An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur

INTRODUCTION: Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doi...

Descripción completa

Detalles Bibliográficos
Autores principales: Huda, Najmul, Julfiqar, Pant, Ajay, Aslam, M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719399/
https://www.ncbi.nlm.nih.gov/pubmed/27299067
http://dx.doi.org/10.13107/jocr.2250-0685.305
_version_ 1782410931950583808
author Huda, Najmul
Julfiqar,
Pant, Ajay
Aslam, M
author_facet Huda, Najmul
Julfiqar,
Pant, Ajay
Aslam, M
author_sort Huda, Najmul
collection PubMed
description INTRODUCTION: Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doing a press fit modular bipolar hemiarthroplasty, in a young adult with secondary nonunion of the femoral neck fracture. The cause of this proximal femur perforation was residual fibular strut graft that, redirected the femoral stem into undesirable direction. This complication of residual fibular strut graft has not been disscussed much in the orthopedic literature previously. CASE REPORT: A press fit modular bipolar hiparthroplasty was performed in a young adult male with nonunion fracture neck of the femur secondary to initial fixation using 6.5mm cannulated hip screws and nonvascularized free fibular strut grafting. Failure to completely remove the fibular strut from the proximal femur lead to difficult negotiation of the femoral stem into the femoral canal and ultimately a perforation in the proximal femur at the level of the lesser trochanter. A revision procedure was done to completely remove the residual fibular graft, and then a fresh press fit modular bipolar hemiarthroplasty was done. CONCLUSION: Complete removal of fibular strut graft should be done, while performing hip arthroplasty in patients with failed fibular grafting for fracture neck of the femur.
format Online
Article
Text
id pubmed-4719399
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-47193992016-06-13 An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur Huda, Najmul Julfiqar, Pant, Ajay Aslam, M J Orthop Case Rep Case Report INTRODUCTION: Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doing a press fit modular bipolar hemiarthroplasty, in a young adult with secondary nonunion of the femoral neck fracture. The cause of this proximal femur perforation was residual fibular strut graft that, redirected the femoral stem into undesirable direction. This complication of residual fibular strut graft has not been disscussed much in the orthopedic literature previously. CASE REPORT: A press fit modular bipolar hiparthroplasty was performed in a young adult male with nonunion fracture neck of the femur secondary to initial fixation using 6.5mm cannulated hip screws and nonvascularized free fibular strut grafting. Failure to completely remove the fibular strut from the proximal femur lead to difficult negotiation of the femoral stem into the femoral canal and ultimately a perforation in the proximal femur at the level of the lesser trochanter. A revision procedure was done to completely remove the residual fibular graft, and then a fresh press fit modular bipolar hemiarthroplasty was done. CONCLUSION: Complete removal of fibular strut graft should be done, while performing hip arthroplasty in patients with failed fibular grafting for fracture neck of the femur. Indian Orthopaedic Research Group 2015 /pmc/articles/PMC4719399/ /pubmed/27299067 http://dx.doi.org/10.13107/jocr.2250-0685.305 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc-sa/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc-sa/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Huda, Najmul
Julfiqar,
Pant, Ajay
Aslam, M
An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
title An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
title_full An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
title_fullStr An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
title_full_unstemmed An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
title_short An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
title_sort unexpected complication of residual fibular strut graft while performing a press fit hemiarthroplasty for a secondary nonunion fracture neck of the femur
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719399/
https://www.ncbi.nlm.nih.gov/pubmed/27299067
http://dx.doi.org/10.13107/jocr.2250-0685.305
work_keys_str_mv AT hudanajmul anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur
AT julfiqar anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur
AT pantajay anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur
AT aslamm anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur
AT hudanajmul unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur
AT julfiqar unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur
AT pantajay unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur
AT aslamm unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur