Cargando…
Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study
OBJECTIVE: To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). MATERIALS AND...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4720814/ https://www.ncbi.nlm.nih.gov/pubmed/26798218 http://dx.doi.org/10.3348/kjr.2016.17.1.69 |
_version_ | 1782411132730867712 |
---|---|
author | Pei, Yigang Li, Fang Shen, Hao Long, Xueying Liu, Hui Wang, Xiaoyi Liu, Jinkang Li, Wenzheng |
author_facet | Pei, Yigang Li, Fang Shen, Hao Long, Xueying Liu, Hui Wang, Xiaoyi Liu, Jinkang Li, Wenzheng |
author_sort | Pei, Yigang |
collection | PubMed |
description | OBJECTIVE: To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). MATERIALS AND METHODS: This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. RESULTS: The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. CONCLUSION: In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency. |
format | Online Article Text |
id | pubmed-4720814 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-47208142016-01-21 Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study Pei, Yigang Li, Fang Shen, Hao Long, Xueying Liu, Hui Wang, Xiaoyi Liu, Jinkang Li, Wenzheng Korean J Radiol Cardiovascular Imaging OBJECTIVE: To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). MATERIALS AND METHODS: This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. RESULTS: The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. CONCLUSION: In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency. The Korean Society of Radiology 2016 2016-01-06 /pmc/articles/PMC4720814/ /pubmed/26798218 http://dx.doi.org/10.3348/kjr.2016.17.1.69 Text en Copyright © 2016 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cardiovascular Imaging Pei, Yigang Li, Fang Shen, Hao Long, Xueying Liu, Hui Wang, Xiaoyi Liu, Jinkang Li, Wenzheng Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study |
title | Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study |
title_full | Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study |
title_fullStr | Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study |
title_full_unstemmed | Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study |
title_short | Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study |
title_sort | optimal blood suppression inversion time based on breathing rates and heart rates to improve renal artery visibility in spatial labeling with multiple inversion pulses: a preliminary study |
topic | Cardiovascular Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4720814/ https://www.ncbi.nlm.nih.gov/pubmed/26798218 http://dx.doi.org/10.3348/kjr.2016.17.1.69 |
work_keys_str_mv | AT peiyigang optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy AT lifang optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy AT shenhao optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy AT longxueying optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy AT liuhui optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy AT wangxiaoyi optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy AT liujinkang optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy AT liwenzheng optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy |