Cargando…
Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending
PURPOSE: Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending (“best contrast”/BC) increases its accuracy in detecting edema and irrever...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4726582/ https://www.ncbi.nlm.nih.gov/pubmed/26809010 http://dx.doi.org/10.1371/journal.pone.0147378 |
_version_ | 1782411850008231936 |
---|---|
author | Bier, Georg Bongers, Malte N. Ditt, Hendrik Bender, Benjamin Ernemann, Ulrike Horger, Marius |
author_facet | Bier, Georg Bongers, Malte N. Ditt, Hendrik Bender, Benjamin Ernemann, Ulrike Horger, Marius |
author_sort | Bier, Georg |
collection | PubMed |
description | PURPOSE: Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending (“best contrast”/BC) increases its accuracy in detecting edema and irreversible tissue damage (infarction). METHODS: We retrospectively analyzed the NECT scans of 76 consecutive patients with ischemic stroke (exclusively middle cerebral artery territory—MCA) before and after post-processing with BC both at baseline before reperfusion therapy and at follow-up (5.73±12.74 days after stroke onset) using the Alberta Stroke Program Early CT Score (ASPECTS). We assessed the differences in ASPECTS between unprocessed and post-processed images and calculated sensitivity, specificity, and predictive values of baseline NECT using follow-up CT serving as reference standard for brain infarction. RESULTS: NECT detected brain tissue hypoattenuation in 35 of 76 patients (46.1%). This number increased to 71 patients (93.4%) after post-processing with BC. Follow-up NECT confirmed brain infarctions in 65 patients (85.5%; p = 0.012). Post-processing increased the sensitivity of NECT for brain infarction from 35/65 (54%) to 65/65 (100%), decreased its specificity from 11/11 (100%) to 7/11 (64%), its positive predictive value (PPV) from 35/35 (100%) to 65/69 (94%) and increased its accuracy 46/76 (61%) to 72/76 (95%). CONCLUSIONS: This post-hoc analysis suggests that post-processing of NECT with BC may increase its sensitivity for ischemic brain damage significantly. |
format | Online Article Text |
id | pubmed-4726582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47265822016-02-03 Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending Bier, Georg Bongers, Malte N. Ditt, Hendrik Bender, Benjamin Ernemann, Ulrike Horger, Marius PLoS One Research Article PURPOSE: Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending (“best contrast”/BC) increases its accuracy in detecting edema and irreversible tissue damage (infarction). METHODS: We retrospectively analyzed the NECT scans of 76 consecutive patients with ischemic stroke (exclusively middle cerebral artery territory—MCA) before and after post-processing with BC both at baseline before reperfusion therapy and at follow-up (5.73±12.74 days after stroke onset) using the Alberta Stroke Program Early CT Score (ASPECTS). We assessed the differences in ASPECTS between unprocessed and post-processed images and calculated sensitivity, specificity, and predictive values of baseline NECT using follow-up CT serving as reference standard for brain infarction. RESULTS: NECT detected brain tissue hypoattenuation in 35 of 76 patients (46.1%). This number increased to 71 patients (93.4%) after post-processing with BC. Follow-up NECT confirmed brain infarctions in 65 patients (85.5%; p = 0.012). Post-processing increased the sensitivity of NECT for brain infarction from 35/65 (54%) to 65/65 (100%), decreased its specificity from 11/11 (100%) to 7/11 (64%), its positive predictive value (PPV) from 35/35 (100%) to 65/69 (94%) and increased its accuracy 46/76 (61%) to 72/76 (95%). CONCLUSIONS: This post-hoc analysis suggests that post-processing of NECT with BC may increase its sensitivity for ischemic brain damage significantly. Public Library of Science 2016-01-25 /pmc/articles/PMC4726582/ /pubmed/26809010 http://dx.doi.org/10.1371/journal.pone.0147378 Text en © 2016 Bier et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Bier, Georg Bongers, Malte N. Ditt, Hendrik Bender, Benjamin Ernemann, Ulrike Horger, Marius Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending |
title | Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending |
title_full | Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending |
title_fullStr | Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending |
title_full_unstemmed | Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending |
title_short | Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending |
title_sort | accuracy of non-enhanced ct in detecting early ischemic edema using frequency selective non-linear blending |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4726582/ https://www.ncbi.nlm.nih.gov/pubmed/26809010 http://dx.doi.org/10.1371/journal.pone.0147378 |
work_keys_str_mv | AT biergeorg accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending AT bongersmalten accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending AT ditthendrik accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending AT benderbenjamin accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending AT ernemannulrike accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending AT horgermarius accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending |