Cargando…

A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets

Mesterolone is a synthetic androgenic steroid indicating a weak anabolic activity. A new, simple in use, and economical TLC-densitometric method in normal phase system (NP-TLC) has been developed and validated for the identification and quantitative determination of mesterolone in bulk drug and in t...

Descripción completa

Detalles Bibliográficos
Autores principales: Dołowy, Małgorzata, Pyka-Pająk, Alina, Filip, Katarzyna, Zagrodzka, Joanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4735978/
https://www.ncbi.nlm.nih.gov/pubmed/26881196
http://dx.doi.org/10.1155/2015/230104
_version_ 1782413183232770048
author Dołowy, Małgorzata
Pyka-Pająk, Alina
Filip, Katarzyna
Zagrodzka, Joanna
author_facet Dołowy, Małgorzata
Pyka-Pająk, Alina
Filip, Katarzyna
Zagrodzka, Joanna
author_sort Dołowy, Małgorzata
collection PubMed
description Mesterolone is a synthetic androgenic steroid indicating a weak anabolic activity. A new, simple in use, and economical TLC-densitometric method in normal phase system (NP-TLC) has been developed and validated for the identification and quantitative determination of mesterolone in bulk drug and in tablet formulation. NP-TLC analysis was performed on aluminium plates precoated with silica gel 60F(254) as the stationary phase using chloroform-acetone (40 : 10, v/v) as mobile phase. Densitometric analysis was carried out at λ = 745 nm after staining with phosphomolybdic acid. These conditions were found to give visible (dark blue) spot and sharp peak, respectively, for mesterolone at R (F)  0.75 ± 0.02 and enabled satisfactory separation of mesterolone from its related substance (potential impurity). The proposed NP-TLC-densitometric method was validated for specificity, linearity, precision, accuracy, robustness, and sensitivity according to ICH guideline and other validation requirements. The limit of detection (LOD) and limit of quantification (LOQ) were 61.0 ng·spot(−1) and 184.0 ng·spot(−1), respectively. The percent content of mesterolone in marketed tablet formulation was found to be 99.40% of label claim. The developed TLC-densitometric method can be successfully used in quality control of mesterolone in bulk material and also tablet formulation.
format Online
Article
Text
id pubmed-4735978
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-47359782016-02-15 A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets Dołowy, Małgorzata Pyka-Pająk, Alina Filip, Katarzyna Zagrodzka, Joanna Biomed Res Int Research Article Mesterolone is a synthetic androgenic steroid indicating a weak anabolic activity. A new, simple in use, and economical TLC-densitometric method in normal phase system (NP-TLC) has been developed and validated for the identification and quantitative determination of mesterolone in bulk drug and in tablet formulation. NP-TLC analysis was performed on aluminium plates precoated with silica gel 60F(254) as the stationary phase using chloroform-acetone (40 : 10, v/v) as mobile phase. Densitometric analysis was carried out at λ = 745 nm after staining with phosphomolybdic acid. These conditions were found to give visible (dark blue) spot and sharp peak, respectively, for mesterolone at R (F)  0.75 ± 0.02 and enabled satisfactory separation of mesterolone from its related substance (potential impurity). The proposed NP-TLC-densitometric method was validated for specificity, linearity, precision, accuracy, robustness, and sensitivity according to ICH guideline and other validation requirements. The limit of detection (LOD) and limit of quantification (LOQ) were 61.0 ng·spot(−1) and 184.0 ng·spot(−1), respectively. The percent content of mesterolone in marketed tablet formulation was found to be 99.40% of label claim. The developed TLC-densitometric method can be successfully used in quality control of mesterolone in bulk material and also tablet formulation. Hindawi Publishing Corporation 2015 2015-12-31 /pmc/articles/PMC4735978/ /pubmed/26881196 http://dx.doi.org/10.1155/2015/230104 Text en Copyright © 2015 Małgorzata Dołowy et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Dołowy, Małgorzata
Pyka-Pająk, Alina
Filip, Katarzyna
Zagrodzka, Joanna
A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets
title A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets
title_full A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets
title_fullStr A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets
title_full_unstemmed A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets
title_short A Validated TLC-Densitometric Method for the Determination of Mesterolone in Bulk Material and in Tablets
title_sort validated tlc-densitometric method for the determination of mesterolone in bulk material and in tablets
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4735978/
https://www.ncbi.nlm.nih.gov/pubmed/26881196
http://dx.doi.org/10.1155/2015/230104
work_keys_str_mv AT dołowymałgorzata avalidatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets
AT pykapajakalina avalidatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets
AT filipkatarzyna avalidatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets
AT zagrodzkajoanna avalidatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets
AT dołowymałgorzata validatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets
AT pykapajakalina validatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets
AT filipkatarzyna validatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets
AT zagrodzkajoanna validatedtlcdensitometricmethodforthedeterminationofmesteroloneinbulkmaterialandintablets