Cargando…
Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens
BACKGROUND: To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accura...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4738217/ https://www.ncbi.nlm.nih.gov/pubmed/26311720 http://dx.doi.org/10.1177/1932296815601441 |
_version_ | 1782413569892024320 |
---|---|
author | Klonoff, David Nayberg, Irina Thonius, Marissa See, Florian Abdel-Tawab, Mona Erbstein, Frank Haak, Thomas |
author_facet | Klonoff, David Nayberg, Irina Thonius, Marissa See, Florian Abdel-Tawab, Mona Erbstein, Frank Haak, Thomas |
author_sort | Klonoff, David |
collection | PubMed |
description | BACKGROUND: To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™. METHODS: For the accuracy assessment, 60 of each of the 3 tested devices were used for the delivery of 3 different doses (1 U, half-maximal dose, and maximal dose), which were measured gravimetrically. For the injection force assessment, 20 pens of each of the 3 types were tested twice at half-maximal and once at maximal dose, at an injection speed of 6 U/s. RESULTS: All tested pens met the International Organization for Standardization (ISO) requirements for dosing accuracy, with Gla-300 SoloSTAR showing the lowest between-dose variation (greatest reproducibility) at all dose levels. Mean injection force was significantly lower for Gla-300 SoloSTAR than for the other 2 pens at both half maximal and maximal doses (P < .0271). CONCLUSION: All tested pens were accurate according to ISO criteria, and the Gla-300 SoloSTAR pen displayed the greatest reproducibility and lowest injection force of any of the 3 tested devices. |
format | Online Article Text |
id | pubmed-4738217 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-47382172016-08-26 Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens Klonoff, David Nayberg, Irina Thonius, Marissa See, Florian Abdel-Tawab, Mona Erbstein, Frank Haak, Thomas J Diabetes Sci Technol Original Articles BACKGROUND: To deliver insulin glargine 300 U/mL (Gla-300), the widely used SoloSTAR(®) pen has been modified to allow for accurate and precise delivery of required insulin units in one-third of the volume compared with insulin glargine 100 U/mL, while improving usability. Here we compare the accuracy and injection force of 3 disposable insulin pens: Gla-300 SoloSTAR(®), FlexPen(®), and KwikPen™. METHODS: For the accuracy assessment, 60 of each of the 3 tested devices were used for the delivery of 3 different doses (1 U, half-maximal dose, and maximal dose), which were measured gravimetrically. For the injection force assessment, 20 pens of each of the 3 types were tested twice at half-maximal and once at maximal dose, at an injection speed of 6 U/s. RESULTS: All tested pens met the International Organization for Standardization (ISO) requirements for dosing accuracy, with Gla-300 SoloSTAR showing the lowest between-dose variation (greatest reproducibility) at all dose levels. Mean injection force was significantly lower for Gla-300 SoloSTAR than for the other 2 pens at both half maximal and maximal doses (P < .0271). CONCLUSION: All tested pens were accurate according to ISO criteria, and the Gla-300 SoloSTAR pen displayed the greatest reproducibility and lowest injection force of any of the 3 tested devices. SAGE Publications 2015-08-26 /pmc/articles/PMC4738217/ /pubmed/26311720 http://dx.doi.org/10.1177/1932296815601441 Text en © 2015 Diabetes Technology Society http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Articles Klonoff, David Nayberg, Irina Thonius, Marissa See, Florian Abdel-Tawab, Mona Erbstein, Frank Haak, Thomas Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens |
title | Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens |
title_full | Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens |
title_fullStr | Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens |
title_full_unstemmed | Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens |
title_short | Accuracy and Injection Force of the Gla-300 Injection Device Compared With Other Commercialized Disposable Insulin Pens |
title_sort | accuracy and injection force of the gla-300 injection device compared with other commercialized disposable insulin pens |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4738217/ https://www.ncbi.nlm.nih.gov/pubmed/26311720 http://dx.doi.org/10.1177/1932296815601441 |
work_keys_str_mv | AT klonoffdavid accuracyandinjectionforceofthegla300injectiondevicecomparedwithothercommercializeddisposableinsulinpens AT naybergirina accuracyandinjectionforceofthegla300injectiondevicecomparedwithothercommercializeddisposableinsulinpens AT thoniusmarissa accuracyandinjectionforceofthegla300injectiondevicecomparedwithothercommercializeddisposableinsulinpens AT seeflorian accuracyandinjectionforceofthegla300injectiondevicecomparedwithothercommercializeddisposableinsulinpens AT abdeltawabmona accuracyandinjectionforceofthegla300injectiondevicecomparedwithothercommercializeddisposableinsulinpens AT erbsteinfrank accuracyandinjectionforceofthegla300injectiondevicecomparedwithothercommercializeddisposableinsulinpens AT haakthomas accuracyandinjectionforceofthegla300injectiondevicecomparedwithothercommercializeddisposableinsulinpens |