Cargando…

Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study

OBJECTIVE: To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). MATERIALS AND...

Descripción completa

Detalles Bibliográficos
Autores principales: Pei, Yigang, Li, Fang, Shen, Hao, Long, Xueying, Liu, Hui, Wang, Xiaoyi, Liu, Jinkang, Li, Wenzheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4720814/
https://www.ncbi.nlm.nih.gov/pubmed/26798218
http://dx.doi.org/10.3348/kjr.2016.17.1.69
_version_ 1782411132730867712
author Pei, Yigang
Li, Fang
Shen, Hao
Long, Xueying
Liu, Hui
Wang, Xiaoyi
Liu, Jinkang
Li, Wenzheng
author_facet Pei, Yigang
Li, Fang
Shen, Hao
Long, Xueying
Liu, Hui
Wang, Xiaoyi
Liu, Jinkang
Li, Wenzheng
author_sort Pei, Yigang
collection PubMed
description OBJECTIVE: To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). MATERIALS AND METHODS: This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. RESULTS: The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. CONCLUSION: In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency.
format Online
Article
Text
id pubmed-4720814
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-47208142016-01-21 Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study Pei, Yigang Li, Fang Shen, Hao Long, Xueying Liu, Hui Wang, Xiaoyi Liu, Jinkang Li, Wenzheng Korean J Radiol Cardiovascular Imaging OBJECTIVE: To determine whether an optimal blood suppression inversion time (BSP TI) can boost arterial visibility and whether the optimal BSP TI is related to breathing rate (BR) and heart rate (HR) for hypertension subjects in spatial labeling with multiple inversion pulses (SLEEK). MATERIALS AND METHODS: This prospective study included 10 volunteers and 93 consecutive hypertension patients who had undergone SLEEK at 1.5T MRI system. Firstly, suitable BSP TIs for displaying clearly renal artery were determined in 10 volunteers. Secondly, non-contrast enhanced magnetic resonance angiography with the suitable BSP TIs were performed on those hypertension patients. Then, renal artery was evaluated and an optimal BSP TI to increase arterial visibility was determined for each patient. Patients' BRs and HRs were recorded and their relationships with the optimal BSP TI were analyzed. RESULTS: The optimal BSP TI was negatively correlated with BR (r1 = -0.536, P1 < 0.001; and r2 = -0.535, P2 < 0.001) and HR (r1 = -0.432, P1 = 0.001; and r2 = -0.419, P2 = 0.001) for 2 readers (κ = 0.93). For improving renal arterial visibility, BSP TI = 800 ms could be applied as the optimal BSP TI when the 95% confidence interval were 17-19/min (BR1) and 74-82 bpm (HR1) for reader#1 and 17-19/min (BR2) and 74-83 bpm (HR2) for reader#2; BSP TI = 1100 ms while 14-15/min (BR1, 2) and 71-76 bpm (HR1, 2) for both readers; and BSP TI = 1400 ms when 13-16/min (BR1) and 63-68 bpm (HR1) for reader#1 and 14-15/min (BR2) and 64-70 bpm (HR2) for reader#2. CONCLUSION: In SLEEK, BSP TI is affected by patients' BRs and HRs. Adopting the optimal BSP TI based on BR and HR can improve the renal arterial visibility and consequently the working efficiency. The Korean Society of Radiology 2016 2016-01-06 /pmc/articles/PMC4720814/ /pubmed/26798218 http://dx.doi.org/10.3348/kjr.2016.17.1.69 Text en Copyright © 2016 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Pei, Yigang
Li, Fang
Shen, Hao
Long, Xueying
Liu, Hui
Wang, Xiaoyi
Liu, Jinkang
Li, Wenzheng
Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study
title Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study
title_full Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study
title_fullStr Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study
title_full_unstemmed Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study
title_short Optimal Blood Suppression Inversion Time Based on Breathing Rates and Heart Rates to Improve Renal Artery Visibility in Spatial Labeling with Multiple Inversion Pulses: A Preliminary Study
title_sort optimal blood suppression inversion time based on breathing rates and heart rates to improve renal artery visibility in spatial labeling with multiple inversion pulses: a preliminary study
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4720814/
https://www.ncbi.nlm.nih.gov/pubmed/26798218
http://dx.doi.org/10.3348/kjr.2016.17.1.69
work_keys_str_mv AT peiyigang optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy
AT lifang optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy
AT shenhao optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy
AT longxueying optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy
AT liuhui optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy
AT wangxiaoyi optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy
AT liujinkang optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy
AT liwenzheng optimalbloodsuppressioninversiontimebasedonbreathingratesandheartratestoimproverenalarteryvisibilityinspatiallabelingwithmultipleinversionpulsesapreliminarystudy