Cargando…

Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials

BACKGROUND: Glass-ionomers are traditionally regarded to be inferior to resin as fissure sealants in protecting teeth from dental caries, due to their comparatively lower retention rate. Unlike low-viscosity glass-ionomers, high-viscosity glass-ionomer cements (HVGIC) are placed as sealants by press...

Descripción completa

Detalles Bibliográficos
Autores principales: Mickenautsch, Steffen, Yengopal, Veerasamy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4723148/
https://www.ncbi.nlm.nih.gov/pubmed/26799812
http://dx.doi.org/10.1371/journal.pone.0146512
_version_ 1782411468504825856
author Mickenautsch, Steffen
Yengopal, Veerasamy
author_facet Mickenautsch, Steffen
Yengopal, Veerasamy
author_sort Mickenautsch, Steffen
collection PubMed
description BACKGROUND: Glass-ionomers are traditionally regarded to be inferior to resin as fissure sealants in protecting teeth from dental caries, due to their comparatively lower retention rate. Unlike low-viscosity glass-ionomers, high-viscosity glass-ionomer cements (HVGIC) are placed as sealants by pressing the material into pits and fissures with a petroleum-jelly-coated index finger. Hence, HVGIC sealants are assumed to penetrate pits and fissures deeper, resulting in a higher material retention rate, which may increase its caries-preventive effect. METHODS: The aim of this review was to answer the question as to whether, in patients with fully erupted permanent molar teeth, HVGIC based fissure sealants are less effective to protect against dental carious lesions in occlusal pits and fissures than resin-based fissure sealants? A systematic literature search in eight databases was conducted. Heterogeneity of accepted trials and imprecision of the established evidence were assessed. Extracted sufficiently homogenous datasets were pooled by use of a random-effects meta-analysis. Internal trial validity was evaluated. The protocol of this systematic review was registered with the International Prospective Register of Systematic Reviews (PROSPERO / Nr.: CRD42015016007). RESULTS: Seven clinical trials were provisionally included for further review. Of these, one was excluded. Seven trial reports reporting on six trials were accepted. From these, 11 datasets were extracted and pooled in four meta-analyses. The results suggest no statistically significant differences after up to 48 months and borderline significant differences in favour of HVGIC sealants after 60 months (RR 0.29; 95% CI: 0.09–0.95; p = 0.04 / RD -0.07; 95% CI: -0.14, -0.01). The point estimates and upper confidence levels after 24, 36, 48 and 60 months of RR 1.36; RR 0.90; RR 0.62; RR 0.29 and 2.78; 1.67; 1.21; 0.95, respectively, further suggest a chronological trend in favour of HVGIC above resin-based sealants. The internal trial validity was judged to be low and the bias risk high for all trials. Imprecision of results was considered too high for clinical guidance. CONCLUSION: It can be concluded that: (i) Inferiority claims against HVGIC in comparison to resin-based sealants as current gold-standard are not supported by the clinical evidence; (ii) The clinical evidence suggests similar caries-preventive efficacy of HVGIC and resin-based sealants after a period of 48 months in permanent molar teeth but remains challenged by high bias risk; (iii) Evidence concerning a possible superiority of HVGIC above resin-based sealants after 60 months is poor (even if the high bias risk is disregarded) due to imprecision and requires corroboration through future research.
format Online
Article
Text
id pubmed-4723148
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47231482016-01-30 Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials Mickenautsch, Steffen Yengopal, Veerasamy PLoS One Research Article BACKGROUND: Glass-ionomers are traditionally regarded to be inferior to resin as fissure sealants in protecting teeth from dental caries, due to their comparatively lower retention rate. Unlike low-viscosity glass-ionomers, high-viscosity glass-ionomer cements (HVGIC) are placed as sealants by pressing the material into pits and fissures with a petroleum-jelly-coated index finger. Hence, HVGIC sealants are assumed to penetrate pits and fissures deeper, resulting in a higher material retention rate, which may increase its caries-preventive effect. METHODS: The aim of this review was to answer the question as to whether, in patients with fully erupted permanent molar teeth, HVGIC based fissure sealants are less effective to protect against dental carious lesions in occlusal pits and fissures than resin-based fissure sealants? A systematic literature search in eight databases was conducted. Heterogeneity of accepted trials and imprecision of the established evidence were assessed. Extracted sufficiently homogenous datasets were pooled by use of a random-effects meta-analysis. Internal trial validity was evaluated. The protocol of this systematic review was registered with the International Prospective Register of Systematic Reviews (PROSPERO / Nr.: CRD42015016007). RESULTS: Seven clinical trials were provisionally included for further review. Of these, one was excluded. Seven trial reports reporting on six trials were accepted. From these, 11 datasets were extracted and pooled in four meta-analyses. The results suggest no statistically significant differences after up to 48 months and borderline significant differences in favour of HVGIC sealants after 60 months (RR 0.29; 95% CI: 0.09–0.95; p = 0.04 / RD -0.07; 95% CI: -0.14, -0.01). The point estimates and upper confidence levels after 24, 36, 48 and 60 months of RR 1.36; RR 0.90; RR 0.62; RR 0.29 and 2.78; 1.67; 1.21; 0.95, respectively, further suggest a chronological trend in favour of HVGIC above resin-based sealants. The internal trial validity was judged to be low and the bias risk high for all trials. Imprecision of results was considered too high for clinical guidance. CONCLUSION: It can be concluded that: (i) Inferiority claims against HVGIC in comparison to resin-based sealants as current gold-standard are not supported by the clinical evidence; (ii) The clinical evidence suggests similar caries-preventive efficacy of HVGIC and resin-based sealants after a period of 48 months in permanent molar teeth but remains challenged by high bias risk; (iii) Evidence concerning a possible superiority of HVGIC above resin-based sealants after 60 months is poor (even if the high bias risk is disregarded) due to imprecision and requires corroboration through future research. Public Library of Science 2016-01-22 /pmc/articles/PMC4723148/ /pubmed/26799812 http://dx.doi.org/10.1371/journal.pone.0146512 Text en © 2016 Mickenautsch, Yengopal http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mickenautsch, Steffen
Yengopal, Veerasamy
Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials
title Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials
title_full Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials
title_fullStr Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials
title_full_unstemmed Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials
title_short Caries-Preventive Effect of High-Viscosity Glass Ionomer and Resin-Based Fissure Sealants on Permanent Teeth: A Systematic Review of Clinical Trials
title_sort caries-preventive effect of high-viscosity glass ionomer and resin-based fissure sealants on permanent teeth: a systematic review of clinical trials
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4723148/
https://www.ncbi.nlm.nih.gov/pubmed/26799812
http://dx.doi.org/10.1371/journal.pone.0146512
work_keys_str_mv AT mickenautschsteffen cariespreventiveeffectofhighviscosityglassionomerandresinbasedfissuresealantsonpermanentteethasystematicreviewofclinicaltrials
AT yengopalveerasamy cariespreventiveeffectofhighviscosityglassionomerandresinbasedfissuresealantsonpermanentteethasystematicreviewofclinicaltrials