Cargando…
Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System
INTRODUCTION: The advent of electroanatomical mapping (EAM) systems for pulmonary vein isolation (PVI) has dramatically decreased radiation exposure. However, the need for some fluoroscopy remains for obtaining left atrial (LA) access. The aim was to test the feasibility of fluoroscopy-free PVI in p...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4731206/ https://www.ncbi.nlm.nih.gov/pubmed/26820309 http://dx.doi.org/10.1371/journal.pone.0148059 |
_version_ | 1782412520565243904 |
---|---|
author | Kühne, Michael Knecht, Sven Mühl, Aline Reichlin, Tobias Pavlović, Nikola Kessel-Schaefer, Arnheid Kaufmann, Beat A. Schaer, Beat Sticherling, Christian Osswald, Stefan |
author_facet | Kühne, Michael Knecht, Sven Mühl, Aline Reichlin, Tobias Pavlović, Nikola Kessel-Schaefer, Arnheid Kaufmann, Beat A. Schaer, Beat Sticherling, Christian Osswald, Stefan |
author_sort | Kühne, Michael |
collection | PubMed |
description | INTRODUCTION: The advent of electroanatomical mapping (EAM) systems for pulmonary vein isolation (PVI) has dramatically decreased radiation exposure. However, the need for some fluoroscopy remains for obtaining left atrial (LA) access. The aim was to test the feasibility of fluoroscopy-free PVI in patients with atrial fibrillation (AF) and a patent foramen ovale (PFO) guided solely by an EAM system. METHODS: Consecutive patients with AF undergoing PVI and documented PFO were studied. An EAM-guided approach without fluoroscopy and ultrasound was used. After completing the map of the right atrium, the superior vena cava and the coronary sinus, a catheter pull-down to the PFO was performed allowing LA access. The map of the LA and subsequent PVI was also performed without fluoroscopy. RESULTS: 30 patients [age 61±12 years, 73% male, ejection fraction 0.64 (0.53–0.65), LA size in parasternal long axis 38±7 mm] undergoing PVI were included. The time required for right atrial mapping including transseptal crossing was 9±4 minutes. Total procedure time was 127±37 minutes. Fluoroscopy-free PVI was feasible in 26/30 (87%) patients. In four patients, fluoroscopy was needed to access (n = 3) or to re-access (n = 1) the LA. In these four patients, total fluoroscopy time was 5±3 min and the DAP was 14.9±13.4 Gy*cm(2). Single-procedure success rate was 80% (24/30) after a median follow-up of 12 months. CONCLUSION: In patients with a documented PFO, completely fluoroscopy-free PVI is feasible in the vast majority of cases. |
format | Online Article Text |
id | pubmed-4731206 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47312062016-02-04 Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System Kühne, Michael Knecht, Sven Mühl, Aline Reichlin, Tobias Pavlović, Nikola Kessel-Schaefer, Arnheid Kaufmann, Beat A. Schaer, Beat Sticherling, Christian Osswald, Stefan PLoS One Research Article INTRODUCTION: The advent of electroanatomical mapping (EAM) systems for pulmonary vein isolation (PVI) has dramatically decreased radiation exposure. However, the need for some fluoroscopy remains for obtaining left atrial (LA) access. The aim was to test the feasibility of fluoroscopy-free PVI in patients with atrial fibrillation (AF) and a patent foramen ovale (PFO) guided solely by an EAM system. METHODS: Consecutive patients with AF undergoing PVI and documented PFO were studied. An EAM-guided approach without fluoroscopy and ultrasound was used. After completing the map of the right atrium, the superior vena cava and the coronary sinus, a catheter pull-down to the PFO was performed allowing LA access. The map of the LA and subsequent PVI was also performed without fluoroscopy. RESULTS: 30 patients [age 61±12 years, 73% male, ejection fraction 0.64 (0.53–0.65), LA size in parasternal long axis 38±7 mm] undergoing PVI were included. The time required for right atrial mapping including transseptal crossing was 9±4 minutes. Total procedure time was 127±37 minutes. Fluoroscopy-free PVI was feasible in 26/30 (87%) patients. In four patients, fluoroscopy was needed to access (n = 3) or to re-access (n = 1) the LA. In these four patients, total fluoroscopy time was 5±3 min and the DAP was 14.9±13.4 Gy*cm(2). Single-procedure success rate was 80% (24/30) after a median follow-up of 12 months. CONCLUSION: In patients with a documented PFO, completely fluoroscopy-free PVI is feasible in the vast majority of cases. Public Library of Science 2016-01-28 /pmc/articles/PMC4731206/ /pubmed/26820309 http://dx.doi.org/10.1371/journal.pone.0148059 Text en © 2016 Kühne et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kühne, Michael Knecht, Sven Mühl, Aline Reichlin, Tobias Pavlović, Nikola Kessel-Schaefer, Arnheid Kaufmann, Beat A. Schaer, Beat Sticherling, Christian Osswald, Stefan Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System |
title | Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System |
title_full | Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System |
title_fullStr | Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System |
title_full_unstemmed | Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System |
title_short | Fluoroscopy-Free Pulmonary Vein Isolation in Patients with Atrial Fibrillation and a Patent Foramen Ovale Using Solely an Electroanatomic Mapping System |
title_sort | fluoroscopy-free pulmonary vein isolation in patients with atrial fibrillation and a patent foramen ovale using solely an electroanatomic mapping system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4731206/ https://www.ncbi.nlm.nih.gov/pubmed/26820309 http://dx.doi.org/10.1371/journal.pone.0148059 |
work_keys_str_mv | AT kuhnemichael fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT knechtsven fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT muhlaline fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT reichlintobias fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT pavlovicnikola fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT kesselschaeferarnheid fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT kaufmannbeata fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT schaerbeat fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT sticherlingchristian fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem AT osswaldstefan fluoroscopyfreepulmonaryveinisolationinpatientswithatrialfibrillationandapatentforamenovaleusingsolelyanelectroanatomicmappingsystem |