Cargando…
An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur
INTRODUCTION: Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Orthopaedic Research Group
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719399/ https://www.ncbi.nlm.nih.gov/pubmed/27299067 http://dx.doi.org/10.13107/jocr.2250-0685.305 |
_version_ | 1782410931950583808 |
---|---|
author | Huda, Najmul Julfiqar, Pant, Ajay Aslam, M |
author_facet | Huda, Najmul Julfiqar, Pant, Ajay Aslam, M |
author_sort | Huda, Najmul |
collection | PubMed |
description | INTRODUCTION: Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doing a press fit modular bipolar hemiarthroplasty, in a young adult with secondary nonunion of the femoral neck fracture. The cause of this proximal femur perforation was residual fibular strut graft that, redirected the femoral stem into undesirable direction. This complication of residual fibular strut graft has not been disscussed much in the orthopedic literature previously. CASE REPORT: A press fit modular bipolar hiparthroplasty was performed in a young adult male with nonunion fracture neck of the femur secondary to initial fixation using 6.5mm cannulated hip screws and nonvascularized free fibular strut grafting. Failure to completely remove the fibular strut from the proximal femur lead to difficult negotiation of the femoral stem into the femoral canal and ultimately a perforation in the proximal femur at the level of the lesser trochanter. A revision procedure was done to completely remove the residual fibular graft, and then a fresh press fit modular bipolar hemiarthroplasty was done. CONCLUSION: Complete removal of fibular strut graft should be done, while performing hip arthroplasty in patients with failed fibular grafting for fracture neck of the femur. |
format | Online Article Text |
id | pubmed-4719399 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Indian Orthopaedic Research Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-47193992016-06-13 An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur Huda, Najmul Julfiqar, Pant, Ajay Aslam, M J Orthop Case Rep Case Report INTRODUCTION: Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doing a press fit modular bipolar hemiarthroplasty, in a young adult with secondary nonunion of the femoral neck fracture. The cause of this proximal femur perforation was residual fibular strut graft that, redirected the femoral stem into undesirable direction. This complication of residual fibular strut graft has not been disscussed much in the orthopedic literature previously. CASE REPORT: A press fit modular bipolar hiparthroplasty was performed in a young adult male with nonunion fracture neck of the femur secondary to initial fixation using 6.5mm cannulated hip screws and nonvascularized free fibular strut grafting. Failure to completely remove the fibular strut from the proximal femur lead to difficult negotiation of the femoral stem into the femoral canal and ultimately a perforation in the proximal femur at the level of the lesser trochanter. A revision procedure was done to completely remove the residual fibular graft, and then a fresh press fit modular bipolar hemiarthroplasty was done. CONCLUSION: Complete removal of fibular strut graft should be done, while performing hip arthroplasty in patients with failed fibular grafting for fracture neck of the femur. Indian Orthopaedic Research Group 2015 /pmc/articles/PMC4719399/ /pubmed/27299067 http://dx.doi.org/10.13107/jocr.2250-0685.305 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc-sa/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc-sa/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Huda, Najmul Julfiqar, Pant, Ajay Aslam, M An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur |
title | An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur |
title_full | An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur |
title_fullStr | An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur |
title_full_unstemmed | An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur |
title_short | An Unexpected Complication of Residual Fibular Strut Graft While Performing A Press fit Hemiarthroplasty for A Secondary Nonunion Fracture Neck of the Femur |
title_sort | unexpected complication of residual fibular strut graft while performing a press fit hemiarthroplasty for a secondary nonunion fracture neck of the femur |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4719399/ https://www.ncbi.nlm.nih.gov/pubmed/27299067 http://dx.doi.org/10.13107/jocr.2250-0685.305 |
work_keys_str_mv | AT hudanajmul anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur AT julfiqar anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur AT pantajay anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur AT aslamm anunexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur AT hudanajmul unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur AT julfiqar unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur AT pantajay unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur AT aslamm unexpectedcomplicationofresidualfibularstrutgraftwhileperformingapressfithemiarthroplastyforasecondarynonunionfractureneckofthefemur |