Cargando…
Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty
The cementless stem Excia (B. Braun, Melsungen, Germany) implant has a rectangular cross-sectional shape with back-and-forth flanges and a plasma-sprayed, dicalcium phosphate dihydrate coating from the middle to proximal portion to increase initial fixation and early bone formation. Here, the confor...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736951/ https://www.ncbi.nlm.nih.gov/pubmed/26881087 http://dx.doi.org/10.1155/2016/8052380 |
_version_ | 1782413385833381888 |
---|---|
author | Wada, Hiroshi Mishima, Hajime Sugaya, Hisashi Nishino, Tomofumi Yamazaki, Masashi |
author_facet | Wada, Hiroshi Mishima, Hajime Sugaya, Hisashi Nishino, Tomofumi Yamazaki, Masashi |
author_sort | Wada, Hiroshi |
collection | PubMed |
description | The cementless stem Excia (B. Braun, Melsungen, Germany) implant has a rectangular cross-sectional shape with back-and-forth flanges and a plasma-sprayed, dicalcium phosphate dihydrate coating from the middle to proximal portion to increase initial fixation and early bone formation. Here, the conformity of the Excia stem to the femoral canal morphology was three-dimensionally assessed using computed tomography. Forty-three patients (45 hips) were examined after primary total hip arthroplasty with a mean follow-up of 27 ± 3 months (range: 24–36 months). Spot welds occurred at zone 2 in 16 hips and at zone 6 in 24 hips, with 83% (20/24 hips) of those occurring within 3 months after surgery. First- (n = 12 hips), second- (n = 32), and third- (n = 1) degree stress shielding were observed. The stem was typically in contact with the cortical bone in the anterolateral mid-portion (100%) and posteromedial distal portions (85%). Stress shielding did not progress, even in cases where the stems were in contact with the distal portions. The anterior flange was in contact with the bone in all cases. The stability of the mid-lateral portion with the dicalcium phosphate dihydrate coating and the anterior flange may have inhibited the progression of stress shielding beyond the second degree. |
format | Online Article Text |
id | pubmed-4736951 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47369512016-02-15 Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty Wada, Hiroshi Mishima, Hajime Sugaya, Hisashi Nishino, Tomofumi Yamazaki, Masashi Adv Orthop Research Article The cementless stem Excia (B. Braun, Melsungen, Germany) implant has a rectangular cross-sectional shape with back-and-forth flanges and a plasma-sprayed, dicalcium phosphate dihydrate coating from the middle to proximal portion to increase initial fixation and early bone formation. Here, the conformity of the Excia stem to the femoral canal morphology was three-dimensionally assessed using computed tomography. Forty-three patients (45 hips) were examined after primary total hip arthroplasty with a mean follow-up of 27 ± 3 months (range: 24–36 months). Spot welds occurred at zone 2 in 16 hips and at zone 6 in 24 hips, with 83% (20/24 hips) of those occurring within 3 months after surgery. First- (n = 12 hips), second- (n = 32), and third- (n = 1) degree stress shielding were observed. The stem was typically in contact with the cortical bone in the anterolateral mid-portion (100%) and posteromedial distal portions (85%). Stress shielding did not progress, even in cases where the stems were in contact with the distal portions. The anterior flange was in contact with the bone in all cases. The stability of the mid-lateral portion with the dicalcium phosphate dihydrate coating and the anterior flange may have inhibited the progression of stress shielding beyond the second degree. Hindawi Publishing Corporation 2016 2016-01-10 /pmc/articles/PMC4736951/ /pubmed/26881087 http://dx.doi.org/10.1155/2016/8052380 Text en Copyright © 2016 Hiroshi Wada et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Wada, Hiroshi Mishima, Hajime Sugaya, Hisashi Nishino, Tomofumi Yamazaki, Masashi Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty |
title | Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty |
title_full | Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty |
title_fullStr | Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty |
title_full_unstemmed | Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty |
title_short | Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty |
title_sort | three-dimensional analysis of the contact pattern between the cortical bone and femoral prosthesis after cementless total hip arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4736951/ https://www.ncbi.nlm.nih.gov/pubmed/26881087 http://dx.doi.org/10.1155/2016/8052380 |
work_keys_str_mv | AT wadahiroshi threedimensionalanalysisofthecontactpatternbetweenthecorticalboneandfemoralprosthesisaftercementlesstotalhiparthroplasty AT mishimahajime threedimensionalanalysisofthecontactpatternbetweenthecorticalboneandfemoralprosthesisaftercementlesstotalhiparthroplasty AT sugayahisashi threedimensionalanalysisofthecontactpatternbetweenthecorticalboneandfemoralprosthesisaftercementlesstotalhiparthroplasty AT nishinotomofumi threedimensionalanalysisofthecontactpatternbetweenthecorticalboneandfemoralprosthesisaftercementlesstotalhiparthroplasty AT yamazakimasashi threedimensionalanalysisofthecontactpatternbetweenthecorticalboneandfemoralprosthesisaftercementlesstotalhiparthroplasty |