Cargando…

Validation and application of the personnel factor for the garment used in cleanrooms

The cleanroom environment has many potential sources of contamination, including: operators, equipment, structures, and any surface that can create particles via friction, heat, exhaust, outgassing, and static electricity charge. Operatives working in the cleanroom are the major source of particles....

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Shih-Cheng, Shiue, Angus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4738007/
https://www.ncbi.nlm.nih.gov/pubmed/26870761
http://dx.doi.org/10.1016/j.dib.2015.12.031
_version_ 1782413555086131200
author Hu, Shih-Cheng
Shiue, Angus
author_facet Hu, Shih-Cheng
Shiue, Angus
author_sort Hu, Shih-Cheng
collection PubMed
description The cleanroom environment has many potential sources of contamination, including: operators, equipment, structures, and any surface that can create particles via friction, heat, exhaust, outgassing, and static electricity charge. Operatives working in the cleanroom are the major source of particles. While cleanroom operators work, they emit millions of particles from every activity. Particles migrate up the cleanroom garment to the head and drop to the legs during cleanroom movements. Specialized textile fabrics have been used in cleanroom garments for many years. The need for this type of fabric has increased mainly due to the need to protect critical operations in cleanrooms as well as creating comfort for operators and other personnel. This study covers the general static wind-driven method, the Helmke Drum method and the dispersal chamber to measure particle penetration, shedding, and generation, in regards to the filtration efficiency of cleanroom fabrics and garments. Firstly, particle penetration is shown to increase with increasing face velocity and decreasing particle size below 1 μm. Secondly, that a recommended upper particle-size limit should be 5 µm. Using the Helmke drum test, the size distribution of particles released from the garment is shown to follow a power law distribution, with a slope of less than 1. Furthermore, the study introduces dynamic body box for testing fabrics as well as cleanroom garments. It is more practical and sensitive when compared to traditional methods and is based on a more concise technical approach. The life-time cycle performance of a typical cleanroom garment coverall is examined, particularly looking at the implications of pre-use steralization.
format Online
Article
Text
id pubmed-4738007
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-47380072016-02-11 Validation and application of the personnel factor for the garment used in cleanrooms Hu, Shih-Cheng Shiue, Angus Data Brief Data Article The cleanroom environment has many potential sources of contamination, including: operators, equipment, structures, and any surface that can create particles via friction, heat, exhaust, outgassing, and static electricity charge. Operatives working in the cleanroom are the major source of particles. While cleanroom operators work, they emit millions of particles from every activity. Particles migrate up the cleanroom garment to the head and drop to the legs during cleanroom movements. Specialized textile fabrics have been used in cleanroom garments for many years. The need for this type of fabric has increased mainly due to the need to protect critical operations in cleanrooms as well as creating comfort for operators and other personnel. This study covers the general static wind-driven method, the Helmke Drum method and the dispersal chamber to measure particle penetration, shedding, and generation, in regards to the filtration efficiency of cleanroom fabrics and garments. Firstly, particle penetration is shown to increase with increasing face velocity and decreasing particle size below 1 μm. Secondly, that a recommended upper particle-size limit should be 5 µm. Using the Helmke drum test, the size distribution of particles released from the garment is shown to follow a power law distribution, with a slope of less than 1. Furthermore, the study introduces dynamic body box for testing fabrics as well as cleanroom garments. It is more practical and sensitive when compared to traditional methods and is based on a more concise technical approach. The life-time cycle performance of a typical cleanroom garment coverall is examined, particularly looking at the implications of pre-use steralization. Elsevier 2016-01-02 /pmc/articles/PMC4738007/ /pubmed/26870761 http://dx.doi.org/10.1016/j.dib.2015.12.031 Text en © 2016 Published by Elsevier Inc. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Data Article
Hu, Shih-Cheng
Shiue, Angus
Validation and application of the personnel factor for the garment used in cleanrooms
title Validation and application of the personnel factor for the garment used in cleanrooms
title_full Validation and application of the personnel factor for the garment used in cleanrooms
title_fullStr Validation and application of the personnel factor for the garment used in cleanrooms
title_full_unstemmed Validation and application of the personnel factor for the garment used in cleanrooms
title_short Validation and application of the personnel factor for the garment used in cleanrooms
title_sort validation and application of the personnel factor for the garment used in cleanrooms
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4738007/
https://www.ncbi.nlm.nih.gov/pubmed/26870761
http://dx.doi.org/10.1016/j.dib.2015.12.031
work_keys_str_mv AT hushihcheng validationandapplicationofthepersonnelfactorforthegarmentusedincleanrooms
AT shiueangus validationandapplicationofthepersonnelfactorforthegarmentusedincleanrooms