Cargando…

Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy

To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retr...

Descripción completa

Detalles Bibliográficos
Autores principales: Kinhikar, Rajesh Ashok, Ghadi, Yogesh G., Sahoo, Priyadarshini, Laskar, Sarbani Ghosh, Deshpande, Deepak D., Shrivastava, Shyam K., Agarwal, Jaiprakash
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4728889/
https://www.ncbi.nlm.nih.gov/pubmed/26865754
http://dx.doi.org/10.4103/0971-6203.170792
_version_ 1782412192764657664
author Kinhikar, Rajesh Ashok
Ghadi, Yogesh G.
Sahoo, Priyadarshini
Laskar, Sarbani Ghosh
Deshpande, Deepak D.
Shrivastava, Shyam K.
Agarwal, Jaiprakash
author_facet Kinhikar, Rajesh Ashok
Ghadi, Yogesh G.
Sahoo, Priyadarshini
Laskar, Sarbani Ghosh
Deshpande, Deepak D.
Shrivastava, Shyam K.
Agarwal, Jaiprakash
author_sort Kinhikar, Rajesh Ashok
collection PubMed
description To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D(2cm) was found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity.
format Online
Article
Text
id pubmed-4728889
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-47288892016-02-10 Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy Kinhikar, Rajesh Ashok Ghadi, Yogesh G. Sahoo, Priyadarshini Laskar, Sarbani Ghosh Deshpande, Deepak D. Shrivastava, Shyam K. Agarwal, Jaiprakash J Med Phys Original Article To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D(2cm) was found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4728889/ /pubmed/26865754 http://dx.doi.org/10.4103/0971-6203.170792 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kinhikar, Rajesh Ashok
Ghadi, Yogesh G.
Sahoo, Priyadarshini
Laskar, Sarbani Ghosh
Deshpande, Deepak D.
Shrivastava, Shyam K.
Agarwal, Jaiprakash
Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
title Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
title_full Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
title_fullStr Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
title_full_unstemmed Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
title_short Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
title_sort dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4728889/
https://www.ncbi.nlm.nih.gov/pubmed/26865754
http://dx.doi.org/10.4103/0971-6203.170792
work_keys_str_mv AT kinhikarrajeshashok dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy
AT ghadiyogeshg dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy
AT sahoopriyadarshini dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy
AT laskarsarbanighosh dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy
AT deshpandedeepakd dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy
AT shrivastavashyamk dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy
AT agarwaljaiprakash dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy