A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus
BACKGROUND: Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, an...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4733798/ https://www.ncbi.nlm.nih.gov/pubmed/26315073 http://dx.doi.org/10.4103/0366-6999.163398 |
_version_ | 1782412861418504192 |
---|---|
author | Jin, Mei Liang, Yong-Mei Wang, Xiao-Fang Guo, Bao-Jing Zheng, Ke Gu, Yan Lyu, Zhen-Yu |
author_facet | Jin, Mei Liang, Yong-Mei Wang, Xiao-Fang Guo, Bao-Jing Zheng, Ke Gu, Yan Lyu, Zhen-Yu |
author_sort | Jin, Mei |
collection | PubMed |
description | BACKGROUND: Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. METHODS: One thousand five hundred and twenty-six patients (537 boys, 989 girls) with PDA from January 1997 to September 2014 underwent descending aortogram and transcatheter occlusion procedure. We retrospectively analyzed data of these patients, including gender, age, weight, size and morphology of PDA, and devices used in transcatheter occlusion, outcomes, and postoperational complications. RESULTS: Median age and median weight were 4.0 years (range: 0.3–52.0 years old) and 15.3 kg (range: 4.5–91.0 kg), respectively. Mean ductal diameter, aortic ductal diameter, ductal length, and pulmonary artery pressure were 3.50 ± 2.15 mm, 10.08 ± 2.46 mm, 7.49 ± 3.02 mm, and 30.21 ± 17.28 mmHg, respectively. Morphology of PDA assessed by descending aortogram was of type A in 1428 patients, type B in 6 patients, type C in 79 patients, type D in 4 patients, and type E in 9 patients according to the classification of Krichenko. Of all the 1526 patients, 1497 patients underwent transcatheter PDA closure, among which 1492 were successful. Devices used were Amplatzer duct occluder I (ADO I, 1280, 85.8%), Cook detachable coils (116, 7.8%), ADO II (ADO II, 68, 4.6%), muscular VSD occluder (12, 0.8%), and Amplatzer vascular plug (16, 1.0%). CONCLUSIONS: Excellent occlusion rates with low complication rates were achieved with all devices regardless of PDA types. With transcatheter occlusion technique and devices developing, more patients with PDA can be treated with transcatheter closure both safely and efficiently. |
format | Online Article Text |
id | pubmed-4733798 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-47337982016-04-04 A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus Jin, Mei Liang, Yong-Mei Wang, Xiao-Fang Guo, Bao-Jing Zheng, Ke Gu, Yan Lyu, Zhen-Yu Chin Med J (Engl) Original Article BACKGROUND: Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. METHODS: One thousand five hundred and twenty-six patients (537 boys, 989 girls) with PDA from January 1997 to September 2014 underwent descending aortogram and transcatheter occlusion procedure. We retrospectively analyzed data of these patients, including gender, age, weight, size and morphology of PDA, and devices used in transcatheter occlusion, outcomes, and postoperational complications. RESULTS: Median age and median weight were 4.0 years (range: 0.3–52.0 years old) and 15.3 kg (range: 4.5–91.0 kg), respectively. Mean ductal diameter, aortic ductal diameter, ductal length, and pulmonary artery pressure were 3.50 ± 2.15 mm, 10.08 ± 2.46 mm, 7.49 ± 3.02 mm, and 30.21 ± 17.28 mmHg, respectively. Morphology of PDA assessed by descending aortogram was of type A in 1428 patients, type B in 6 patients, type C in 79 patients, type D in 4 patients, and type E in 9 patients according to the classification of Krichenko. Of all the 1526 patients, 1497 patients underwent transcatheter PDA closure, among which 1492 were successful. Devices used were Amplatzer duct occluder I (ADO I, 1280, 85.8%), Cook detachable coils (116, 7.8%), ADO II (ADO II, 68, 4.6%), muscular VSD occluder (12, 0.8%), and Amplatzer vascular plug (16, 1.0%). CONCLUSIONS: Excellent occlusion rates with low complication rates were achieved with all devices regardless of PDA types. With transcatheter occlusion technique and devices developing, more patients with PDA can be treated with transcatheter closure both safely and efficiently. Medknow Publications & Media Pvt Ltd 2015-09-05 /pmc/articles/PMC4733798/ /pubmed/26315073 http://dx.doi.org/10.4103/0366-6999.163398 Text en Copyright: © 2015 Chinese Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Jin, Mei Liang, Yong-Mei Wang, Xiao-Fang Guo, Bao-Jing Zheng, Ke Gu, Yan Lyu, Zhen-Yu A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus |
title | A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus |
title_full | A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus |
title_fullStr | A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus |
title_full_unstemmed | A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus |
title_short | A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus |
title_sort | retrospective study of 1526 cases of transcatheter occlusion of patent ductus arteriosus |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4733798/ https://www.ncbi.nlm.nih.gov/pubmed/26315073 http://dx.doi.org/10.4103/0366-6999.163398 |
work_keys_str_mv | AT jinmei aretrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT liangyongmei aretrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT wangxiaofang aretrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT guobaojing aretrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT zhengke aretrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT guyan aretrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT lyuzhenyu aretrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT jinmei retrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT liangyongmei retrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT wangxiaofang retrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT guobaojing retrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT zhengke retrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT guyan retrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus AT lyuzhenyu retrospectivestudyof1526casesoftranscatheterocclusionofpatentductusarteriosus |