Cargando…

Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability

BACKGROUND: Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-co...

Descripción completa

Detalles Bibliográficos
Autores principales: Stoller, Oliver, Schindelholz, Matthias, Hunt, Kenneth J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4743938/
https://www.ncbi.nlm.nih.gov/pubmed/26849137
http://dx.doi.org/10.1371/journal.pone.0148932
_version_ 1782414412109316096
author Stoller, Oliver
Schindelholz, Matthias
Hunt, Kenneth J.
author_facet Stoller, Oliver
Schindelholz, Matthias
Hunt, Kenneth J.
author_sort Stoller, Oliver
collection PubMed
description BACKGROUND: Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. METHODS: Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSE(P)−root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. RESULTS: All criteria for feasibility were achieved. Mean V′O(2peak) was 106±9% of predicted V′O(2max) and mean HR(peak) was 99±3% of predicted HR(max). 95% of the subjects achieved at least 1 criterion for V′O(2max), and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). CONCLUSIONS: RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V′O(2max), and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training.
format Online
Article
Text
id pubmed-4743938
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47439382016-02-11 Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability Stoller, Oliver Schindelholz, Matthias Hunt, Kenneth J. PLoS One Research Article BACKGROUND: Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. METHODS: Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSE(P)−root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. RESULTS: All criteria for feasibility were achieved. Mean V′O(2peak) was 106±9% of predicted V′O(2max) and mean HR(peak) was 99±3% of predicted HR(max). 95% of the subjects achieved at least 1 criterion for V′O(2max), and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). CONCLUSIONS: RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V′O(2max), and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training. Public Library of Science 2016-02-05 /pmc/articles/PMC4743938/ /pubmed/26849137 http://dx.doi.org/10.1371/journal.pone.0148932 Text en © 2016 Stoller et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Stoller, Oliver
Schindelholz, Matthias
Hunt, Kenneth J.
Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability
title Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability
title_full Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability
title_fullStr Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability
title_full_unstemmed Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability
title_short Robot-Assisted End-Effector-Based Stair Climbing for Cardiopulmonary Exercise Testing: Feasibility, Reliability, and Repeatability
title_sort robot-assisted end-effector-based stair climbing for cardiopulmonary exercise testing: feasibility, reliability, and repeatability
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4743938/
https://www.ncbi.nlm.nih.gov/pubmed/26849137
http://dx.doi.org/10.1371/journal.pone.0148932
work_keys_str_mv AT stolleroliver robotassistedendeffectorbasedstairclimbingforcardiopulmonaryexercisetestingfeasibilityreliabilityandrepeatability
AT schindelholzmatthias robotassistedendeffectorbasedstairclimbingforcardiopulmonaryexercisetestingfeasibilityreliabilityandrepeatability
AT huntkennethj robotassistedendeffectorbasedstairclimbingforcardiopulmonaryexercisetestingfeasibilityreliabilityandrepeatability