Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma

Intraoperative assessment of surgical margins is critical to ensuring residual tumor does not remain in a patient. Previously, we developed a fluorescence structured illumination microscope (SIM) system with a single-shot field of view (FOV) of 2.1×1.6 mm (3.4 mm(2)) and sub-cellular resolution (4.4...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Henry L., Mueller, Jenna L., Whitley, Melodi J., Cardona, Diana M., Willett, Rebecca M., Kirsch, David G., Brown, J. Quincy, Ramanujam, Nimmi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4723137/
https://www.ncbi.nlm.nih.gov/pubmed/26799613
http://dx.doi.org/10.1371/journal.pone.0147006
_version_ 1782411465987194880
author Fu, Henry L.
Mueller, Jenna L.
Whitley, Melodi J.
Cardona, Diana M.
Willett, Rebecca M.
Kirsch, David G.
Brown, J. Quincy
Ramanujam, Nimmi
author_facet Fu, Henry L.
Mueller, Jenna L.
Whitley, Melodi J.
Cardona, Diana M.
Willett, Rebecca M.
Kirsch, David G.
Brown, J. Quincy
Ramanujam, Nimmi
author_sort Fu, Henry L.
collection PubMed
description Intraoperative assessment of surgical margins is critical to ensuring residual tumor does not remain in a patient. Previously, we developed a fluorescence structured illumination microscope (SIM) system with a single-shot field of view (FOV) of 2.1×1.6 mm (3.4 mm(2)) and sub-cellular resolution (4.4 μm). The goal of this study was to test the utility of this technology for the detection of residual disease in a genetically engineered mouse model of sarcoma. Primary soft tissue sarcomas were generated in the hindlimb and after the tumor was surgically removed, the relevant margin was stained with acridine orange (AO), a vital stain that brightly stains cell nuclei and fibrous tissues. The tissues were imaged with the SIM system with the primary goal of visualizing fluorescent features from tumor nuclei. Given the heterogeneity of the background tissue (presence of adipose tissue and muscle), an algorithm known as maximally stable extremal regions (MSER) was optimized and applied to the images to specifically segment nuclear features. A logistic regression model was used to classify a tissue site as positive or negative by calculating area fraction and shape of the segmented features that were present and the resulting receiver operator curve (ROC) was generated by varying the probability threshold. Based on the ROC curves, the model was able to classify tumor and normal tissue with 77% sensitivity and 81% specificity (Youden’s index). For an unbiased measure of the model performance, it was applied to a separate validation dataset that resulted in 73% sensitivity and 80% specificity. When this approach was applied to representative whole margins, for a tumor probability threshold of 50%, only 1.2% of all regions from the negative margin exceeded this threshold, while over 14.8% of all regions from the positive margin exceeded this threshold.
format Online
Article
Text
id pubmed-4723137
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47231372016-01-30 Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma Fu, Henry L. Mueller, Jenna L. Whitley, Melodi J. Cardona, Diana M. Willett, Rebecca M. Kirsch, David G. Brown, J. Quincy Ramanujam, Nimmi PLoS One Research Article Intraoperative assessment of surgical margins is critical to ensuring residual tumor does not remain in a patient. Previously, we developed a fluorescence structured illumination microscope (SIM) system with a single-shot field of view (FOV) of 2.1×1.6 mm (3.4 mm(2)) and sub-cellular resolution (4.4 μm). The goal of this study was to test the utility of this technology for the detection of residual disease in a genetically engineered mouse model of sarcoma. Primary soft tissue sarcomas were generated in the hindlimb and after the tumor was surgically removed, the relevant margin was stained with acridine orange (AO), a vital stain that brightly stains cell nuclei and fibrous tissues. The tissues were imaged with the SIM system with the primary goal of visualizing fluorescent features from tumor nuclei. Given the heterogeneity of the background tissue (presence of adipose tissue and muscle), an algorithm known as maximally stable extremal regions (MSER) was optimized and applied to the images to specifically segment nuclear features. A logistic regression model was used to classify a tissue site as positive or negative by calculating area fraction and shape of the segmented features that were present and the resulting receiver operator curve (ROC) was generated by varying the probability threshold. Based on the ROC curves, the model was able to classify tumor and normal tissue with 77% sensitivity and 81% specificity (Youden’s index). For an unbiased measure of the model performance, it was applied to a separate validation dataset that resulted in 73% sensitivity and 80% specificity. When this approach was applied to representative whole margins, for a tumor probability threshold of 50%, only 1.2% of all regions from the negative margin exceeded this threshold, while over 14.8% of all regions from the positive margin exceeded this threshold. Public Library of Science 2016-01-22 /pmc/articles/PMC4723137/ /pubmed/26799613 http://dx.doi.org/10.1371/journal.pone.0147006 Text en © 2016 Fu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Fu, Henry L.
Mueller, Jenna L.
Whitley, Melodi J.
Cardona, Diana M.
Willett, Rebecca M.
Kirsch, David G.
Brown, J. Quincy
Ramanujam, Nimmi
Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma
title Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma
title_full Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma
title_fullStr Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma
title_full_unstemmed Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma
title_short Structured Illumination Microscopy and a Quantitative Image Analysis for the Detection of Positive Margins in a Pre-Clinical Genetically Engineered Mouse Model of Sarcoma
title_sort structured illumination microscopy and a quantitative image analysis for the detection of positive margins in a pre-clinical genetically engineered mouse model of sarcoma
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4723137/
https://www.ncbi.nlm.nih.gov/pubmed/26799613
http://dx.doi.org/10.1371/journal.pone.0147006
work_keys_str_mv AT fuhenryl structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma
AT muellerjennal structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma
AT whitleymelodij structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma
AT cardonadianam structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma
AT willettrebeccam structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma
AT kirschdavidg structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma
AT brownjquincy structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma
AT ramanujamnimmi structuredilluminationmicroscopyandaquantitativeimageanalysisforthedetectionofpositivemarginsinapreclinicalgeneticallyengineeredmousemodelofsarcoma