Cargando…
Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow
This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4721800/ https://www.ncbi.nlm.nih.gov/pubmed/26694401 http://dx.doi.org/10.3390/s151229881 |
_version_ | 1782411284080230400 |
---|---|
author | Jiang, Peng Zhao, Shuai Zhu, Rong |
author_facet | Jiang, Peng Zhao, Shuai Zhu, Rong |
author_sort | Jiang, Peng |
collection | PubMed |
description | This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system. |
format | Online Article Text |
id | pubmed-4721800 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-47218002016-01-26 Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow Jiang, Peng Zhao, Shuai Zhu, Rong Sensors (Basel) Article This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system. MDPI 2015-12-15 /pmc/articles/PMC4721800/ /pubmed/26694401 http://dx.doi.org/10.3390/s151229881 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jiang, Peng Zhao, Shuai Zhu, Rong Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow |
title | Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow |
title_full | Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow |
title_fullStr | Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow |
title_full_unstemmed | Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow |
title_short | Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow |
title_sort | smart sensing strip using monolithically integrated flexible flow sensor for noninvasively monitoring respiratory flow |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4721800/ https://www.ncbi.nlm.nih.gov/pubmed/26694401 http://dx.doi.org/10.3390/s151229881 |
work_keys_str_mv | AT jiangpeng smartsensingstripusingmonolithicallyintegratedflexibleflowsensorfornoninvasivelymonitoringrespiratoryflow AT zhaoshuai smartsensingstripusingmonolithicallyintegratedflexibleflowsensorfornoninvasivelymonitoringrespiratoryflow AT zhurong smartsensingstripusingmonolithicallyintegratedflexibleflowsensorfornoninvasivelymonitoringrespiratoryflow |