Cargando…

On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel

Mutations in isocitrate dehydrogenase 1 and 2 (IDH1/2) are frequently found in brain tumors, and the resulting onco–metabolite, 2–hydroxyglutarate (2HG), has been suggested to be a potential diagnostic and prognostic biomarker of the diseases. Indeed, recent studies have demonstrated the feasibility...

Descripción completa

Detalles Bibliográficos
Autores principales: Heo, Hwon, Kim, Sungjin, Lee, Hyeong Hun, Cho, Hye Rim, Xu, Wen Jun, Lee, Se-Hoon, Park, Chul-Kee, Park, Sunghyouk, Choi, Seung Hong, Kim, Hyeonjin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4731570/
https://www.ncbi.nlm.nih.gov/pubmed/26820720
http://dx.doi.org/10.1371/journal.pone.0147794
_version_ 1782412570372603904
author Heo, Hwon
Kim, Sungjin
Lee, Hyeong Hun
Cho, Hye Rim
Xu, Wen Jun
Lee, Se-Hoon
Park, Chul-Kee
Park, Sunghyouk
Choi, Seung Hong
Kim, Hyeonjin
author_facet Heo, Hwon
Kim, Sungjin
Lee, Hyeong Hun
Cho, Hye Rim
Xu, Wen Jun
Lee, Se-Hoon
Park, Chul-Kee
Park, Sunghyouk
Choi, Seung Hong
Kim, Hyeonjin
author_sort Heo, Hwon
collection PubMed
description Mutations in isocitrate dehydrogenase 1 and 2 (IDH1/2) are frequently found in brain tumors, and the resulting onco–metabolite, 2–hydroxyglutarate (2HG), has been suggested to be a potential diagnostic and prognostic biomarker of the diseases. Indeed, recent studies have demonstrated the feasibility of non–invasively detecting 2HG by using proton magnetic resonance spectroscopy (1H–MRS). Due to severe spectral overlaps of 2HG with its background metabolites and spectral baselines, however, the majority of those previous studies employed spectral editing methods with long echo times (TEs) instead of the most commonly used short TE approach with spectral fitting. Consequently, the results obtained with spectral editing methods may potentially be prone to errors resulting from substantial signal loss due to relaxation. Given that the spectral region where the main signal of 2HG resides is particularly sensitive to spectral baseline in metabolite quantification, we have investigated the impact of incorporating voxel–specifically measured baselines into the spectral basis set on the performance of the conventional short TE approach in 2HG detection in rodent models (Fisher 344 rats; n = 19) of IDH1/2 mutant–overexpressing F98 glioma at 9.4T. Metabolite spectra were acquired (SPECIAL sequence) for a tumor region and the contralateral normal region of the brain for each animal. For the estimation of spectral baselines metabolite–nulled spectra were obtained (double–inversion–recovery SPECIAL sequence) for each individual voxels. Data were post–processed with and without the measured baselines using MRUI and LCModel—the two most widely used data post–processing packages. Our results demonstrate that in–vivo detection of 2HG using the conventional short TE approach is challenging even at 9.4T. However, incorporation of voxel–specifically measured spectral baselines may potentially improve its performance. Upon more thorough validation in a larger number of animals and more importantly in human patients, the potential utility of the proposed short TE acquisition with voxel–specific baseline measurement approach in 2HG detection may need to be considered in the study design.
format Online
Article
Text
id pubmed-4731570
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47315702016-02-04 On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel Heo, Hwon Kim, Sungjin Lee, Hyeong Hun Cho, Hye Rim Xu, Wen Jun Lee, Se-Hoon Park, Chul-Kee Park, Sunghyouk Choi, Seung Hong Kim, Hyeonjin PLoS One Research Article Mutations in isocitrate dehydrogenase 1 and 2 (IDH1/2) are frequently found in brain tumors, and the resulting onco–metabolite, 2–hydroxyglutarate (2HG), has been suggested to be a potential diagnostic and prognostic biomarker of the diseases. Indeed, recent studies have demonstrated the feasibility of non–invasively detecting 2HG by using proton magnetic resonance spectroscopy (1H–MRS). Due to severe spectral overlaps of 2HG with its background metabolites and spectral baselines, however, the majority of those previous studies employed spectral editing methods with long echo times (TEs) instead of the most commonly used short TE approach with spectral fitting. Consequently, the results obtained with spectral editing methods may potentially be prone to errors resulting from substantial signal loss due to relaxation. Given that the spectral region where the main signal of 2HG resides is particularly sensitive to spectral baseline in metabolite quantification, we have investigated the impact of incorporating voxel–specifically measured baselines into the spectral basis set on the performance of the conventional short TE approach in 2HG detection in rodent models (Fisher 344 rats; n = 19) of IDH1/2 mutant–overexpressing F98 glioma at 9.4T. Metabolite spectra were acquired (SPECIAL sequence) for a tumor region and the contralateral normal region of the brain for each animal. For the estimation of spectral baselines metabolite–nulled spectra were obtained (double–inversion–recovery SPECIAL sequence) for each individual voxels. Data were post–processed with and without the measured baselines using MRUI and LCModel—the two most widely used data post–processing packages. Our results demonstrate that in–vivo detection of 2HG using the conventional short TE approach is challenging even at 9.4T. However, incorporation of voxel–specifically measured spectral baselines may potentially improve its performance. Upon more thorough validation in a larger number of animals and more importantly in human patients, the potential utility of the proposed short TE acquisition with voxel–specific baseline measurement approach in 2HG detection may need to be considered in the study design. Public Library of Science 2016-01-28 /pmc/articles/PMC4731570/ /pubmed/26820720 http://dx.doi.org/10.1371/journal.pone.0147794 Text en © 2016 Heo et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Heo, Hwon
Kim, Sungjin
Lee, Hyeong Hun
Cho, Hye Rim
Xu, Wen Jun
Lee, Se-Hoon
Park, Chul-Kee
Park, Sunghyouk
Choi, Seung Hong
Kim, Hyeonjin
On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel
title On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel
title_full On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel
title_fullStr On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel
title_full_unstemmed On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel
title_short On the Utility of Short Echo Time (TE) Single Voxel 1H–MRS in Non–Invasive Detection of 2–Hydroxyglutarate (2HG); Challenges and Potential Improvement Illustrated with Animal Models Using MRUI and LCModel
title_sort on the utility of short echo time (te) single voxel 1h–mrs in non–invasive detection of 2–hydroxyglutarate (2hg); challenges and potential improvement illustrated with animal models using mrui and lcmodel
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4731570/
https://www.ncbi.nlm.nih.gov/pubmed/26820720
http://dx.doi.org/10.1371/journal.pone.0147794
work_keys_str_mv AT heohwon ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT kimsungjin ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT leehyeonghun ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT chohyerim ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT xuwenjun ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT leesehoon ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT parkchulkee ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT parksunghyouk ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT choiseunghong ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel
AT kimhyeonjin ontheutilityofshortechotimetesinglevoxel1hmrsinnoninvasivedetectionof2hydroxyglutarate2hgchallengesandpotentialimprovementillustratedwithanimalmodelsusingmruiandlcmodel