Cargando…

Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea

INTRODUCTION: Determining the etiology of acute dyspnea in emregency department (ED) patients is often difficult. Point-of-care ultrasound (POCUS) holds promise for improving immediate diagnostic accuracy (after history and physical), thus improving use of focused therapies. We evaluate the impact o...

Descripción completa

Detalles Bibliográficos
Autores principales: Mantuani, Daniel, Frazee, Bradley W., Fahimi, Jahan, Nagdev, Arun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Department of Emergency Medicine, University of California, Irvine School of Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4729418/
https://www.ncbi.nlm.nih.gov/pubmed/26823930
http://dx.doi.org/10.5811/westjem.2015.11.28525
_version_ 1782412249685557248
author Mantuani, Daniel
Frazee, Bradley W.
Fahimi, Jahan
Nagdev, Arun
author_facet Mantuani, Daniel
Frazee, Bradley W.
Fahimi, Jahan
Nagdev, Arun
author_sort Mantuani, Daniel
collection PubMed
description INTRODUCTION: Determining the etiology of acute dyspnea in emregency department (ED) patients is often difficult. Point-of-care ultrasound (POCUS) holds promise for improving immediate diagnostic accuracy (after history and physical), thus improving use of focused therapies. We evaluate the impact of a three-part POCUS exam, or “triple scan” (TS) – composed of abbreviated echocardiography, lung ultrasound and inferior vena cava (IVC) collapsibility assessment – on the treating physician’s immediate diagnostic impression. METHODS: A convenience sample of adults presenting to our urban academic ED with acute dyspnea (Emergency Severity Index 1, 2) were prospectively enrolled when investigator sonographers were available. The method for performing components of the TS has been previously described in detail. Treating physicians rated the most likely diagnosis after history and physical but before other studies (except electrocardiogram) returned. An investigator then performed TS and disclosed the results, after which most likely diagnosis was reassessed. Final diagnosis (criterion standard) was based on medical record review by expert emergency medicine faculty blinded to TS result. We compared accuracy of pre-TS and post-TS impression (primary outcome) with McNemar’s test. Test characteristics for treating physician impression were also calculated by dichotomizing acute decompensated heart failure (ADHF), chronic obstructive pulmonary disease (COPD) and pneumonia as present or absent. RESULTS: 57 patients were enrolled with the leading final diagnoses being ADHF (26%), COPD/asthma (30%), and pneumonia (28%). Overall accuracy of the treating physician’s impression increased from 53% before TS to 77% after TS (p=0.003). The post-TS impression was 100% sensitive and 84% specific for ADHF. CONCLUSION: In this small study, POCUS evaluation of the heart, lungs and IVC improved the treating physician’s immediate overall diagnostic accuracy for ADHF, COPD/asthma and pneumonia and was particularly useful to immediately exclude ADHF as the cause of acute dyspnea.
format Online
Article
Text
id pubmed-4729418
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Department of Emergency Medicine, University of California, Irvine School of Medicine
record_format MEDLINE/PubMed
spelling pubmed-47294182016-01-28 Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea Mantuani, Daniel Frazee, Bradley W. Fahimi, Jahan Nagdev, Arun West J Emerg Med Technology in Emergency Medicine INTRODUCTION: Determining the etiology of acute dyspnea in emregency department (ED) patients is often difficult. Point-of-care ultrasound (POCUS) holds promise for improving immediate diagnostic accuracy (after history and physical), thus improving use of focused therapies. We evaluate the impact of a three-part POCUS exam, or “triple scan” (TS) – composed of abbreviated echocardiography, lung ultrasound and inferior vena cava (IVC) collapsibility assessment – on the treating physician’s immediate diagnostic impression. METHODS: A convenience sample of adults presenting to our urban academic ED with acute dyspnea (Emergency Severity Index 1, 2) were prospectively enrolled when investigator sonographers were available. The method for performing components of the TS has been previously described in detail. Treating physicians rated the most likely diagnosis after history and physical but before other studies (except electrocardiogram) returned. An investigator then performed TS and disclosed the results, after which most likely diagnosis was reassessed. Final diagnosis (criterion standard) was based on medical record review by expert emergency medicine faculty blinded to TS result. We compared accuracy of pre-TS and post-TS impression (primary outcome) with McNemar’s test. Test characteristics for treating physician impression were also calculated by dichotomizing acute decompensated heart failure (ADHF), chronic obstructive pulmonary disease (COPD) and pneumonia as present or absent. RESULTS: 57 patients were enrolled with the leading final diagnoses being ADHF (26%), COPD/asthma (30%), and pneumonia (28%). Overall accuracy of the treating physician’s impression increased from 53% before TS to 77% after TS (p=0.003). The post-TS impression was 100% sensitive and 84% specific for ADHF. CONCLUSION: In this small study, POCUS evaluation of the heart, lungs and IVC improved the treating physician’s immediate overall diagnostic accuracy for ADHF, COPD/asthma and pneumonia and was particularly useful to immediately exclude ADHF as the cause of acute dyspnea. Department of Emergency Medicine, University of California, Irvine School of Medicine 2016-01 2016-01-12 /pmc/articles/PMC4729418/ /pubmed/26823930 http://dx.doi.org/10.5811/westjem.2015.11.28525 Text en Copyright © 2016 Mantuani et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) License. See: http://creativecommons.org/licenses/by/4.0/
spellingShingle Technology in Emergency Medicine
Mantuani, Daniel
Frazee, Bradley W.
Fahimi, Jahan
Nagdev, Arun
Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea
title Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea
title_full Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea
title_fullStr Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea
title_full_unstemmed Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea
title_short Point-of-Care Multi-Organ Ultrasound Improves Diagnostic Accuracy in Adults Presenting to the Emergency Department with Acute Dyspnea
title_sort point-of-care multi-organ ultrasound improves diagnostic accuracy in adults presenting to the emergency department with acute dyspnea
topic Technology in Emergency Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4729418/
https://www.ncbi.nlm.nih.gov/pubmed/26823930
http://dx.doi.org/10.5811/westjem.2015.11.28525
work_keys_str_mv AT mantuanidaniel pointofcaremultiorganultrasoundimprovesdiagnosticaccuracyinadultspresentingtotheemergencydepartmentwithacutedyspnea
AT frazeebradleyw pointofcaremultiorganultrasoundimprovesdiagnosticaccuracyinadultspresentingtotheemergencydepartmentwithacutedyspnea
AT fahimijahan pointofcaremultiorganultrasoundimprovesdiagnosticaccuracyinadultspresentingtotheemergencydepartmentwithacutedyspnea
AT nagdevarun pointofcaremultiorganultrasoundimprovesdiagnosticaccuracyinadultspresentingtotheemergencydepartmentwithacutedyspnea