Cargando…

Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers

BACKGROUND: Absolute quantification of protein biomarkers such as serum apolipoprotein A1 by both immunoassays and LC–MS can provide misleading results. RESULTS: Recombinant ApoA-1 internal standard was prepared using stable isotope labeling by amino acids in cell culture with [(13)C(6)(15)N(2)]-lys...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Qingqing, Zhang, Suhong, Guo, Lili, Busch, Christine M, Jian, Wenying, Weng, Naidong, Snyder, Nathaniel W, Rangiah, Kannan, Mesaros, Clementina, Blair, Ian A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Future Science Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4737526/
https://www.ncbi.nlm.nih.gov/pubmed/26394123
http://dx.doi.org/10.4155/bio.15.195
_version_ 1782413492648673280
author Wang, Qingqing
Zhang, Suhong
Guo, Lili
Busch, Christine M
Jian, Wenying
Weng, Naidong
Snyder, Nathaniel W
Rangiah, Kannan
Mesaros, Clementina
Blair, Ian A
author_facet Wang, Qingqing
Zhang, Suhong
Guo, Lili
Busch, Christine M
Jian, Wenying
Weng, Naidong
Snyder, Nathaniel W
Rangiah, Kannan
Mesaros, Clementina
Blair, Ian A
author_sort Wang, Qingqing
collection PubMed
description BACKGROUND: Absolute quantification of protein biomarkers such as serum apolipoprotein A1 by both immunoassays and LC–MS can provide misleading results. RESULTS: Recombinant ApoA-1 internal standard was prepared using stable isotope labeling by amino acids in cell culture with [(13)C(6)(15)N(2)]-lysine and [(13)C(9)(15)N(1)]-tyrosine in human cells. A stable isotope dilution LC–MS method for serum ApoA-1 was validated and levels analyzed for 50 nonsmokers and 50 smokers. CONCLUSION: The concentration of ApoA-1 in nonsmokers was 169.4 mg/dl with an 18.4% reduction to 138.2 mg/dl in smokers. The validated assay will have clinical utility for assessing effects of smoking cessation and therapeutic or dietary interventions in high-risk populations.
format Online
Article
Text
id pubmed-4737526
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Future Science Ltd
record_format MEDLINE/PubMed
spelling pubmed-47375262016-11-01 Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers Wang, Qingqing Zhang, Suhong Guo, Lili Busch, Christine M Jian, Wenying Weng, Naidong Snyder, Nathaniel W Rangiah, Kannan Mesaros, Clementina Blair, Ian A Bioanalysis Research Article BACKGROUND: Absolute quantification of protein biomarkers such as serum apolipoprotein A1 by both immunoassays and LC–MS can provide misleading results. RESULTS: Recombinant ApoA-1 internal standard was prepared using stable isotope labeling by amino acids in cell culture with [(13)C(6)(15)N(2)]-lysine and [(13)C(9)(15)N(1)]-tyrosine in human cells. A stable isotope dilution LC–MS method for serum ApoA-1 was validated and levels analyzed for 50 nonsmokers and 50 smokers. CONCLUSION: The concentration of ApoA-1 in nonsmokers was 169.4 mg/dl with an 18.4% reduction to 138.2 mg/dl in smokers. The validated assay will have clinical utility for assessing effects of smoking cessation and therapeutic or dietary interventions in high-risk populations. Future Science Ltd 2015-11 /pmc/articles/PMC4737526/ /pubmed/26394123 http://dx.doi.org/10.4155/bio.15.195 Text en © Ian A Blair This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 Unported License (http://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Research Article
Wang, Qingqing
Zhang, Suhong
Guo, Lili
Busch, Christine M
Jian, Wenying
Weng, Naidong
Snyder, Nathaniel W
Rangiah, Kannan
Mesaros, Clementina
Blair, Ian A
Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers
title Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers
title_full Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers
title_fullStr Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers
title_full_unstemmed Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers
title_short Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers
title_sort serum apolipoprotein a-1 quantification by lc–ms with a silac internal standard reveals reduced levels in smokers
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4737526/
https://www.ncbi.nlm.nih.gov/pubmed/26394123
http://dx.doi.org/10.4155/bio.15.195
work_keys_str_mv AT wangqingqing serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT zhangsuhong serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT guolili serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT buschchristinem serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT jianwenying serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT wengnaidong serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT snydernathanielw serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT rangiahkannan serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT mesarosclementina serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers
AT blairiana serumapolipoproteina1quantificationbylcmswithasilacinternalstandardrevealsreducedlevelsinsmokers