Cargando…

Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements

Vision based interfaces for human computer interaction have gained increasing attention over the past decade. This study presents a data fusion approach of the Nimble VR vision based system, using the Kinect camera, with the contact based 5DT Data Glove. Data fusion was achieved through a Kalman fil...

Descripción completa

Detalles Bibliográficos
Autores principales: Arkenbout, Ewout A., de Winter, Joost C. F., Breedveld, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4721788/
https://www.ncbi.nlm.nih.gov/pubmed/26694395
http://dx.doi.org/10.3390/s151229868
_version_ 1782411281367564288
author Arkenbout, Ewout A.
de Winter, Joost C. F.
Breedveld, Paul
author_facet Arkenbout, Ewout A.
de Winter, Joost C. F.
Breedveld, Paul
author_sort Arkenbout, Ewout A.
collection PubMed
description Vision based interfaces for human computer interaction have gained increasing attention over the past decade. This study presents a data fusion approach of the Nimble VR vision based system, using the Kinect camera, with the contact based 5DT Data Glove. Data fusion was achieved through a Kalman filter. The Nimble VR and filter output were compared using measurements performed on (1) a wooden hand model placed in various static postures and orientations; and (2) three differently sized human hands during active finger flexions. Precision and accuracy of joint angle estimates as a function of hand posture and orientation were determined. Moreover, in light of possible self-occlusions of the fingers in the Kinect camera images, data completeness was assessed. Results showed that the integration of the Data Glove through the Kalman filter provided for the proximal interphalangeal (PIP) joints of the fingers a substantial improvement of 79% in precision, from 2.2 deg to 0.9 deg. Moreover, a moderate improvement of 31% in accuracy (being the mean angular deviation from the true joint angle) was established, from 24 deg to 17 deg. The metacarpophalangeal (MCP) joint was relatively unaffected by the Kalman filter. Moreover, the Data Glove increased data completeness, thus providing a substantial advantage over the sole use of the Nimble VR system.
format Online
Article
Text
id pubmed-4721788
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-47217882016-01-26 Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements Arkenbout, Ewout A. de Winter, Joost C. F. Breedveld, Paul Sensors (Basel) Article Vision based interfaces for human computer interaction have gained increasing attention over the past decade. This study presents a data fusion approach of the Nimble VR vision based system, using the Kinect camera, with the contact based 5DT Data Glove. Data fusion was achieved through a Kalman filter. The Nimble VR and filter output were compared using measurements performed on (1) a wooden hand model placed in various static postures and orientations; and (2) three differently sized human hands during active finger flexions. Precision and accuracy of joint angle estimates as a function of hand posture and orientation were determined. Moreover, in light of possible self-occlusions of the fingers in the Kinect camera images, data completeness was assessed. Results showed that the integration of the Data Glove through the Kalman filter provided for the proximal interphalangeal (PIP) joints of the fingers a substantial improvement of 79% in precision, from 2.2 deg to 0.9 deg. Moreover, a moderate improvement of 31% in accuracy (being the mean angular deviation from the true joint angle) was established, from 24 deg to 17 deg. The metacarpophalangeal (MCP) joint was relatively unaffected by the Kalman filter. Moreover, the Data Glove increased data completeness, thus providing a substantial advantage over the sole use of the Nimble VR system. MDPI 2015-12-15 /pmc/articles/PMC4721788/ /pubmed/26694395 http://dx.doi.org/10.3390/s151229868 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Arkenbout, Ewout A.
de Winter, Joost C. F.
Breedveld, Paul
Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements
title Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements
title_full Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements
title_fullStr Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements
title_full_unstemmed Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements
title_short Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements
title_sort robust hand motion tracking through data fusion of 5dt data glove and nimble vr kinect camera measurements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4721788/
https://www.ncbi.nlm.nih.gov/pubmed/26694395
http://dx.doi.org/10.3390/s151229868
work_keys_str_mv AT arkenboutewouta robusthandmotiontrackingthroughdatafusionof5dtdatagloveandnimblevrkinectcamerameasurements
AT dewinterjoostcf robusthandmotiontrackingthroughdatafusionof5dtdatagloveandnimblevrkinectcamerameasurements
AT breedveldpaul robusthandmotiontrackingthroughdatafusionof5dtdatagloveandnimblevrkinectcamerameasurements