Cargando…
Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing b...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736222/ https://www.ncbi.nlm.nih.gov/pubmed/26881086 http://dx.doi.org/10.1155/2016/4961846 |
_version_ | 1782413236304347136 |
---|---|
author | Kreuzer, Stefan W. Pourmoghaddam, Amir Leffers, Kevin J. Johnson, Clint W. Dettmer, Marius |
author_facet | Kreuzer, Stefan W. Pourmoghaddam, Amir Leffers, Kevin J. Johnson, Clint W. Dettmer, Marius |
author_sort | Kreuzer, Stefan W. |
collection | PubMed |
description | Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing based femoral component rotation with traditional anatomic landmark methods to investigate which method is more accurate in terms of alignment to the true transepicondylar axis. Thirty-one patients underwent computer-navigated total knee arthroplasty for osteoarthritis with femoral rotation established via a force sensor. During surgery, three alternative hypothetical femoral rotational alignments were assessed, based on transepicondylar axis, anterior-posterior axis, or the utilization of a posterior condyles referencing jig. Postoperative computed tomography scans were obtained to investigate rotation characteristics. Significant differences in rotation characteristics were found between rotation according to DKB and other methods (P < 0.05). Soft tissue balancing resulted in smaller deviation from anatomical epicondylar axis than any other method. 77% of operated knees were within a range of ±3° of rotation. Only between 48% and 52% of knees would have been rotated appropriately using the other methods. The current results indicate that force sensors may be valuable for establishing correct femoral rotation. |
format | Online Article Text |
id | pubmed-4736222 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47362222016-02-15 Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study Kreuzer, Stefan W. Pourmoghaddam, Amir Leffers, Kevin J. Johnson, Clint W. Dettmer, Marius Adv Orthop Research Article Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing based femoral component rotation with traditional anatomic landmark methods to investigate which method is more accurate in terms of alignment to the true transepicondylar axis. Thirty-one patients underwent computer-navigated total knee arthroplasty for osteoarthritis with femoral rotation established via a force sensor. During surgery, three alternative hypothetical femoral rotational alignments were assessed, based on transepicondylar axis, anterior-posterior axis, or the utilization of a posterior condyles referencing jig. Postoperative computed tomography scans were obtained to investigate rotation characteristics. Significant differences in rotation characteristics were found between rotation according to DKB and other methods (P < 0.05). Soft tissue balancing resulted in smaller deviation from anatomical epicondylar axis than any other method. 77% of operated knees were within a range of ±3° of rotation. Only between 48% and 52% of knees would have been rotated appropriately using the other methods. The current results indicate that force sensors may be valuable for establishing correct femoral rotation. Hindawi Publishing Corporation 2016 2016-01-04 /pmc/articles/PMC4736222/ /pubmed/26881086 http://dx.doi.org/10.1155/2016/4961846 Text en Copyright © 2016 Stefan W. Kreuzer et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Kreuzer, Stefan W. Pourmoghaddam, Amir Leffers, Kevin J. Johnson, Clint W. Dettmer, Marius Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study |
title | Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study |
title_full | Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study |
title_fullStr | Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study |
title_full_unstemmed | Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study |
title_short | Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study |
title_sort | computed tomography analysis of postsurgery femoral component rotation based on a force sensing device method versus hypothetical rotational alignment based on anatomical landmark methods: a pilot study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736222/ https://www.ncbi.nlm.nih.gov/pubmed/26881086 http://dx.doi.org/10.1155/2016/4961846 |
work_keys_str_mv | AT kreuzerstefanw computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy AT pourmoghaddamamir computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy AT lefferskevinj computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy AT johnsonclintw computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy AT dettmermarius computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy |