Cargando…

NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification

Epilepsy is a common neurological disorder which affects 0.5–1% of the world population. Its diagnosis relies both on Electroencephalogram (EEG) findings and characteristic seizure−induced body movements − called seizure semiology. Thus, synchronous EEG and (2D)video recording systems (known as Vide...

Descripción completa

Detalles Bibliográficos
Autores principales: Cunha, João Paulo Silva, Choupina, Hugo Miguel Pereira, Rocha, Ana Patrícia, Fernandes, José Maria, Achilles, Felix, Loesch, Anna Mira, Vollmar, Christian, Hartl, Elisabeth, Noachtar, Soheyl
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4723069/
https://www.ncbi.nlm.nih.gov/pubmed/26799795
http://dx.doi.org/10.1371/journal.pone.0145669
_version_ 1782411454445518848
author Cunha, João Paulo Silva
Choupina, Hugo Miguel Pereira
Rocha, Ana Patrícia
Fernandes, José Maria
Achilles, Felix
Loesch, Anna Mira
Vollmar, Christian
Hartl, Elisabeth
Noachtar, Soheyl
author_facet Cunha, João Paulo Silva
Choupina, Hugo Miguel Pereira
Rocha, Ana Patrícia
Fernandes, José Maria
Achilles, Felix
Loesch, Anna Mira
Vollmar, Christian
Hartl, Elisabeth
Noachtar, Soheyl
author_sort Cunha, João Paulo Silva
collection PubMed
description Epilepsy is a common neurological disorder which affects 0.5–1% of the world population. Its diagnosis relies both on Electroencephalogram (EEG) findings and characteristic seizure−induced body movements − called seizure semiology. Thus, synchronous EEG and (2D)video recording systems (known as Video−EEG) are the most accurate tools for epilepsy diagnosis. Despite the establishment of several quantitative methods for EEG analysis, seizure semiology is still analyzed by visual inspection, based on epileptologists’ subjective interpretation of the movements of interest (MOIs) that occur during recorded seizures. In this contribution, we present NeuroKinect, a low-cost, easy to setup and operate solution for a novel 3Dvideo-EEG system. It is based on a RGB-D sensor (Microsoft Kinect camera) and performs 24/7 monitoring of an Epilepsy Monitoring Unit (EMU) bed. It does not require the attachment of any reflectors or sensors to the patient’s body and has a very low maintenance load. To evaluate its performance and usability, we mounted a state-of-the-art 6-camera motion-capture system and our low-cost solution over the same EMU bed. A comparative study of seizure-simulated MOIs showed an average correlation of the resulting 3D motion trajectories of 84.2%. Then, we used our system on the routine of an EMU and collected 9 different seizures where we could perform 3D kinematic analysis of 42 MOIs arising from the temporal (TLE) (n = 19) and extratemporal (ETE) brain regions (n = 23). The obtained results showed that movement displacement and movement extent discriminated both seizure MOI groups with statistically significant levels (mean = 0.15 m vs. 0.44 m, p<0.001; mean = 0.068 m(3) vs. 0.14 m(3), p<0.05, respectively). Furthermore, TLE MOIs were significantly shorter than ETE (mean = 23 seconds vs 35 seconds, p<0.01) and presented higher jerking levels (mean = 345 ms(−3) vs 172 ms(−3), p<0.05). Our newly implemented 3D approach is faster by 87.5% in extracting body motion trajectories when compared to a 2D frame by frame tracking procedure. We conclude that this new approach provides a more comfortable (both for patients and clinical professionals), simpler, faster and lower-cost procedure than previous approaches, therefore providing a reliable tool to quantitatively analyze MOI patterns of epileptic seizures in the routine of EMUs around the world. We hope this study encourages other EMUs to adopt similar approaches so that more quantitative information is used to improve epilepsy diagnosis.
format Online
Article
Text
id pubmed-4723069
