Cargando…
Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study
This study was designed to compare screw stabilities augmented with different volumes of PMMA and analyze relationship between screw stability and volume of PMMA and optimum volume of PMMA in different bone condition. Osteoporotic and severely osteoporotic synthetic bone blocks were divided into gro...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4739206/ https://www.ncbi.nlm.nih.gov/pubmed/26885525 http://dx.doi.org/10.1155/2016/9627504 |
_version_ | 1782413707250237440 |
---|---|
author | Liu, Da Zhang, Xiao-jun Liao, Dong-fa Zhou, Jiang-jun Li, Zhi-qiang Zhang, Bo Wang, Cai-ru Lei, Wei Kang, Xia Zheng, Wei |
author_facet | Liu, Da Zhang, Xiao-jun Liao, Dong-fa Zhou, Jiang-jun Li, Zhi-qiang Zhang, Bo Wang, Cai-ru Lei, Wei Kang, Xia Zheng, Wei |
author_sort | Liu, Da |
collection | PubMed |
description | This study was designed to compare screw stabilities augmented with different volumes of PMMA and analyze relationship between screw stability and volume of PMMA and optimum volume of PMMA in different bone condition. Osteoporotic and severely osteoporotic synthetic bone blocks were divided into groups A0-A5 and B0-B5, respectively. Different volumes of PMMA were injected in groups A0 to A5 and B0 to B5. Axial pullout tests were performed and F (max) was measured. F (max) in groups A1-A5 were all significantly higher than group A0. Except between groups A1 and A2, A3 and A4, and A4 and A5, there were significant differences on F (max) between any other two groups. F (max) in groups B1-B5 were all significantly higher than group B0. Except between groups B1 and B2, B2 and B3, and B4 and B5, there were significant differences on F (max) between any other two groups. There was significantly positive correlation between F (max) and volume of PMMA in osteoporotic and severely osteoporotic blocks. PMMA can significantly enhance pedicle screw stability in osteoporosis and severe osteoporosis. There were positive correlations between screw stability and volume of PMMA. In this study, injection of 3 mL and 4 mL PMMA was preferred in osteoporotic and severely osteoporotic blocks, respectively. |
format | Online Article Text |
id | pubmed-4739206 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47392062016-02-16 Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study Liu, Da Zhang, Xiao-jun Liao, Dong-fa Zhou, Jiang-jun Li, Zhi-qiang Zhang, Bo Wang, Cai-ru Lei, Wei Kang, Xia Zheng, Wei Biomed Res Int Research Article This study was designed to compare screw stabilities augmented with different volumes of PMMA and analyze relationship between screw stability and volume of PMMA and optimum volume of PMMA in different bone condition. Osteoporotic and severely osteoporotic synthetic bone blocks were divided into groups A0-A5 and B0-B5, respectively. Different volumes of PMMA were injected in groups A0 to A5 and B0 to B5. Axial pullout tests were performed and F (max) was measured. F (max) in groups A1-A5 were all significantly higher than group A0. Except between groups A1 and A2, A3 and A4, and A4 and A5, there were significant differences on F (max) between any other two groups. F (max) in groups B1-B5 were all significantly higher than group B0. Except between groups B1 and B2, B2 and B3, and B4 and B5, there were significant differences on F (max) between any other two groups. There was significantly positive correlation between F (max) and volume of PMMA in osteoporotic and severely osteoporotic blocks. PMMA can significantly enhance pedicle screw stability in osteoporosis and severe osteoporosis. There were positive correlations between screw stability and volume of PMMA. In this study, injection of 3 mL and 4 mL PMMA was preferred in osteoporotic and severely osteoporotic blocks, respectively. Hindawi Publishing Corporation 2016 2016-01-17 /pmc/articles/PMC4739206/ /pubmed/26885525 http://dx.doi.org/10.1155/2016/9627504 Text en Copyright © 2016 Da Liu et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Liu, Da Zhang, Xiao-jun Liao, Dong-fa Zhou, Jiang-jun Li, Zhi-qiang Zhang, Bo Wang, Cai-ru Lei, Wei Kang, Xia Zheng, Wei Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study |
title | Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study |
title_full | Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study |
title_fullStr | Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study |
title_full_unstemmed | Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study |
title_short | Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study |
title_sort | biomechanical comparison of pedicle screw augmented with different volumes of polymethylmethacrylate in osteoporotic and severely osteoporotic synthetic bone blocks in primary implantation: an experimental study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4739206/ https://www.ncbi.nlm.nih.gov/pubmed/26885525 http://dx.doi.org/10.1155/2016/9627504 |
work_keys_str_mv | AT liuda biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT zhangxiaojun biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT liaodongfa biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT zhoujiangjun biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT lizhiqiang biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT zhangbo biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT wangcairu biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT leiwei biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT kangxia biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy AT zhengwei biomechanicalcomparisonofpediclescrewaugmentedwithdifferentvolumesofpolymethylmethacrylateinosteoporoticandseverelyosteoporoticsyntheticboneblocksinprimaryimplantationanexperimentalstudy |