Cargando…

The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability

BACKGROUND: The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis (Edwards Lifesciences, Irvine, CA) is a low-profile version of the earlier Perimount valve that uses the ThermaFix process for enhanced calcium removal. The Magna valve has been in use since 2008, yet no publication, until...

Descripción completa

Detalles Bibliográficos
Autores principales: Loor, Gabriel, Schuster, Andres, Cruz, Vincent, Rafael, Aldo, Stewart, William J., Diaz, James, McCurry, Kenneth
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4728780/
https://www.ncbi.nlm.nih.gov/pubmed/26818795
http://dx.doi.org/10.1186/s13019-016-0412-4
_version_ 1782412177207984128
author Loor, Gabriel
Schuster, Andres
Cruz, Vincent
Rafael, Aldo
Stewart, William J.
Diaz, James
McCurry, Kenneth
author_facet Loor, Gabriel
Schuster, Andres
Cruz, Vincent
Rafael, Aldo
Stewart, William J.
Diaz, James
McCurry, Kenneth
author_sort Loor, Gabriel
collection PubMed
description BACKGROUND: The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis (Edwards Lifesciences, Irvine, CA) is a low-profile version of the earlier Perimount valve that uses the ThermaFix process for enhanced calcium removal. The Magna valve has been in use since 2008, yet no publication, until now, has verified its intermediate-term safety and efficacy. METHODS: From 2008 through 2011 (our 4-year study period), 70 Magna valves were implanted in the mitral position at a single institution (the Cleveland Clinic). Echocardiograms were prospectively interpreted. For this study, we reviewed patients’ charts; endpoints included hemodynamic measurements, in-hospital morbidity and mortality, valve-related events, resource utilization, and 5-year survival rates. RESULTS: The mean patient age was 68 years; 43 % of the patients had New York Heart Association (NYHA) class III or IV disease, and 51.4 % had moderately severe, or worse, mitral regurgitation (MR). For 43 % of the patients, the Magna valve implantation was a reoperation. For 83 %, the Magna valve implantation also included a concomitant cardiac procedure. The median survival rate was 4.7 years and 90 % of patients were free from significant structural valve degeneration at 5 years. Preoperative atrial fibrillation, ischemic MR, intraaortic balloon pump placement, cardiogenic shock, cardiac arrest, and renal failure were associated with increased mortality. Right ventricular systolic pressure decreased from 50 mmHg preoperatively to 40 mmHg postoperatively, according to our matched-pair analysis (P = 0.003). Per their final echocardiogram during our study period, 98 % of surviving patients had trivial or no MR, one patient had mild MR, and one patient had severe MR. CONCLUSIONS: Our 5-year experience indicates that the Magna valve offers excellent intermediate-term durability and substantial echocardiographic improvement; its low-profile design make it ideal for reoperations and for concomitant cardiac procedures, including valve replacement.
format Online
Article
Text
id pubmed-4728780
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47287802016-01-28 The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability Loor, Gabriel Schuster, Andres Cruz, Vincent Rafael, Aldo Stewart, William J. Diaz, James McCurry, Kenneth J Cardiothorac Surg Research Article BACKGROUND: The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis (Edwards Lifesciences, Irvine, CA) is a low-profile version of the earlier Perimount valve that uses the ThermaFix process for enhanced calcium removal. The Magna valve has been in use since 2008, yet no publication, until now, has verified its intermediate-term safety and efficacy. METHODS: From 2008 through 2011 (our 4-year study period), 70 Magna valves were implanted in the mitral position at a single institution (the Cleveland Clinic). Echocardiograms were prospectively interpreted. For this study, we reviewed patients’ charts; endpoints included hemodynamic measurements, in-hospital morbidity and mortality, valve-related events, resource utilization, and 5-year survival rates. RESULTS: The mean patient age was 68 years; 43 % of the patients had New York Heart Association (NYHA) class III or IV disease, and 51.4 % had moderately severe, or worse, mitral regurgitation (MR). For 43 % of the patients, the Magna valve implantation was a reoperation. For 83 %, the Magna valve implantation also included a concomitant cardiac procedure. The median survival rate was 4.7 years and 90 % of patients were free from significant structural valve degeneration at 5 years. Preoperative atrial fibrillation, ischemic MR, intraaortic balloon pump placement, cardiogenic shock, cardiac arrest, and renal failure were associated with increased mortality. Right ventricular systolic pressure decreased from 50 mmHg preoperatively to 40 mmHg postoperatively, according to our matched-pair analysis (P = 0.003). Per their final echocardiogram during our study period, 98 % of surviving patients had trivial or no MR, one patient had mild MR, and one patient had severe MR. CONCLUSIONS: Our 5-year experience indicates that the Magna valve offers excellent intermediate-term durability and substantial echocardiographic improvement; its low-profile design make it ideal for reoperations and for concomitant cardiac procedures, including valve replacement. BioMed Central 2016-01-27 /pmc/articles/PMC4728780/ /pubmed/26818795 http://dx.doi.org/10.1186/s13019-016-0412-4 Text en © Loor et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Loor, Gabriel
Schuster, Andres
Cruz, Vincent
Rafael, Aldo
Stewart, William J.
Diaz, James
McCurry, Kenneth
The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
title The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
title_full The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
title_fullStr The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
title_full_unstemmed The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
title_short The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
title_sort carpentier-edwards perimount magna mitral valve bioprosthesis: intermediate-term efficacy and durability
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4728780/
https://www.ncbi.nlm.nih.gov/pubmed/26818795
http://dx.doi.org/10.1186/s13019-016-0412-4
work_keys_str_mv AT loorgabriel thecarpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT schusterandres thecarpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT cruzvincent thecarpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT rafaelaldo thecarpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT stewartwilliamj thecarpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT diazjames thecarpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT mccurrykenneth thecarpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT loorgabriel carpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT schusterandres carpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT cruzvincent carpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT rafaelaldo carpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT stewartwilliamj carpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT diazjames carpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability
AT mccurrykenneth carpentieredwardsperimountmagnamitralvalvebioprosthesisintermediatetermefficacyanddurability