Cargando…
Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements
Vision based interfaces for human computer interaction have gained increasing attention over the past decade. This study presents a data fusion approach of the Nimble VR vision based system, using the Kinect camera, with the contact based 5DT Data Glove. Data fusion was achieved through a Kalman fil...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4721788/ https://www.ncbi.nlm.nih.gov/pubmed/26694395 http://dx.doi.org/10.3390/s151229868 |
_version_ | 1782411281367564288 |
---|---|
author | Arkenbout, Ewout A. de Winter, Joost C. F. Breedveld, Paul |
author_facet | Arkenbout, Ewout A. de Winter, Joost C. F. Breedveld, Paul |
author_sort | Arkenbout, Ewout A. |
collection | PubMed |
description | Vision based interfaces for human computer interaction have gained increasing attention over the past decade. This study presents a data fusion approach of the Nimble VR vision based system, using the Kinect camera, with the contact based 5DT Data Glove. Data fusion was achieved through a Kalman filter. The Nimble VR and filter output were compared using measurements performed on (1) a wooden hand model placed in various static postures and orientations; and (2) three differently sized human hands during active finger flexions. Precision and accuracy of joint angle estimates as a function of hand posture and orientation were determined. Moreover, in light of possible self-occlusions of the fingers in the Kinect camera images, data completeness was assessed. Results showed that the integration of the Data Glove through the Kalman filter provided for the proximal interphalangeal (PIP) joints of the fingers a substantial improvement of 79% in precision, from 2.2 deg to 0.9 deg. Moreover, a moderate improvement of 31% in accuracy (being the mean angular deviation from the true joint angle) was established, from 24 deg to 17 deg. The metacarpophalangeal (MCP) joint was relatively unaffected by the Kalman filter. Moreover, the Data Glove increased data completeness, thus providing a substantial advantage over the sole use of the Nimble VR system. |
format | Online Article Text |
id | pubmed-4721788 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-47217882016-01-26 Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements Arkenbout, Ewout A. de Winter, Joost C. F. Breedveld, Paul Sensors (Basel) Article Vision based interfaces for human computer interaction have gained increasing attention over the past decade. This study presents a data fusion approach of the Nimble VR vision based system, using the Kinect camera, with the contact based 5DT Data Glove. Data fusion was achieved through a Kalman filter. The Nimble VR and filter output were compared using measurements performed on (1) a wooden hand model placed in various static postures and orientations; and (2) three differently sized human hands during active finger flexions. Precision and accuracy of joint angle estimates as a function of hand posture and orientation were determined. Moreover, in light of possible self-occlusions of the fingers in the Kinect camera images, data completeness was assessed. Results showed that the integration of the Data Glove through the Kalman filter provided for the proximal interphalangeal (PIP) joints of the fingers a substantial improvement of 79% in precision, from 2.2 deg to 0.9 deg. Moreover, a moderate improvement of 31% in accuracy (being the mean angular deviation from the true joint angle) was established, from 24 deg to 17 deg. The metacarpophalangeal (MCP) joint was relatively unaffected by the Kalman filter. Moreover, the Data Glove increased data completeness, thus providing a substantial advantage over the sole use of the Nimble VR system. MDPI 2015-12-15 /pmc/articles/PMC4721788/ /pubmed/26694395 http://dx.doi.org/10.3390/s151229868 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Arkenbout, Ewout A. de Winter, Joost C. F. Breedveld, Paul Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements |
title | Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements |
title_full | Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements |
title_fullStr | Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements |
title_full_unstemmed | Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements |
title_short | Robust Hand Motion Tracking through Data Fusion of 5DT Data Glove and Nimble VR Kinect Camera Measurements |
title_sort | robust hand motion tracking through data fusion of 5dt data glove and nimble vr kinect camera measurements |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4721788/ https://www.ncbi.nlm.nih.gov/pubmed/26694395 http://dx.doi.org/10.3390/s151229868 |
work_keys_str_mv | AT arkenboutewouta robusthandmotiontrackingthroughdatafusionof5dtdatagloveandnimblevrkinectcamerameasurements AT dewinterjoostcf robusthandmotiontrackingthroughdatafusionof5dtdatagloveandnimblevrkinectcamerameasurements AT breedveldpaul robusthandmotiontrackingthroughdatafusionof5dtdatagloveandnimblevrkinectcamerameasurements |