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47230692016-01-30 NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification Cunha, João Paulo Silva Choupina, Hugo Miguel Pereira Rocha, Ana Patrícia Fernandes, José Maria Achilles, Felix Loesch, Anna Mira Vollmar, Christian Hartl, Elisabeth Noachtar, Soheyl PLoS One Research Article Epilepsy is a common neurological disorder which affects 0.5–1% of the world population. Its diagnosis relies both on Electroencephalogram (EEG) findings and characteristic seizure−induced body movements − called seizure semiology. Thus, synchronous EEG and (2D)video recording systems (known as Video−EEG) are the most accurate tools for epilepsy diagnosis. Despite the establishment of several quantitative methods for EEG analysis, seizure semiology is still analyzed by visual inspection, based on epileptologists’ subjective interpretation of the movements of interest (MOIs) that occur during recorded seizures. In this contribution, we present NeuroKinect, a low-cost, easy to setup and operate solution for a novel 3Dvideo-EEG system. It is based on a RGB-D sensor (Microsoft Kinect camera) and performs 24/7 monitoring of an Epilepsy Monitoring Unit (EMU) bed. It does not require the attachment of any reflectors or sensors to the patient’s body and has a very low maintenance load. To evaluate its performance and usability, we mounted a state-of-the-art 6-camera motion-capture system and our low-cost solution over the same EMU bed. A comparative study of seizure-simulated MOIs showed an average correlation of the resulting 3D motion trajectories of 84.2%. Then, we used our system on the routine of an EMU and collected 9 different seizures where we could perform 3D kinematic analysis of 42 MOIs arising from the temporal (TLE) (n = 19) and extratemporal (ETE) brain regions (n = 23). The obtained results showed that movement displacement and movement extent discriminated both seizure MOI groups with statistically significant levels (mean = 0.15 m vs. 0.44 m, p<0.001; mean = 0.068 m(3) vs. 0.14 m(3), p<0.05, respectively). Furthermore, TLE MOIs were significantly shorter than ETE (mean = 23 seconds vs 35 seconds, p<0.01) and presented higher jerking levels (mean = 345 ms(−3) vs 172 ms(−3), p<0.05). Our newly implemented 3D approach is faster by 87.5% in extracting body motion trajectories when compared to a 2D frame by frame tracking procedure. We conclude that this new approach provides a more comfortable (both for patients and clinical professionals), simpler, faster and lower-cost procedure than previous approaches, therefore providing a reliable tool to quantitatively analyze MOI patterns of epileptic seizures in the routine of EMUs around the world. We hope this study encourages other EMUs to adopt similar approaches so that more quantitative information is used to improve epilepsy diagnosis. Public Library of Science 2016-01-22 /pmc/articles/PMC4723069/ /pubmed/26799795 http://dx.doi.org/10.1371/journal.pone.0145669 Text en © 2016 Cunha et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Cunha, João Paulo Silva
Choupina, Hugo Miguel Pereira
Rocha, Ana Patrícia
Fernandes, José Maria
Achilles, Felix
Loesch, Anna Mira
Vollmar, Christian
Hartl, Elisabeth
Noachtar, Soheyl
NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification
title NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification
title_full NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification
title_fullStr NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification
title_full_unstemmed NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification
title_short NeuroKinect: A Novel Low-Cost 3Dvideo-EEG System for Epileptic Seizure Motion Quantification
title_sort neurokinect: a novel low-cost 3dvideo-eeg system for epileptic seizure motion quantification
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4723069/
https://www.ncbi.nlm.nih.gov/pubmed/26799795
http://dx.doi.org/10.1371/journal.pone.0145669
work_keys_str_mv AT cunhajoaopaulosilva neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT choupinahugomiguelpereira neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT rochaanapatricia neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT fernandesjosemaria neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT achillesfelix neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT loeschannamira neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT vollmarchristian neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT hartlelisabeth neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification
AT noachtarsoheyl neurokinectanovellowcost3dvideoeegsystemforepilepticseizuremotionquantification