Cargando…

Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial

BACKGROUND: The use of an implantable cardioverter defibrillator (ICD) is a widely used and effective therapy, which reduces the risk of cardiac death in many cardiac diseases, both implanted for secondary and primary prevention. However, recurrent arrhythmias and ICD discharges have adverse prognos...

Descripción completa

Detalles Bibliográficos
Autores principales: Futyma, Piotr, Futyma, Marian, Kułakowski, Piotr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4729177/
https://www.ncbi.nlm.nih.gov/pubmed/26818636
http://dx.doi.org/10.1186/s13063-016-1170-2
_version_ 1782412232237252608
author Futyma, Piotr
Futyma, Marian
Kułakowski, Piotr
author_facet Futyma, Piotr
Futyma, Marian
Kułakowski, Piotr
author_sort Futyma, Piotr
collection PubMed
description BACKGROUND: The use of an implantable cardioverter defibrillator (ICD) is a widely used and effective therapy, which reduces the risk of cardiac death in many cardiac diseases, both implanted for secondary and primary prevention. However, recurrent arrhythmias and ICD discharges have adverse prognostic significance. Additional parameters that would identify patients who are at increased risk of arrhythmias and appropriate ICD interventions would be of clinical value. Modern ICDs are relatively complex devices with a number of functions, including the possibility to perform noninvasive programmed stimulation (NIPS) with an implanted electrode located in the right ventricle. METHODS/DESIGN: The aim of the study is to evaluate the usefulness of NIPS in determining the likelihood of life-threatening arrhythmic events in patients with ICD. The study will include 150 consecutive patients with an ICD implanted both for primary and secondary prevention, regardless of etiology, who are followed in the outpatient clinic of our center and do not meet the exclusion criteria. A 12-step St. George’s Hospital NIPS protocol using ICD will be performed. The endpoint is to induce sustained ventricular arrhythmia (VT lasting more than 30 seconds or hemodynamically unstable VT/VF) or the end of the protocol. In case of serious and/or hemodynamically unstable heart rhythm disorders resistant to treatment with a low-energy antiarrhythmic pacing (ATP), the patient receives a short-term intravenous general anesthesia, and internal or external defibrillation is performed. Outpatient follow-up will be conducted during the pre-scheduled ICD control visits. An analysis of records of a registered memory device will be collected, a patient will be interviewed, and physical examination will be carried out. The follow-ups will be held every 3 months for 1 year. The primary endpoint of the follow-up will be appropriate intervention of ICD or sudden cardiac (arrhythmic) death; the secondary, appropriate ICD intervention, or death from cardiovascular causes; and the tertiary, appropriate ICD intervention, death or hospitalization for cardiovascular causes. DISCUSSION: It is expected that appropriate ICD interventions during follow-up will occur more often in patients who had sustained ventricular arrhythmias induced during NIPS. CLINICAL TRIALS REGISTRY: ClinicalTrials.gov, NCT02373306, date of registration: 26 February 2015.
format Online
Article
Text
id pubmed-4729177
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-47291772016-01-28 Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial Futyma, Piotr Futyma, Marian Kułakowski, Piotr Trials Study Protocol BACKGROUND: The use of an implantable cardioverter defibrillator (ICD) is a widely used and effective therapy, which reduces the risk of cardiac death in many cardiac diseases, both implanted for secondary and primary prevention. However, recurrent arrhythmias and ICD discharges have adverse prognostic significance. Additional parameters that would identify patients who are at increased risk of arrhythmias and appropriate ICD interventions would be of clinical value. Modern ICDs are relatively complex devices with a number of functions, including the possibility to perform noninvasive programmed stimulation (NIPS) with an implanted electrode located in the right ventricle. METHODS/DESIGN: The aim of the study is to evaluate the usefulness of NIPS in determining the likelihood of life-threatening arrhythmic events in patients with ICD. The study will include 150 consecutive patients with an ICD implanted both for primary and secondary prevention, regardless of etiology, who are followed in the outpatient clinic of our center and do not meet the exclusion criteria. A 12-step St. George’s Hospital NIPS protocol using ICD will be performed. The endpoint is to induce sustained ventricular arrhythmia (VT lasting more than 30 seconds or hemodynamically unstable VT/VF) or the end of the protocol. In case of serious and/or hemodynamically unstable heart rhythm disorders resistant to treatment with a low-energy antiarrhythmic pacing (ATP), the patient receives a short-term intravenous general anesthesia, and internal or external defibrillation is performed. Outpatient follow-up will be conducted during the pre-scheduled ICD control visits. An analysis of records of a registered memory device will be collected, a patient will be interviewed, and physical examination will be carried out. The follow-ups will be held every 3 months for 1 year. The primary endpoint of the follow-up will be appropriate intervention of ICD or sudden cardiac (arrhythmic) death; the secondary, appropriate ICD intervention, or death from cardiovascular causes; and the tertiary, appropriate ICD intervention, death or hospitalization for cardiovascular causes. DISCUSSION: It is expected that appropriate ICD interventions during follow-up will occur more often in patients who had sustained ventricular arrhythmias induced during NIPS. CLINICAL TRIALS REGISTRY: ClinicalTrials.gov, NCT02373306, date of registration: 26 February 2015. BioMed Central 2016-01-27 /pmc/articles/PMC4729177/ /pubmed/26818636 http://dx.doi.org/10.1186/s13063-016-1170-2 Text en © Futyma et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Study Protocol
Futyma, Piotr
Futyma, Marian
Kułakowski, Piotr
Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial
title Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial
title_full Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial
title_fullStr Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial
title_full_unstemmed Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial
title_short Non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the NIPS-ICD study): study protocol for a randomized controlled trial
title_sort non-invasive programmed stimulation to identify high-risk patients with implanted cardioverter defibrillator (the nips-icd study): study protocol for a randomized controlled trial
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4729177/
https://www.ncbi.nlm.nih.gov/pubmed/26818636
http://dx.doi.org/10.1186/s13063-016-1170-2
work_keys_str_mv AT futymapiotr noninvasiveprogrammedstimulationtoidentifyhighriskpatientswithimplantedcardioverterdefibrillatorthenipsicdstudystudyprotocolforarandomizedcontrolledtrial
AT futymamarian noninvasiveprogrammedstimulationtoidentifyhighriskpatientswithimplantedcardioverterdefibrillatorthenipsicdstudystudyprotocolforarandomizedcontrolledtrial
AT kułakowskipiotr noninvasiveprogrammedstimulationtoidentifyhighriskpatientswithimplantedcardioverterdefibrillatorthenipsicdstudystudyprotocolforarandomizedcontrolledtrial