An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation
INTRODUCTION: Proximal humeral fractures account for 4% to 5% of all fractures. Complex proximal humeral fractures with displaced three- and four-part fragments, humeral head splits and fracture-dislocations are more difficult to treat. In older patients, because of poor bone quality, hemiarthroplas...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719380/ https://www.ncbi.nlm.nih.gov/pubmed/27298964 http://dx.doi.org/10.13107/jocr.2250-0685.172 |
_version_ | 1782410927615770624 |
---|---|
author | Gunay, Cuneyd Oken, Fuad Yildirim, Ahmet Ozgur Ucaner, Ahmet |
author_facet | Gunay, Cuneyd Oken, Fuad Yildirim, Ahmet Ozgur Ucaner, Ahmet |
author_sort | Gunay, Cuneyd |
collection | PubMed |
description | INTRODUCTION: Proximal humeral fractures account for 4% to 5% of all fractures. Complex proximal humeral fractures with displaced three- and four-part fragments, humeral head splits and fracture-dislocations are more difficult to treat. In older patients, because of poor bone quality, hemiarthroplasty is often the indicated treatment. CASE REPORT: One such case of a 73-year-old woman is presented here. The patient presented with a four-part fracture of the proximal humerus, with displacement of the humeral head. Hemiarthroplasty was done in the right shoulder. At postoperative 20 days, during physical therapy, the humeral head component of the prosthesis disengaged and a second operation was necessary. A deltopectoral approach was repeated using the previous incision. The humeral stem was seen to be well-fixed into the bone so the humeral head was changed for a new one of the same size. At two years, the dominant right side had active, painless ROM. CONCLUSION: The management and two-year follow-up of this case is reported here, which was the first to occur at our institution. |
format | Online Article Text |
id | pubmed-4719380 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-47193802016-06-13 An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation Gunay, Cuneyd Oken, Fuad Yildirim, Ahmet Ozgur Ucaner, Ahmet J Orthop Case Rep Case Report INTRODUCTION: Proximal humeral fractures account for 4% to 5% of all fractures. Complex proximal humeral fractures with displaced three- and four-part fragments, humeral head splits and fracture-dislocations are more difficult to treat. In older patients, because of poor bone quality, hemiarthroplasty is often the indicated treatment. CASE REPORT: One such case of a 73-year-old woman is presented here. The patient presented with a four-part fracture of the proximal humerus, with displacement of the humeral head. Hemiarthroplasty was done in the right shoulder. At postoperative 20 days, during physical therapy, the humeral head component of the prosthesis disengaged and a second operation was necessary. A deltopectoral approach was repeated using the previous incision. The humeral stem was seen to be well-fixed into the bone so the humeral head was changed for a new one of the same size. At two years, the dominant right side had active, painless ROM. CONCLUSION: The management and two-year follow-up of this case is reported here, which was the first to occur at our institution. Indian Orthopaedic Research Group 2014 /pmc/articles/PMC4719380/ /pubmed/27298964 http://dx.doi.org/10.13107/jocr.2250-0685.172 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc-sa/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc-sa/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Gunay, Cuneyd Oken, Fuad Yildirim, Ahmet Ozgur Ucaner, Ahmet An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation |
title | An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation |
title_full | An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation |
title_fullStr | An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation |
title_full_unstemmed | An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation |
title_short | An Unusual Disengagement of the Humeral Head Component after Hemiarthroplasty: A Case Report Presentation |
title_sort | unusual disengagement of the humeral head component after hemiarthroplasty: a case report presentation |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719380/ https://www.ncbi.nlm.nih.gov/pubmed/27298964 http://dx.doi.org/10.13107/jocr.2250-0685.172 |
work_keys_str_mv | AT gunaycuneyd anunusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation AT okenfuad anunusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation AT yildirimahmetozgur anunusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation AT ucanerahmet anunusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation AT gunaycuneyd unusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation AT okenfuad unusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation AT yildirimahmetozgur unusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation AT ucanerahmet unusualdisengagementofthehumeralheadcomponentafterhemiarthroplastyacasereportpresentation |