Cargando…

Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla

The purpose of this study was to prospectively evaluate the reproducibility of the proton density fat-fraction (PDFF) of the liver using the IDEAL algorithm, a quantitative confounder-corrected chemical-shift-encoded MRI method. Data were obtained from 15 volunteers on four different days. The first...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Bing, Han, Wei, Li, Zhenhong, Zhao, Yonghua, Ge, Mingmei, Guo, Xueqing, Wu, Xinhuai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4725882/
https://www.ncbi.nlm.nih.gov/pubmed/26763303
http://dx.doi.org/10.1038/srep19339
_version_ 1782411699012239360
author Wu, Bing
Han, Wei
Li, Zhenhong
Zhao, Yonghua
Ge, Mingmei
Guo, Xueqing
Wu, Xinhuai
author_facet Wu, Bing
Han, Wei
Li, Zhenhong
Zhao, Yonghua
Ge, Mingmei
Guo, Xueqing
Wu, Xinhuai
author_sort Wu, Bing
collection PubMed
description The purpose of this study was to prospectively evaluate the reproducibility of the proton density fat-fraction (PDFF) of the liver using the IDEAL algorithm, a quantitative confounder-corrected chemical-shift-encoded MRI method. Data were obtained from 15 volunteers on four different days. The first and the third examinations were conducted on scanner one with one-week intervals, while the second and the fourth tests were performed on scanner two with same time interval. For each test, two MR scans were performed, one before and one after a meal. Regions-of-interest measurements were manually calculated to estimate the PDFF in the right and left lobes on the PDFF images. Reproducibility was measured using the intra-class correlation coefficient (ICC). The ICCs of the PDFF in the right and left lobes were 0.935 and 0.878, respectively. The intra-scanner ICCs of the right lobe before and after a meal or at a one-week interval were 0.924 and 0.953, respectively. The inter-scanner ICCs of PDFF the next day and at a one-week interval were 0.920 and 0.864, respectively. The PDFF of liver derived from IDEAL demonstrated high intra- and inter-scanner measurement reproducibility. The PDFF of the right lobe before a meal was more reproducible than after-meal measurements.
format Online
Article
Text
id pubmed-4725882
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-47258822016-01-28 Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla Wu, Bing Han, Wei Li, Zhenhong Zhao, Yonghua Ge, Mingmei Guo, Xueqing Wu, Xinhuai Sci Rep Article The purpose of this study was to prospectively evaluate the reproducibility of the proton density fat-fraction (PDFF) of the liver using the IDEAL algorithm, a quantitative confounder-corrected chemical-shift-encoded MRI method. Data were obtained from 15 volunteers on four different days. The first and the third examinations were conducted on scanner one with one-week intervals, while the second and the fourth tests were performed on scanner two with same time interval. For each test, two MR scans were performed, one before and one after a meal. Regions-of-interest measurements were manually calculated to estimate the PDFF in the right and left lobes on the PDFF images. Reproducibility was measured using the intra-class correlation coefficient (ICC). The ICCs of the PDFF in the right and left lobes were 0.935 and 0.878, respectively. The intra-scanner ICCs of the right lobe before and after a meal or at a one-week interval were 0.924 and 0.953, respectively. The inter-scanner ICCs of PDFF the next day and at a one-week interval were 0.920 and 0.864, respectively. The PDFF of liver derived from IDEAL demonstrated high intra- and inter-scanner measurement reproducibility. The PDFF of the right lobe before a meal was more reproducible than after-meal measurements. Nature Publishing Group 2016-01-14 /pmc/articles/PMC4725882/ /pubmed/26763303 http://dx.doi.org/10.1038/srep19339 Text en Copyright © 2016, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Wu, Bing
Han, Wei
Li, Zhenhong
Zhao, Yonghua
Ge, Mingmei
Guo, Xueqing
Wu, Xinhuai
Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla
title Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla
title_full Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla
title_fullStr Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla
title_full_unstemmed Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla
title_short Reproducibility of Intra- and Inter-scanner Measurements of Liver Fat Using Complex Confounder-corrected Chemical Shift Encoded MRI at 3.0 Tesla
title_sort reproducibility of intra- and inter-scanner measurements of liver fat using complex confounder-corrected chemical shift encoded mri at 3.0 tesla
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4725882/
https://www.ncbi.nlm.nih.gov/pubmed/26763303
http://dx.doi.org/10.1038/srep19339
work_keys_str_mv AT wubing reproducibilityofintraandinterscannermeasurementsofliverfatusingcomplexconfoundercorrectedchemicalshiftencodedmriat30tesla
AT hanwei reproducibilityofintraandinterscannermeasurementsofliverfatusingcomplexconfoundercorrectedchemicalshiftencodedmriat30tesla
AT lizhenhong reproducibilityofintraandinterscannermeasurementsofliverfatusingcomplexconfoundercorrectedchemicalshiftencodedmriat30tesla
AT zhaoyonghua reproducibilityofintraandinterscannermeasurementsofliverfatusingcomplexconfoundercorrectedchemicalshiftencodedmriat30tesla
AT gemingmei reproducibilityofintraandinterscannermeasurementsofliverfatusingcomplexconfoundercorrectedchemicalshiftencodedmriat30tesla
AT guoxueqing reproducibilityofintraandinterscannermeasurementsofliverfatusingcomplexconfoundercorrectedchemicalshiftencodedmriat30tesla
AT wuxinhuai reproducibilityofintraandinterscannermeasurementsofliverfatusingcomplexconfoundercorrectedchemicalshiftencodedmriat30tesla