Cargando…

Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand

In this study, we examined the diagnostic accuracy of the InBios Scrub Typhus Detect IgM enzyme-linked immunosorbent assay (ELISA) and determined the optimal diagnostic optical density (OD) cutoffs for screening and diagnostic applications based on prospectively collected, characterized samples from...

Descripción completa

Detalles Bibliográficos
Autores principales: Blacksell, Stuart D., Tanganuchitcharnchai, Ampai, Nawtaisong, Pruksa, Kantipong, Pacharee, Laongnualpanich, Achara, Day, Nicholas P. J., Paris, Daniel H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4744921/
https://www.ncbi.nlm.nih.gov/pubmed/26656118
http://dx.doi.org/10.1128/CVI.00553-15
_version_ 1782414547223576576
author Blacksell, Stuart D.
Tanganuchitcharnchai, Ampai
Nawtaisong, Pruksa
Kantipong, Pacharee
Laongnualpanich, Achara
Day, Nicholas P. J.
Paris, Daniel H.
author_facet Blacksell, Stuart D.
Tanganuchitcharnchai, Ampai
Nawtaisong, Pruksa
Kantipong, Pacharee
Laongnualpanich, Achara
Day, Nicholas P. J.
Paris, Daniel H.
author_sort Blacksell, Stuart D.
collection PubMed
description In this study, we examined the diagnostic accuracy of the InBios Scrub Typhus Detect IgM enzyme-linked immunosorbent assay (ELISA) and determined the optimal diagnostic optical density (OD) cutoffs for screening and diagnostic applications based on prospectively collected, characterized samples from undifferentiated febrile illness patients in northern Thailand. Direct comparisons with the serological gold standard, indirect immunofluorescence assay (IFA), revealed strong statistical correlation of ELISA OD values and IFA IgM titers. Determination of the optimal ELISA cutoff for seroepidemiology or screening purposes compared to the corresponding IFA reciprocal titer of 400 as previously described for Thailand was 0.60 OD, which corresponded to a sensitivity (Sn) of 84% and a specificity (Sp) of 98%. The diagnostic performance against the improved and more-stringent scrub typhus infection criteria (STIC), correcting for low false-positive IFA titers, resulted in an Sn of 93% and an Sp of 91% at an ELISA cutoff of 0.5 OD. This diagnostic ELISA cutoff corresponds to IFA reciprocal titers of 1,600 to 3,200, which greatly reduces the false-positive rates associated with low-positive IFA titers. These data are in congruence with the recently improved serodiagnostic positivity criteria using the Bayesian latent class modeling approach. In summary, the InBios Scrub Typhus Detect IgM ELISA is affordable and easy-to-use, with adequate diagnostic accuracy for screening and diagnostic purposes, and should be considered an improved alternative to the gold standard IFA for acute diagnosis. For broader application, regional cutoff validation and antigenic composition for consistent diagnostic accuracy should be considered.
format Online
Article
Text
id pubmed-4744921
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-47449212016-02-13 Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand Blacksell, Stuart D. Tanganuchitcharnchai, Ampai Nawtaisong, Pruksa Kantipong, Pacharee Laongnualpanich, Achara Day, Nicholas P. J. Paris, Daniel H. Clin Vaccine Immunol Diagnostic Laboratory Immunology In this study, we examined the diagnostic accuracy of the InBios Scrub Typhus Detect IgM enzyme-linked immunosorbent assay (ELISA) and determined the optimal diagnostic optical density (OD) cutoffs for screening and diagnostic applications based on prospectively collected, characterized samples from undifferentiated febrile illness patients in northern Thailand. Direct comparisons with the serological gold standard, indirect immunofluorescence assay (IFA), revealed strong statistical correlation of ELISA OD values and IFA IgM titers. Determination of the optimal ELISA cutoff for seroepidemiology or screening purposes compared to the corresponding IFA reciprocal titer of 400 as previously described for Thailand was 0.60 OD, which corresponded to a sensitivity (Sn) of 84% and a specificity (Sp) of 98%. The diagnostic performance against the improved and more-stringent scrub typhus infection criteria (STIC), correcting for low false-positive IFA titers, resulted in an Sn of 93% and an Sp of 91% at an ELISA cutoff of 0.5 OD. This diagnostic ELISA cutoff corresponds to IFA reciprocal titers of 1,600 to 3,200, which greatly reduces the false-positive rates associated with low-positive IFA titers. These data are in congruence with the recently improved serodiagnostic positivity criteria using the Bayesian latent class modeling approach. In summary, the InBios Scrub Typhus Detect IgM ELISA is affordable and easy-to-use, with adequate diagnostic accuracy for screening and diagnostic purposes, and should be considered an improved alternative to the gold standard IFA for acute diagnosis. For broader application, regional cutoff validation and antigenic composition for consistent diagnostic accuracy should be considered. American Society for Microbiology 2016-02-05 /pmc/articles/PMC4744921/ /pubmed/26656118 http://dx.doi.org/10.1128/CVI.00553-15 Text en Copyright © 2016 Blacksell et al. http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution 3.0 Unported license (http://creativecommons.org/licenses/by/3.0/) .
spellingShingle Diagnostic Laboratory Immunology
Blacksell, Stuart D.
Tanganuchitcharnchai, Ampai
Nawtaisong, Pruksa
Kantipong, Pacharee
Laongnualpanich, Achara
Day, Nicholas P. J.
Paris, Daniel H.
Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand
title Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand
title_full Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand
title_fullStr Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand
title_full_unstemmed Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand
title_short Diagnostic Accuracy of the InBios Scrub Typhus Detect Enzyme-Linked Immunoassay for the Detection of IgM Antibodies in Northern Thailand
title_sort diagnostic accuracy of the inbios scrub typhus detect enzyme-linked immunoassay for the detection of igm antibodies in northern thailand
topic Diagnostic Laboratory Immunology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4744921/
https://www.ncbi.nlm.nih.gov/pubmed/26656118
http://dx.doi.org/10.1128/CVI.00553-15
work_keys_str_mv AT blacksellstuartd diagnosticaccuracyoftheinbiosscrubtyphusdetectenzymelinkedimmunoassayforthedetectionofigmantibodiesinnorthernthailand
AT tanganuchitcharnchaiampai diagnosticaccuracyoftheinbiosscrubtyphusdetectenzymelinkedimmunoassayforthedetectionofigmantibodiesinnorthernthailand
AT nawtaisongpruksa diagnosticaccuracyoftheinbiosscrubtyphusdetectenzymelinkedimmunoassayforthedetectionofigmantibodiesinnorthernthailand
AT kantipongpacharee diagnosticaccuracyoftheinbiosscrubtyphusdetectenzymelinkedimmunoassayforthedetectionofigmantibodiesinnorthernthailand
AT laongnualpanichachara diagnosticaccuracyoftheinbiosscrubtyphusdetectenzymelinkedimmunoassayforthedetectionofigmantibodiesinnorthernthailand
AT daynicholaspj diagnosticaccuracyoftheinbiosscrubtyphusdetectenzymelinkedimmunoassayforthedetectionofigmantibodiesinnorthernthailand
AT parisdanielh diagnosticaccuracyoftheinbiosscrubtyphusdetectenzymelinkedimmunoassayforthedetectionofigmantibodiesinnorthernthailand