Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population

BACKGROUND: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Jian-Lin, Zuo, Jian-Lin, Liu, Peng, Qin, Yan-Guo, Li, Xue-Zhou, Liu, Tong, Gao, Zhong-Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4733751/
https://www.ncbi.nlm.nih.gov/pubmed/26063357
http://dx.doi.org/10.4103/0366-6999.158298
_version_ 1782412850734563328
author Xiao, Jian-Lin
Zuo, Jian-Lin
Liu, Peng
Qin, Yan-Guo
Li, Xue-Zhou
Liu, Tong
Gao, Zhong-Li
author_facet Xiao, Jian-Lin
Zuo, Jian-Lin
Liu, Peng
Qin, Yan-Guo
Li, Xue-Zhou
Liu, Tong
Gao, Zhong-Li
author_sort Xiao, Jian-Lin
collection PubMed
description BACKGROUND: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC. METHODS: A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section. RESULTS: At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome. CONCLUSIONS: HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better.
format Online
Article
Text
id pubmed-4733751
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-47337512016-04-04 Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population Xiao, Jian-Lin Zuo, Jian-Lin Liu, Peng Qin, Yan-Guo Li, Xue-Zhou Liu, Tong Gao, Zhong-Li Chin Med J (Engl) Original Article BACKGROUND: Many clinical studies have been published involving the use of a high hip center (HHC), achieved good follow-up. However, there is a little anatomic guidance in the literature regarding the amount of bone stock available for initial implant coverage in this area of the ilium. The purpose of this study was to evaluate the thickness and width of the human ilium and related acetabular cup coverage for guiding acetabular component placement in HHC. METHODS: A total of 120 normal hips in 60 cases of adult patients from lower extremities computer tomographic angiography Digital Imaging and Communications in Medicine data were chosen for the study. After importing the data to the mimics software, we chose the cross sections every 5-mm increments from the rotational center of the hip to the cephalic of the ilium according the body sagittal axis, then we measured the thickness and width of the ilium for each cross section in axial plane, calculated the cup coverage at each chosen section. RESULTS: At the acetabular dome, the mean thickness and width of the ilium were 49.71 ± 4.88 mm and 38.92 ± 3.67 mm, respectively, whereas at 1 cm above the dome, decreased to 41.35 ± 5.13 and 31.13 ± 3.37 respectively, and 2 cm above the dome, decreased to 31.25 ± 4.04 and 26.65 ± 3.43, respectively. Acetabular cup averaged coverage for 40-, 50-, and 60-mm hemispheric shells, was 100%, 89%, and 44% at the acetabular dome, 100%, 43.7%, and 27.5% for 1 cm above the dome, and 37.5%, 21.9%, and 14.2% for 2 cm above the dome. CONCLUSIONS: HHC reconstructions within 1 cm above the acetabular dome will be an acceptable and smaller diameter prosthesis would be better. Medknow Publications & Media Pvt Ltd 2015-06-20 /pmc/articles/PMC4733751/ /pubmed/26063357 http://dx.doi.org/10.4103/0366-6999.158298 Text en Copyright: © 2015 Chinese Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Xiao, Jian-Lin
Zuo, Jian-Lin
Liu, Peng
Qin, Yan-Guo
Li, Xue-Zhou
Liu, Tong
Gao, Zhong-Li
Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population
title Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population
title_full Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population
title_fullStr Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population
title_full_unstemmed Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population
title_short Cross-sectional Anatomy of Ilium for Guiding Acetabular Component Placement Using High Hip Center Technique in Asian Population
title_sort cross-sectional anatomy of ilium for guiding acetabular component placement using high hip center technique in asian population
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4733751/
https://www.ncbi.nlm.nih.gov/pubmed/26063357
http://dx.doi.org/10.4103/0366-6999.158298
work_keys_str_mv AT xiaojianlin crosssectionalanatomyofiliumforguidingacetabularcomponentplacementusinghighhipcentertechniqueinasianpopulation
AT zuojianlin crosssectionalanatomyofiliumforguidingacetabularcomponentplacementusinghighhipcentertechniqueinasianpopulation
AT liupeng crosssectionalanatomyofiliumforguidingacetabularcomponentplacementusinghighhipcentertechniqueinasianpopulation
AT qinyanguo crosssectionalanatomyofiliumforguidingacetabularcomponentplacementusinghighhipcentertechniqueinasianpopulation
AT lixuezhou crosssectionalanatomyofiliumforguidingacetabularcomponentplacementusinghighhipcentertechniqueinasianpopulation
AT liutong crosssectionalanatomyofiliumforguidingacetabularcomponentplacementusinghighhipcentertechniqueinasianpopulation
AT gaozhongli crosssectionalanatomyofiliumforguidingacetabularcomponentplacementusinghighhipcentertechniqueinasianpopulation