Cargando…
Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study
BACKGROUND: Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4739366/ https://www.ncbi.nlm.nih.gov/pubmed/26855704 http://dx.doi.org/10.4317/jced.52658 |
_version_ | 1782413734127337472 |
---|---|
author | Mirzakouchaki, Behnam Shirazi, Sajjad Sharghi, Reza Shirazi, Samaneh Moghimi, Mahsan Shahrbaf, Shirin |
author_facet | Mirzakouchaki, Behnam Shirazi, Sajjad Sharghi, Reza Shirazi, Samaneh Moghimi, Mahsan Shahrbaf, Shirin |
author_sort | Mirzakouchaki, Behnam |
collection | PubMed |
description | BACKGROUND: Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. MATERIAL AND METHODS: 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. RESULTS: The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. CONCLUSIONS: The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch. |
format | Online Article Text |
id | pubmed-4739366 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-47393662016-02-05 Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study Mirzakouchaki, Behnam Shirazi, Sajjad Sharghi, Reza Shirazi, Samaneh Moghimi, Mahsan Shahrbaf, Shirin J Clin Exp Dent Research BACKGROUND: Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. MATERIAL AND METHODS: 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. RESULTS: The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. CONCLUSIONS: The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch. Medicina Oral S.L. 2016-02-01 /pmc/articles/PMC4739366/ /pubmed/26855704 http://dx.doi.org/10.4317/jced.52658 Text en Copyright: © 2016 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Mirzakouchaki, Behnam Shirazi, Sajjad Sharghi, Reza Shirazi, Samaneh Moghimi, Mahsan Shahrbaf, Shirin Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study |
title | Shear bond strength and debonding characteristics
of metal and ceramic brackets bonded with conventional
acid-etch and self-etch primer systems: An in-vivo study |
title_full | Shear bond strength and debonding characteristics
of metal and ceramic brackets bonded with conventional
acid-etch and self-etch primer systems: An in-vivo study |
title_fullStr | Shear bond strength and debonding characteristics
of metal and ceramic brackets bonded with conventional
acid-etch and self-etch primer systems: An in-vivo study |
title_full_unstemmed | Shear bond strength and debonding characteristics
of metal and ceramic brackets bonded with conventional
acid-etch and self-etch primer systems: An in-vivo study |
title_short | Shear bond strength and debonding characteristics
of metal and ceramic brackets bonded with conventional
acid-etch and self-etch primer systems: An in-vivo study |
title_sort | shear bond strength and debonding characteristics
of metal and ceramic brackets bonded with conventional
acid-etch and self-etch primer systems: an in-vivo study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4739366/ https://www.ncbi.nlm.nih.gov/pubmed/26855704 http://dx.doi.org/10.4317/jced.52658 |
work_keys_str_mv | AT mirzakouchakibehnam shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy AT shirazisajjad shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy AT sharghireza shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy AT shirazisamaneh shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy AT moghimimahsan shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy AT shahrbafshirin shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy |