Cargando…

Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients

Amide proton transfer (APT) imaging is a pH mapping method based on the chemical exchange saturation transfer phenomenon that has potential for penumbra identification following stroke. The majority of the literature thus far has focused on generating pH‐weighted contrast using magnetization transfe...

Descripción completa

Detalles Bibliográficos
Autores principales: Tee, Y. K., Harston, G. W. J., Blockley, N., Okell, Thomas W., Levman, J., Sheerin, F., Cellerini, M., Jezzard, P., Kennedy, J., Payne, S. J., Chappell, M. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4737232/
https://www.ncbi.nlm.nih.gov/pubmed/24913989
http://dx.doi.org/10.1002/nbm.3147
_version_ 1782413445168103424
author Tee, Y. K.
Harston, G. W. J.
Blockley, N.
Okell, Thomas W.
Levman, J.
Sheerin, F.
Cellerini, M.
Jezzard, P.
Kennedy, J.
Payne, S. J.
Chappell, M. A.
author_facet Tee, Y. K.
Harston, G. W. J.
Blockley, N.
Okell, Thomas W.
Levman, J.
Sheerin, F.
Cellerini, M.
Jezzard, P.
Kennedy, J.
Payne, S. J.
Chappell, M. A.
author_sort Tee, Y. K.
collection PubMed
description Amide proton transfer (APT) imaging is a pH mapping method based on the chemical exchange saturation transfer phenomenon that has potential for penumbra identification following stroke. The majority of the literature thus far has focused on generating pH‐weighted contrast using magnetization transfer ratio asymmetry analysis instead of quantitative pH mapping. In this study, the widely used asymmetry analysis and a model‐based analysis were both assessed on APT data collected from healthy subjects (n = 2) and hyperacute stroke patients (n = 6, median imaging time after onset = 2 hours 59 minutes). It was found that the model‐based approach was able to quantify the APT effect with the lowest variation in grey and white matter (≤ 13.8 %) and the smallest average contrast between these two tissue types (3.48 %) in the healthy volunteers. The model‐based approach also performed quantitatively better than the other measures in the hyperacute stroke patient APT data, where the quantified APT effect in the infarct core was consistently lower than in the contralateral normal appearing tissue for all the patients recruited, with the group average of the quantified APT effect being 1.5 ± 0.3 % (infarct core) and 1.9 ± 0.4 % (contralateral). Based on the fitted parameters from the model‐based analysis and a previously published pH and amide proton exchange rate relationship, quantitative pH maps for hyperacute stroke patients were generated, for the first time, using APT imaging. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.
format Online
Article
Text
id pubmed-4737232
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-47372322016-02-18 Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients Tee, Y. K. Harston, G. W. J. Blockley, N. Okell, Thomas W. Levman, J. Sheerin, F. Cellerini, M. Jezzard, P. Kennedy, J. Payne, S. J. Chappell, M. A. NMR Biomed Research Articles Amide proton transfer (APT) imaging is a pH mapping method based on the chemical exchange saturation transfer phenomenon that has potential for penumbra identification following stroke. The majority of the literature thus far has focused on generating pH‐weighted contrast using magnetization transfer ratio asymmetry analysis instead of quantitative pH mapping. In this study, the widely used asymmetry analysis and a model‐based analysis were both assessed on APT data collected from healthy subjects (n = 2) and hyperacute stroke patients (n = 6, median imaging time after onset = 2 hours 59 minutes). It was found that the model‐based approach was able to quantify the APT effect with the lowest variation in grey and white matter (≤ 13.8 %) and the smallest average contrast between these two tissue types (3.48 %) in the healthy volunteers. The model‐based approach also performed quantitatively better than the other measures in the hyperacute stroke patient APT data, where the quantified APT effect in the infarct core was consistently lower than in the contralateral normal appearing tissue for all the patients recruited, with the group average of the quantified APT effect being 1.5 ± 0.3 % (infarct core) and 1.9 ± 0.4 % (contralateral). Based on the fitted parameters from the model‐based analysis and a previously published pH and amide proton exchange rate relationship, quantitative pH maps for hyperacute stroke patients were generated, for the first time, using APT imaging. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd. John Wiley and Sons Inc. 2014-06-10 2014-09 /pmc/articles/PMC4737232/ /pubmed/24913989 http://dx.doi.org/10.1002/nbm.3147 Text en © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Tee, Y. K.
Harston, G. W. J.
Blockley, N.
Okell, Thomas W.
Levman, J.
Sheerin, F.
Cellerini, M.
Jezzard, P.
Kennedy, J.
Payne, S. J.
Chappell, M. A.
Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients
title Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients
title_full Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients
title_fullStr Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients
title_full_unstemmed Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients
title_short Comparing different analysis methods for quantifying the MRI amide proton transfer (APT) effect in hyperacute stroke patients
title_sort comparing different analysis methods for quantifying the mri amide proton transfer (apt) effect in hyperacute stroke patients
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4737232/
https://www.ncbi.nlm.nih.gov/pubmed/24913989
http://dx.doi.org/10.1002/nbm.3147
work_keys_str_mv AT teeyk comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT harstongwj comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT blockleyn comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT okellthomasw comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT levmanj comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT sheerinf comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT cellerinim comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT jezzardp comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT kennedyj comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT paynesj comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients
AT chappellma comparingdifferentanalysismethodsforquantifyingthemriamideprotontransferapteffectinhyperacutestrokepatients