Cargando…

Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications

BACKGROUND: Sensitive and specific detection of malarial parasites is crucial in controlling the significant malaria burden in the developing world. Also important is being able to identify life threatening Plasmodium falciparum malaria quickly and accurately to reduce malaria related mortality. Exi...

Descripción completa

Detalles Bibliográficos
Autores principales: Nair, Chandrasekhar Bhaskaran, Manjula, Jagannath, Subramani, Pradeep Annamalai, Nagendrappa, Prakash B., Manoj, Mulakkapurath Narayanan, Malpani, Sukriti, Pullela, Phani Kumar, Subbarao, Pillarisetti Venkata, Ramamoorthy, Siva, Ghosh, Susanta K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4718663/
https://www.ncbi.nlm.nih.gov/pubmed/26784111
http://dx.doi.org/10.1371/journal.pone.0146961
_version_ 1782410835551846400
author Nair, Chandrasekhar Bhaskaran
Manjula, Jagannath
Subramani, Pradeep Annamalai
Nagendrappa, Prakash B.
Manoj, Mulakkapurath Narayanan
Malpani, Sukriti
Pullela, Phani Kumar
Subbarao, Pillarisetti Venkata
Ramamoorthy, Siva
Ghosh, Susanta K.
author_facet Nair, Chandrasekhar Bhaskaran
Manjula, Jagannath
Subramani, Pradeep Annamalai
Nagendrappa, Prakash B.
Manoj, Mulakkapurath Narayanan
Malpani, Sukriti
Pullela, Phani Kumar
Subbarao, Pillarisetti Venkata
Ramamoorthy, Siva
Ghosh, Susanta K.
author_sort Nair, Chandrasekhar Bhaskaran
collection PubMed
description BACKGROUND: Sensitive and specific detection of malarial parasites is crucial in controlling the significant malaria burden in the developing world. Also important is being able to identify life threatening Plasmodium falciparum malaria quickly and accurately to reduce malaria related mortality. Existing methods such as microscopy and rapid diagnostic tests (RDTs) have major shortcomings. Here, we describe a new real-time PCR-based diagnostic test device at point-of-care service for resource-limited settings. METHODS: Truenat(®) Malaria, a chip-based microPCR test, was developed by bigtec Labs, Bangalore, India, for differential identification of Plasmodium falciparum and Plasmodium vivax parasites. The Truenat Malaria tests runs on bigtec’s Truelab Uno(®) microPCR device, a handheld, battery operated, and easy-to-use real-time microPCR device. The performance of Truenat(®) Malaria was evaluated versus the WHO nested PCR protocol. The Truenat(®) Malaria was further evaluated in a triple-blinded study design using a sample panel of 281 specimens created from the clinical samples characterized by expert microscopy and a rapid diagnostic test kit by the National Institute of Malaria Research (NIMR). A comparative evaluation was done on the Truelab Uno(®) and a commercial real-time PCR system. RESULTS: The limit of detection of the Truenat Malaria assay was found to be <5 parasites/μl for both P. falciparum and P. vivax. The Truenat(®) Malaria test was found to have sensitivity and specificity of 100% each, compared to the WHO nested PCR protocol based on the evaluation of 100 samples. The sensitivity using expert microscopy as the reference standard was determined to be around 99.3% (95% CI: 95.5–99.9) at the species level. Mixed infections were identified more accurately by Truenat Malaria (32 samples identified as mixed) versus expert microscopy and RDTs which detected 4 and 5 mixed samples, respectively. CONCLUSION: The Truenat(®) Malaria microPCR test is a valuable diagnostic tool and implementation should be considered not only for malaria diagnosis but also for active surveillance and epidemiological intervention.
format Online
Article
Text
id pubmed-4718663
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47186632016-01-30 Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications Nair, Chandrasekhar Bhaskaran Manjula, Jagannath Subramani, Pradeep Annamalai Nagendrappa, Prakash B. Manoj, Mulakkapurath Narayanan Malpani, Sukriti Pullela, Phani Kumar Subbarao, Pillarisetti Venkata Ramamoorthy, Siva Ghosh, Susanta K. PLoS One Research Article BACKGROUND: Sensitive and specific detection of malarial parasites is crucial in controlling the significant malaria burden in the developing world. Also important is being able to identify life threatening Plasmodium falciparum malaria quickly and accurately to reduce malaria related mortality. Existing methods such as microscopy and rapid diagnostic tests (RDTs) have major shortcomings. Here, we describe a new real-time PCR-based diagnostic test device at point-of-care service for resource-limited settings. METHODS: Truenat(®) Malaria, a chip-based microPCR test, was developed by bigtec Labs, Bangalore, India, for differential identification of Plasmodium falciparum and Plasmodium vivax parasites. The Truenat Malaria tests runs on bigtec’s Truelab Uno(®) microPCR device, a handheld, battery operated, and easy-to-use real-time microPCR device. The performance of Truenat(®) Malaria was evaluated versus the WHO nested PCR protocol. The Truenat(®) Malaria was further evaluated in a triple-blinded study design using a sample panel of 281 specimens created from the clinical samples characterized by expert microscopy and a rapid diagnostic test kit by the National Institute of Malaria Research (NIMR). A comparative evaluation was done on the Truelab Uno(®) and a commercial real-time PCR system. RESULTS: The limit of detection of the Truenat Malaria assay was found to be <5 parasites/μl for both P. falciparum and P. vivax. The Truenat(®) Malaria test was found to have sensitivity and specificity of 100% each, compared to the WHO nested PCR protocol based on the evaluation of 100 samples. The sensitivity using expert microscopy as the reference standard was determined to be around 99.3% (95% CI: 95.5–99.9) at the species level. Mixed infections were identified more accurately by Truenat Malaria (32 samples identified as mixed) versus expert microscopy and RDTs which detected 4 and 5 mixed samples, respectively. CONCLUSION: The Truenat(®) Malaria microPCR test is a valuable diagnostic tool and implementation should be considered not only for malaria diagnosis but also for active surveillance and epidemiological intervention. Public Library of Science 2016-01-19 /pmc/articles/PMC4718663/ /pubmed/26784111 http://dx.doi.org/10.1371/journal.pone.0146961 Text en © 2016 Nair et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Nair, Chandrasekhar Bhaskaran
Manjula, Jagannath
Subramani, Pradeep Annamalai
Nagendrappa, Prakash B.
Manoj, Mulakkapurath Narayanan
Malpani, Sukriti
Pullela, Phani Kumar
Subbarao, Pillarisetti Venkata
Ramamoorthy, Siva
Ghosh, Susanta K.
Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications
title Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications
title_full Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications
title_fullStr Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications
title_full_unstemmed Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications
title_short Differential Diagnosis of Malaria on Truelab Uno(®), a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications
title_sort differential diagnosis of malaria on truelab uno(®), a portable, real-time, micropcr device for point-of-care applications
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4718663/
https://www.ncbi.nlm.nih.gov/pubmed/26784111
http://dx.doi.org/10.1371/journal.pone.0146961
work_keys_str_mv AT nairchandrasekharbhaskaran differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT manjulajagannath differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT subramanipradeepannamalai differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT nagendrappaprakashb differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT manojmulakkapurathnarayanan differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT malpanisukriti differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT pullelaphanikumar differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT subbaraopillarisettivenkata differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT ramamoorthysiva differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications
AT ghoshsusantak differentialdiagnosisofmalariaontruelabunoaportablerealtimemicropcrdeviceforpointofcareapplications