Cargando…

Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma

In preliminary ELISA studies where released-active forms (RAF) of antibodies (Abs) to interferon-gamma (IFNg) were added to the antigen-antibody system, a statistically significant difference in absorbance signals obtained in their presence in comparison to placebo was observed. A piezoelectric immu...

Descripción completa

Detalles Bibliográficos
Autores principales: Don, Elena, Farafonova, Olga, Pokhil, Suzanna, Barykina, Darya, Nikiforova, Marina, Shulga, Darya, Borshcheva, Alena, Tarasov, Sergey, Ermolaeva, Tatyana, Epstein, Oleg
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4732129/
https://www.ncbi.nlm.nih.gov/pubmed/26791304
http://dx.doi.org/10.3390/s16010096
_version_ 1782412659962937344
author Don, Elena
Farafonova, Olga
Pokhil, Suzanna
Barykina, Darya
Nikiforova, Marina
Shulga, Darya
Borshcheva, Alena
Tarasov, Sergey
Ermolaeva, Tatyana
Epstein, Oleg
author_facet Don, Elena
Farafonova, Olga
Pokhil, Suzanna
Barykina, Darya
Nikiforova, Marina
Shulga, Darya
Borshcheva, Alena
Tarasov, Sergey
Ermolaeva, Tatyana
Epstein, Oleg
author_sort Don, Elena
collection PubMed
description In preliminary ELISA studies where released-active forms (RAF) of antibodies (Abs) to interferon-gamma (IFNg) were added to the antigen-antibody system, a statistically significant difference in absorbance signals obtained in their presence in comparison to placebo was observed. A piezoelectric immunosensor assay was developed to support these data and investigate the effects of RAF Abs to IFNg on the specific interaction between Abs to IFNg and IFNg. The experimental conditions were designed and optimal electrode coating, detection circumstances and suitable chaotropic agents for electrode regeneration were selected. The developed technique was found to provide high repeatability, intermediate precision and specificity. The difference between the analytical signals of RAF Ab samples and those of the placebo was up to 50.8%, whereas the difference between non-specific controls and the placebo was within 5%–6%. Thus, the piezoelectric immunosensor as well as ELISA has the potential to be used for detecting the effects of RAF Abs to IFNg on the antigen-antibody interaction, which might be the result of RAF’s ability to modify the affinity of IFNg to specific/related Abs.
format Online
Article
Text
id pubmed-4732129
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-47321292016-02-12 Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma Don, Elena Farafonova, Olga Pokhil, Suzanna Barykina, Darya Nikiforova, Marina Shulga, Darya Borshcheva, Alena Tarasov, Sergey Ermolaeva, Tatyana Epstein, Oleg Sensors (Basel) Article In preliminary ELISA studies where released-active forms (RAF) of antibodies (Abs) to interferon-gamma (IFNg) were added to the antigen-antibody system, a statistically significant difference in absorbance signals obtained in their presence in comparison to placebo was observed. A piezoelectric immunosensor assay was developed to support these data and investigate the effects of RAF Abs to IFNg on the specific interaction between Abs to IFNg and IFNg. The experimental conditions were designed and optimal electrode coating, detection circumstances and suitable chaotropic agents for electrode regeneration were selected. The developed technique was found to provide high repeatability, intermediate precision and specificity. The difference between the analytical signals of RAF Ab samples and those of the placebo was up to 50.8%, whereas the difference between non-specific controls and the placebo was within 5%–6%. Thus, the piezoelectric immunosensor as well as ELISA has the potential to be used for detecting the effects of RAF Abs to IFNg on the antigen-antibody interaction, which might be the result of RAF’s ability to modify the affinity of IFNg to specific/related Abs. MDPI 2016-01-20 /pmc/articles/PMC4732129/ /pubmed/26791304 http://dx.doi.org/10.3390/s16010096 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Don, Elena
Farafonova, Olga
Pokhil, Suzanna
Barykina, Darya
Nikiforova, Marina
Shulga, Darya
Borshcheva, Alena
Tarasov, Sergey
Ermolaeva, Tatyana
Epstein, Oleg
Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma
title Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma
title_full Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma
title_fullStr Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma
title_full_unstemmed Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma
title_short Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma
title_sort use of piezoelectric immunosensors for detection of interferon-gamma interaction with specific antibodies in the presence of released-active forms of antibodies to interferon-gamma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4732129/
https://www.ncbi.nlm.nih.gov/pubmed/26791304
http://dx.doi.org/10.3390/s16010096
work_keys_str_mv AT donelena useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT farafonovaolga useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT pokhilsuzanna useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT barykinadarya useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT nikiforovamarina useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT shulgadarya useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT borshchevaalena useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT tarasovsergey useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT ermolaevatatyana useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma
AT epsteinoleg useofpiezoelectricimmunosensorsfordetectionofinterferongammainteractionwithspecificantibodiesinthepresenceofreleasedactiveformsofantibodiestointerferongamma