatientstreatedwithpelvicintensitymodulatedradiotherapyusingendorectalballooninganddailyenemaforprostateimmobilization