Cargando…

Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region

The purpose of this randomized controlled study is to investigate the clinical results obtained over four years and incidence of complications associated with one- versus two-piece custom made zirconia anchorages, in single tooth implant-supported restorations of the maxillary anterior region. Sixty...

Descripción completa

Detalles Bibliográficos
Autores principales: Paolantoni, Guerino, Marenzi, Gaetano, Blasi, Andrea, Mignogna, Jolanda, Sammartino, Gilberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736230/
https://www.ncbi.nlm.nih.gov/pubmed/27027093
http://dx.doi.org/10.1155/2016/8767845
_version_ 1782413238138306560
author Paolantoni, Guerino
Marenzi, Gaetano
Blasi, Andrea
Mignogna, Jolanda
Sammartino, Gilberto
author_facet Paolantoni, Guerino
Marenzi, Gaetano
Blasi, Andrea
Mignogna, Jolanda
Sammartino, Gilberto
author_sort Paolantoni, Guerino
collection PubMed
description The purpose of this randomized controlled study is to investigate the clinical results obtained over four years and incidence of complications associated with one- versus two-piece custom made zirconia anchorages, in single tooth implant-supported restorations of the maxillary anterior region. Sixty-five patients, with a total of 74 missing maxillary teeth, were selected in the period from February 2007 to July 2010. Two different ways of custom made zirconia abutment and final prosthetic restoration were evaluated: a standard zirconia abutment associated with a pressed layer of lithium disilicate with an all-ceramic cemented restoration versus one-piece restoration with the facing porcelain fired and pressed straight to the custom made zirconia abutment. In 29 cases, the restoration consisted of an all-ceramic restoration for cementation (two pieces); in 45 cases the restoration was a screw-retained restoration (one piece). Three all-ceramic restorations broke during the observation time. Two one-piece restorations fractured after 26 months. At follow-up examination there were no significant differences between one-piece and two-piece groups regarding the PI, BI, and MBL. Awaiting studies with longer follow-up times, a careful conclusion is that zirconia anchorages for single-implant restorations seem to demonstrate good short-term technical and biological results.
format Online
Article
Text
id pubmed-4736230
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-47362302016-03-29 Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region Paolantoni, Guerino Marenzi, Gaetano Blasi, Andrea Mignogna, Jolanda Sammartino, Gilberto Biomed Res Int Clinical Study The purpose of this randomized controlled study is to investigate the clinical results obtained over four years and incidence of complications associated with one- versus two-piece custom made zirconia anchorages, in single tooth implant-supported restorations of the maxillary anterior region. Sixty-five patients, with a total of 74 missing maxillary teeth, were selected in the period from February 2007 to July 2010. Two different ways of custom made zirconia abutment and final prosthetic restoration were evaluated: a standard zirconia abutment associated with a pressed layer of lithium disilicate with an all-ceramic cemented restoration versus one-piece restoration with the facing porcelain fired and pressed straight to the custom made zirconia abutment. In 29 cases, the restoration consisted of an all-ceramic restoration for cementation (two pieces); in 45 cases the restoration was a screw-retained restoration (one piece). Three all-ceramic restorations broke during the observation time. Two one-piece restorations fractured after 26 months. At follow-up examination there were no significant differences between one-piece and two-piece groups regarding the PI, BI, and MBL. Awaiting studies with longer follow-up times, a careful conclusion is that zirconia anchorages for single-implant restorations seem to demonstrate good short-term technical and biological results. Hindawi Publishing Corporation 2016 2016-01-04 /pmc/articles/PMC4736230/ /pubmed/27027093 http://dx.doi.org/10.1155/2016/8767845 Text en Copyright © 2016 Guerino Paolantoni et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Paolantoni, Guerino
Marenzi, Gaetano
Blasi, Andrea
Mignogna, Jolanda
Sammartino, Gilberto
Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region
title Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region
title_full Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region
title_fullStr Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region
title_full_unstemmed Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region
title_short Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region
title_sort findings of a four-year randomized controlled clinical trial comparing two-piece and one-piece zirconia abutments supporting single prosthetic restorations in maxillary anterior region
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736230/
https://www.ncbi.nlm.nih.gov/pubmed/27027093
http://dx.doi.org/10.1155/2016/8767845
work_keys_str_mv AT paolantoniguerino findingsofafouryearrandomizedcontrolledclinicaltrialcomparingtwopieceandonepiecezirconiaabutmentssupportingsingleprostheticrestorationsinmaxillaryanteriorregion
AT marenzigaetano findingsofafouryearrandomizedcontrolledclinicaltrialcomparingtwopieceandonepiecezirconiaabutmentssupportingsingleprostheticrestorationsinmaxillaryanteriorregion
AT blasiandrea findingsofafouryearrandomizedcontrolledclinicaltrialcomparingtwopieceandonepiecezirconiaabutmentssupportingsingleprostheticrestorationsinmaxillaryanteriorregion
AT mignognajolanda findingsofafouryearrandomizedcontrolledclinicaltrialcomparingtwopieceandonepiecezirconiaabutmentssupportingsingleprostheticrestorationsinmaxillaryanteriorregion
AT sammartinogilberto findingsofafouryearrandomizedcontrolledclinicaltrialcomparingtwopieceandonepiecezirconiaabutmentssupportingsingleprostheticrestorationsinmaxillaryanteriorregion