Cargando…
A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma
BMCL26 is a potential drug derived from nimesulide, which has exhibited the substantial anti-parasitic activity in various cell lines. To conduct various pharmacological and toxicological properties of this drug, we developed and validated a rapid LC-MS/MS method for its quantification in accordance...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4727756/ https://www.ncbi.nlm.nih.gov/pubmed/26823991 http://dx.doi.org/10.4172/2155-9872.1000266 |
_version_ | 1782412015840526336 |
---|---|
author | Voggu, Ramakrishna R Zhou, Xiang Su, Bin Guo, Baochuan |
author_facet | Voggu, Ramakrishna R Zhou, Xiang Su, Bin Guo, Baochuan |
author_sort | Voggu, Ramakrishna R |
collection | PubMed |
description | BMCL26 is a potential drug derived from nimesulide, which has exhibited the substantial anti-parasitic activity in various cell lines. To conduct various pharmacological and toxicological properties of this drug, we developed and validated a rapid LC-MS/MS method for its quantification in accordance with the FDA guidelines. Protein precipitation with 0.1% formic acid in acetonitrile was used to extract the analytes along with the internal standard (JCC76) from rat plasma. It was found that the calibration curve of the method had an excellent linearity (r(2) ≥ 0.9993) for the analyte concentration ranging from 0.5 to 100 ng/mL with acceptable inter- and intra-assay, precision, accuracy and stability. The matrix effect and extraction recovery were in the range of 101.30–110.10% and 90.16– 105.00%, respectively. This LC-MS/MS method is simple and rapid and can be used in the future pharmaceutical studies of BMCL26. |
format | Online Article Text |
id | pubmed-4727756 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
record_format | MEDLINE/PubMed |
spelling | pubmed-47277562016-01-26 A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma Voggu, Ramakrishna R Zhou, Xiang Su, Bin Guo, Baochuan J Anal Bioanal Tech Article BMCL26 is a potential drug derived from nimesulide, which has exhibited the substantial anti-parasitic activity in various cell lines. To conduct various pharmacological and toxicological properties of this drug, we developed and validated a rapid LC-MS/MS method for its quantification in accordance with the FDA guidelines. Protein precipitation with 0.1% formic acid in acetonitrile was used to extract the analytes along with the internal standard (JCC76) from rat plasma. It was found that the calibration curve of the method had an excellent linearity (r(2) ≥ 0.9993) for the analyte concentration ranging from 0.5 to 100 ng/mL with acceptable inter- and intra-assay, precision, accuracy and stability. The matrix effect and extraction recovery were in the range of 101.30–110.10% and 90.16– 105.00%, respectively. This LC-MS/MS method is simple and rapid and can be used in the future pharmaceutical studies of BMCL26. 2015-08-15 2015-11 /pmc/articles/PMC4727756/ /pubmed/26823991 http://dx.doi.org/10.4172/2155-9872.1000266 Text en http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Article Voggu, Ramakrishna R Zhou, Xiang Su, Bin Guo, Baochuan A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma |
title | A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma |
title_full | A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma |
title_fullStr | A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma |
title_full_unstemmed | A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma |
title_short | A Simple and Rapid LC-MS/MS Method for the Determination of BMCL26 a Novel Anti-Parasitic Agent in Rat Plasma |
title_sort | simple and rapid lc-ms/ms method for the determination of bmcl26 a novel anti-parasitic agent in rat plasma |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4727756/ https://www.ncbi.nlm.nih.gov/pubmed/26823991 http://dx.doi.org/10.4172/2155-9872.1000266 |
work_keys_str_mv | AT vogguramakrishnar asimpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma AT zhouxiang asimpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma AT subin asimpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma AT guobaochuan asimpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma AT vogguramakrishnar simpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma AT zhouxiang simpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma AT subin simpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma AT guobaochuan simpleandrapidlcmsmsmethodforthedeterminationofbmcl26anovelantiparasiticagentinratplasma |