Cargando…
Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height
OBJECTIVES: To assess the diagnostic accuracy of placental growth factor (PlGF) and ultrasound parameters to predict delivery of a small‐for‐gestational‐age (SGA) infant in women presenting with reduced symphysis–fundus height (SFH). METHODS: This was a multicenter prospective observational study re...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons, Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4744762/ https://www.ncbi.nlm.nih.gov/pubmed/25826778 http://dx.doi.org/10.1002/uog.14860 |
_version_ | 1782414527034294272 |
---|---|
author | Griffin, M. Seed, P. T. Webster, L. Myers, J. MacKillop, L. Simpson, N. Anumba, D. Khalil, A. Denbow, M. Sau, A. Hinshaw, K. von Dadelszen, P. Benton, S. Girling, J. Redman, C. W. G. Chappell, L. C. Shennan, A. H. |
author_facet | Griffin, M. Seed, P. T. Webster, L. Myers, J. MacKillop, L. Simpson, N. Anumba, D. Khalil, A. Denbow, M. Sau, A. Hinshaw, K. von Dadelszen, P. Benton, S. Girling, J. Redman, C. W. G. Chappell, L. C. Shennan, A. H. |
author_sort | Griffin, M. |
collection | PubMed |
description | OBJECTIVES: To assess the diagnostic accuracy of placental growth factor (PlGF) and ultrasound parameters to predict delivery of a small‐for‐gestational‐age (SGA) infant in women presenting with reduced symphysis–fundus height (SFH). METHODS: This was a multicenter prospective observational study recruiting 601 women with a singleton pregnancy and reduced SFH between 24 and 37 weeks' gestation across 11 sites in the UK and Canada. Plasma PlGF concentration < 5(th) centile, estimated fetal weight (EFW) < 10(th) centile, umbilical artery Doppler pulsatility index > 95(th) centile and oligohydramnios (amniotic fluid index < 5 cm) were compared as predictors for a SGA infant < 3(rd) customized birth‐weight centile and adverse perinatal outcome. Test performance statistics were calculated for all parameters in isolation and in combination. RESULTS: Of the 601 women recruited, 592 were analyzed. For predicting delivery of SGA < 3(rd) centile (n = 78), EFW < 10(th) centile had 58% sensitivity (95% CI, 46–69%) and 93% negative predictive value (NPV) (95% CI, 90–95%), PlGF had 37% sensitivity (95% CI, 27–49%) and 90% NPV (95% CI, 87–93%); in combination, PlGF and EFW < 10(th) centile had 69% sensitivity (95% CI, 55–81%) and 93% NPV (95% CI, 89–96%). The equivalent receiver–operating characteristics (ROC) curve areas were 0.79 (95% CI, 0.74–0.84) for EFW < 10(th) centile, 0.70 (95% CI, 0.63–0.77) for low PlGF and 0.82 (95% CI, 0.77–0.86) in combination. CONCLUSIONS: For women presenting with reduced SFH, ultrasound parameters had modest test performance for predicting delivery of SGA < 3(rd) centile. PlGF performed no better than EFW < 10(th) centile in determining delivery of a SGA infant. © 2015 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the international society of ultrasound in obstetrics and gynecology. |
format | Online Article Text |
id | pubmed-4744762 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | John Wiley & Sons, Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-47447622016-02-18 Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height Griffin, M. Seed, P. T. Webster, L. Myers, J. MacKillop, L. Simpson, N. Anumba, D. Khalil, A. Denbow, M. Sau, A. Hinshaw, K. von Dadelszen, P. Benton, S. Girling, J. Redman, C. W. G. Chappell, L. C. Shennan, A. H. Ultrasound Obstet Gynecol Original Papers OBJECTIVES: To assess the diagnostic accuracy of placental growth factor (PlGF) and ultrasound parameters to predict delivery of a small‐for‐gestational‐age (SGA) infant in women presenting with reduced symphysis–fundus height (SFH). METHODS: This was a multicenter prospective observational study recruiting 601 women with a singleton pregnancy and reduced SFH between 24 and 37 weeks' gestation across 11 sites in the UK and Canada. Plasma PlGF concentration < 5(th) centile, estimated fetal weight (EFW) < 10(th) centile, umbilical artery Doppler pulsatility index > 95(th) centile and oligohydramnios (amniotic fluid index < 5 cm) were compared as predictors for a SGA infant < 3(rd) customized birth‐weight centile and adverse perinatal outcome. Test performance statistics were calculated for all parameters in isolation and in combination. RESULTS: Of the 601 women recruited, 592 were analyzed. For predicting delivery of SGA < 3(rd) centile (n = 78), EFW < 10(th) centile had 58% sensitivity (95% CI, 46–69%) and 93% negative predictive value (NPV) (95% CI, 90–95%), PlGF had 37% sensitivity (95% CI, 27–49%) and 90% NPV (95% CI, 87–93%); in combination, PlGF and EFW < 10(th) centile had 69% sensitivity (95% CI, 55–81%) and 93% NPV (95% CI, 89–96%). The equivalent receiver–operating characteristics (ROC) curve areas were 0.79 (95% CI, 0.74–0.84) for EFW < 10(th) centile, 0.70 (95% CI, 0.63–0.77) for low PlGF and 0.82 (95% CI, 0.77–0.86) in combination. CONCLUSIONS: For women presenting with reduced SFH, ultrasound parameters had modest test performance for predicting delivery of SGA < 3(rd) centile. PlGF performed no better than EFW < 10(th) centile in determining delivery of a SGA infant. © 2015 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the international society of ultrasound in obstetrics and gynecology. John Wiley & Sons, Ltd 2015-07-03 2015-08 /pmc/articles/PMC4744762/ /pubmed/25826778 http://dx.doi.org/10.1002/uog.14860 Text en © 2015 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the international society of ultrasound in obstetrics and gynecology. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs (http://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Papers Griffin, M. Seed, P. T. Webster, L. Myers, J. MacKillop, L. Simpson, N. Anumba, D. Khalil, A. Denbow, M. Sau, A. Hinshaw, K. von Dadelszen, P. Benton, S. Girling, J. Redman, C. W. G. Chappell, L. C. Shennan, A. H. Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height |
title | Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height |
title_full | Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height |
title_fullStr | Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height |
title_full_unstemmed | Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height |
title_short | Diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height |
title_sort | diagnostic accuracy of placental growth factor and ultrasound parameters to predict the small‐for‐gestational‐age infant in women presenting with reduced symphysis–fundus height |
topic | Original Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4744762/ https://www.ncbi.nlm.nih.gov/pubmed/25826778 http://dx.doi.org/10.1002/uog.14860 |
work_keys_str_mv | AT griffinm diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT seedpt diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT websterl diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT myersj diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT mackillopl diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT simpsonn diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT anumbad diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT khalila diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT denbowm diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT saua diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT hinshawk diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT vondadelszenp diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT bentons diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT girlingj diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT redmancwg diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT chappelllc diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight AT shennanah diagnosticaccuracyofplacentalgrowthfactorandultrasoundparameterstopredictthesmallforgestationalageinfantinwomenpresentingwithreducedsymphysisfundusheight |