Cargando…

Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study

BACKGROUND: Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive...

Descripción completa

Detalles Bibliográficos
Autores principales: Mirzakouchaki, Behnam, Shirazi, Sajjad, Sharghi, Reza, Shirazi, Samaneh, Moghimi, Mahsan, Shahrbaf, Shirin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4739366/
https://www.ncbi.nlm.nih.gov/pubmed/26855704
http://dx.doi.org/10.4317/jced.52658
_version_ 1782413734127337472
author Mirzakouchaki, Behnam
Shirazi, Sajjad
Sharghi, Reza
Shirazi, Samaneh
Moghimi, Mahsan
Shahrbaf, Shirin
author_facet Mirzakouchaki, Behnam
Shirazi, Sajjad
Sharghi, Reza
Shirazi, Samaneh
Moghimi, Mahsan
Shahrbaf, Shirin
author_sort Mirzakouchaki, Behnam
collection PubMed
description BACKGROUND: Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. MATERIAL AND METHODS: 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. RESULTS: The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. CONCLUSIONS: The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch.
format Online
Article
Text
id pubmed-4739366
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-47393662016-02-05 Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study Mirzakouchaki, Behnam Shirazi, Sajjad Sharghi, Reza Shirazi, Samaneh Moghimi, Mahsan Shahrbaf, Shirin J Clin Exp Dent Research BACKGROUND: Different in-vitro studies have reported various results regarding shear bond strength (SBS) of orthodontic brackets when SEP technique is compared to conventional system. This in-vivo study was designed to compare the effect of conventional acid-etching and self-etching primer adhesive (SEP) systems on SBS and debonding characteristics of metal and ceramic orthodontic brackets. MATERIAL AND METHODS: 120 intact first maxillary and mandibular premolars of 30 orthodontic patients were selected and bonded with metal and ceramic brackets using conventional acid-etch or self-etch primer system. The bonded brackets were incorporated into the wire during the study period to simulate the real orthodontic treatment condition. The teeth were extracted and debonded after 30 days. The SBS, debonding characteristics and adhesive remnant indices (ARI) were determined in all groups. RESULTS: The mean SBS of metal brackets was 10.63±1.42 MPa in conventional and 9.38±1.53 MPa in SEP system, (P=0.004). No statistically significant difference was noted between conventional and SEP systems in ceramic brackets. The frequency of 1, 2 and 3 ARI scores and debonding within the adhesive were the most common among all groups. No statistically significant difference was observed regarding ARI or failure mode of debonded specimens in different brackets or bonding systems. CONCLUSIONS: The SBS of metal brackets bonded using conventional system was significantly higher than SEP system, although the SBS of SEP system was clinically acceptable. No significant difference was found between conventional and SEP systems used with ceramic brackets. Total SBS of metal brackets was significantly higher than ceramic brackets. Due to adequate SBS of SEP system in bonding the metal brackets, it can be used as an alternative for conventional system. Key words:Shear bond strength, Orthodontic brackets, Adhesive remnant index, self-etch. Medicina Oral S.L. 2016-02-01 /pmc/articles/PMC4739366/ /pubmed/26855704 http://dx.doi.org/10.4317/jced.52658 Text en Copyright: © 2016 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Mirzakouchaki, Behnam
Shirazi, Sajjad
Sharghi, Reza
Shirazi, Samaneh
Moghimi, Mahsan
Shahrbaf, Shirin
Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study
title Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study
title_full Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study
title_fullStr Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study
title_full_unstemmed Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study
title_short Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study
title_sort shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: an in-vivo study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4739366/
https://www.ncbi.nlm.nih.gov/pubmed/26855704
http://dx.doi.org/10.4317/jced.52658
work_keys_str_mv AT mirzakouchakibehnam shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy
AT shirazisajjad shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy
AT sharghireza shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy
AT shirazisamaneh shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy
AT moghimimahsan shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy
AT shahrbafshirin shearbondstrengthanddebondingcharacteristicsofmetalandceramicbracketsbondedwithconventionalacidetchandselfetchprimersystemsaninvivostudy