Cargando…
Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4728889/ https://www.ncbi.nlm.nih.gov/pubmed/26865754 http://dx.doi.org/10.4103/0971-6203.170792 |
_version_ | 1782412192764657664 |
---|---|
author | Kinhikar, Rajesh Ashok Ghadi, Yogesh G. Sahoo, Priyadarshini Laskar, Sarbani Ghosh Deshpande, Deepak D. Shrivastava, Shyam K. Agarwal, Jaiprakash |
author_facet | Kinhikar, Rajesh Ashok Ghadi, Yogesh G. Sahoo, Priyadarshini Laskar, Sarbani Ghosh Deshpande, Deepak D. Shrivastava, Shyam K. Agarwal, Jaiprakash |
author_sort | Kinhikar, Rajesh Ashok |
collection | PubMed |
description | To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D(2cm) was found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity. |
format | Online Article Text |
id | pubmed-4728889 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-47288892016-02-10 Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy Kinhikar, Rajesh Ashok Ghadi, Yogesh G. Sahoo, Priyadarshini Laskar, Sarbani Ghosh Deshpande, Deepak D. Shrivastava, Shyam K. Agarwal, Jaiprakash J Med Phys Original Article To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D(2cm) was found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4728889/ /pubmed/26865754 http://dx.doi.org/10.4103/0971-6203.170792 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Kinhikar, Rajesh Ashok Ghadi, Yogesh G. Sahoo, Priyadarshini Laskar, Sarbani Ghosh Deshpande, Deepak D. Shrivastava, Shyam K. Agarwal, Jaiprakash Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy |
title | Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy |
title_full | Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy |
title_fullStr | Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy |
title_full_unstemmed | Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy |
title_short | Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy |
title_sort | dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4728889/ https://www.ncbi.nlm.nih.gov/pubmed/26865754 http://dx.doi.org/10.4103/0971-6203.170792 |
work_keys_str_mv | AT kinhikarrajeshashok dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy AT ghadiyogeshg dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy AT sahoopriyadarshini dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy AT laskarsarbanighosh dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy AT deshpandedeepakd dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy AT shrivastavashyamk dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy AT agarwaljaiprakash dosimetriccomparisonofthreedimensionalconformalradiotherapyintensitymodulatedradiotherapyandhelicaltomotherapyforlungstereotacticbodyradiotherapy |