Cargando…

Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study

Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing b...

Descripción completa

Detalles Bibliográficos
Autores principales: Kreuzer, Stefan W., Pourmoghaddam, Amir, Leffers, Kevin J., Johnson, Clint W., Dettmer, Marius
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736222/
https://www.ncbi.nlm.nih.gov/pubmed/26881086
http://dx.doi.org/10.1155/2016/4961846
_version_ 1782413236304347136
author Kreuzer, Stefan W.
Pourmoghaddam, Amir
Leffers, Kevin J.
Johnson, Clint W.
Dettmer, Marius
author_facet Kreuzer, Stefan W.
Pourmoghaddam, Amir
Leffers, Kevin J.
Johnson, Clint W.
Dettmer, Marius
author_sort Kreuzer, Stefan W.
collection PubMed
description Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing based femoral component rotation with traditional anatomic landmark methods to investigate which method is more accurate in terms of alignment to the true transepicondylar axis. Thirty-one patients underwent computer-navigated total knee arthroplasty for osteoarthritis with femoral rotation established via a force sensor. During surgery, three alternative hypothetical femoral rotational alignments were assessed, based on transepicondylar axis, anterior-posterior axis, or the utilization of a posterior condyles referencing jig. Postoperative computed tomography scans were obtained to investigate rotation characteristics. Significant differences in rotation characteristics were found between rotation according to DKB and other methods (P < 0.05). Soft tissue balancing resulted in smaller deviation from anatomical epicondylar axis than any other method. 77% of operated knees were within a range of ±3° of rotation. Only between 48% and 52% of knees would have been rotated appropriately using the other methods. The current results indicate that force sensors may be valuable for establishing correct femoral rotation.
format Online
Article
Text
id pubmed-4736222
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-47362222016-02-15 Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study Kreuzer, Stefan W. Pourmoghaddam, Amir Leffers, Kevin J. Johnson, Clint W. Dettmer, Marius Adv Orthop Research Article Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing based femoral component rotation with traditional anatomic landmark methods to investigate which method is more accurate in terms of alignment to the true transepicondylar axis. Thirty-one patients underwent computer-navigated total knee arthroplasty for osteoarthritis with femoral rotation established via a force sensor. During surgery, three alternative hypothetical femoral rotational alignments were assessed, based on transepicondylar axis, anterior-posterior axis, or the utilization of a posterior condyles referencing jig. Postoperative computed tomography scans were obtained to investigate rotation characteristics. Significant differences in rotation characteristics were found between rotation according to DKB and other methods (P < 0.05). Soft tissue balancing resulted in smaller deviation from anatomical epicondylar axis than any other method. 77% of operated knees were within a range of ±3° of rotation. Only between 48% and 52% of knees would have been rotated appropriately using the other methods. The current results indicate that force sensors may be valuable for establishing correct femoral rotation. Hindawi Publishing Corporation 2016 2016-01-04 /pmc/articles/PMC4736222/ /pubmed/26881086 http://dx.doi.org/10.1155/2016/4961846 Text en Copyright © 2016 Stefan W. Kreuzer et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kreuzer, Stefan W.
Pourmoghaddam, Amir
Leffers, Kevin J.
Johnson, Clint W.
Dettmer, Marius
Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
title Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
title_full Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
title_fullStr Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
title_full_unstemmed Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
title_short Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
title_sort computed tomography analysis of postsurgery femoral component rotation based on a force sensing device method versus hypothetical rotational alignment based on anatomical landmark methods: a pilot study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736222/
https://www.ncbi.nlm.nih.gov/pubmed/26881086
http://dx.doi.org/10.1155/2016/4961846
work_keys_str_mv AT kreuzerstefanw computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy
AT pourmoghaddamamir computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy
AT lefferskevinj computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy
AT johnsonclintw computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy
AT dettmermarius computedtomographyanalysisofpostsurgeryfemoralcomponentrotationbasedonaforcesensingdevicemethodversushypotheticalrotationalalignmentbasedonanatomicallandmarkmethodsapilotstudy