Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending

PURPOSE: Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending (“best contrast”/BC) increases its accuracy in detecting edema and irrever...

Descripción completa

Detalles Bibliográficos
Autores principales: Bier, Georg, Bongers, Malte N., Ditt, Hendrik, Bender, Benjamin, Ernemann, Ulrike, Horger, Marius
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4726582/
https://www.ncbi.nlm.nih.gov/pubmed/26809010
http://dx.doi.org/10.1371/journal.pone.0147378
_version_ 1782411850008231936
author Bier, Georg
Bongers, Malte N.
Ditt, Hendrik
Bender, Benjamin
Ernemann, Ulrike
Horger, Marius
author_facet Bier, Georg
Bongers, Malte N.
Ditt, Hendrik
Bender, Benjamin
Ernemann, Ulrike
Horger, Marius
author_sort Bier, Georg
collection PubMed
description PURPOSE: Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending (“best contrast”/BC) increases its accuracy in detecting edema and irreversible tissue damage (infarction). METHODS: We retrospectively analyzed the NECT scans of 76 consecutive patients with ischemic stroke (exclusively middle cerebral artery territory—MCA) before and after post-processing with BC both at baseline before reperfusion therapy and at follow-up (5.73±12.74 days after stroke onset) using the Alberta Stroke Program Early CT Score (ASPECTS). We assessed the differences in ASPECTS between unprocessed and post-processed images and calculated sensitivity, specificity, and predictive values of baseline NECT using follow-up CT serving as reference standard for brain infarction. RESULTS: NECT detected brain tissue hypoattenuation in 35 of 76 patients (46.1%). This number increased to 71 patients (93.4%) after post-processing with BC. Follow-up NECT confirmed brain infarctions in 65 patients (85.5%; p = 0.012). Post-processing increased the sensitivity of NECT for brain infarction from 35/65 (54%) to 65/65 (100%), decreased its specificity from 11/11 (100%) to 7/11 (64%), its positive predictive value (PPV) from 35/35 (100%) to 65/69 (94%) and increased its accuracy 46/76 (61%) to 72/76 (95%). CONCLUSIONS: This post-hoc analysis suggests that post-processing of NECT with BC may increase its sensitivity for ischemic brain damage significantly.
format Online
Article
Text
id pubmed-4726582
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47265822016-02-03 Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending Bier, Georg Bongers, Malte N. Ditt, Hendrik Bender, Benjamin Ernemann, Ulrike Horger, Marius PLoS One Research Article PURPOSE: Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending (“best contrast”/BC) increases its accuracy in detecting edema and irreversible tissue damage (infarction). METHODS: We retrospectively analyzed the NECT scans of 76 consecutive patients with ischemic stroke (exclusively middle cerebral artery territory—MCA) before and after post-processing with BC both at baseline before reperfusion therapy and at follow-up (5.73±12.74 days after stroke onset) using the Alberta Stroke Program Early CT Score (ASPECTS). We assessed the differences in ASPECTS between unprocessed and post-processed images and calculated sensitivity, specificity, and predictive values of baseline NECT using follow-up CT serving as reference standard for brain infarction. RESULTS: NECT detected brain tissue hypoattenuation in 35 of 76 patients (46.1%). This number increased to 71 patients (93.4%) after post-processing with BC. Follow-up NECT confirmed brain infarctions in 65 patients (85.5%; p = 0.012). Post-processing increased the sensitivity of NECT for brain infarction from 35/65 (54%) to 65/65 (100%), decreased its specificity from 11/11 (100%) to 7/11 (64%), its positive predictive value (PPV) from 35/35 (100%) to 65/69 (94%) and increased its accuracy 46/76 (61%) to 72/76 (95%). CONCLUSIONS: This post-hoc analysis suggests that post-processing of NECT with BC may increase its sensitivity for ischemic brain damage significantly. Public Library of Science 2016-01-25 /pmc/articles/PMC4726582/ /pubmed/26809010 http://dx.doi.org/10.1371/journal.pone.0147378 Text en © 2016 Bier et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Bier, Georg
Bongers, Malte N.
Ditt, Hendrik
Bender, Benjamin
Ernemann, Ulrike
Horger, Marius
Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending
title Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending
title_full Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending
title_fullStr Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending
title_full_unstemmed Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending
title_short Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending
title_sort accuracy of non-enhanced ct in detecting early ischemic edema using frequency selective non-linear blending
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4726582/
https://www.ncbi.nlm.nih.gov/pubmed/26809010
http://dx.doi.org/10.1371/journal.pone.0147378
work_keys_str_mv AT biergeorg accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT bongersmalten accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT ditthendrik accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT benderbenjamin accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT ernemannulrike accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT horgermarius accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending