Cargando…

Long-term outcomes of endothelial keratoplasty in Chinese eyes at a University Hospital

BACKGROUND: Endothelial keratoplasty (EK) is used increasingly for the management of cases with endothelial dysfunction. Long-term outcomes of the surgery are not widely reported in the literature. We report our experience of EK in Chinese eyes at a University teaching hospital. METHODS: Retrospecti...

Descripción completa

Detalles Bibliográficos
Autores principales: Young, Alvin L, Kwok, Rachel PW, Jhanji, Vishal, Cheng, Lulu L, Rao, Srinivas K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4745171/
https://www.ncbi.nlm.nih.gov/pubmed/26858960
http://dx.doi.org/10.1186/s40662-014-0008-9
Descripción
Sumario:BACKGROUND: Endothelial keratoplasty (EK) is used increasingly for the management of cases with endothelial dysfunction. Long-term outcomes of the surgery are not widely reported in the literature. We report our experience of EK in Chinese eyes at a University teaching hospital. METHODS: Retrospective analysis was performed for all cases of EK performed between 2005 and 2009. Data analyzed included indication for surgery, associated surgical procedures, complications, best-corrected visual acuity (BCVA) and overall graft survival. RESULTS: Overall, 22 eyes of 21 patients underwent EK (13 males, 8 females, mean age 71.8 ± 11.3 years). Pseudophakic bullous keratopathy was the leading indication for surgery (n = 12) followed by Fuchs’ endothelial dystrophy (n = 4), or both (n = 3). Other indications for surgery included failed penetrating keratoplasty (n = 2) and endothelial decompensation due to multiple surgeries (n = 1). Triple procedure was performed in 5 (22.7%) cases. Complications were noted in the form of postoperative interface hemorrhage (n = 2, 9%) and graft dislocation (n = 1, 4.5%). The mean postoperative endothelial cell density was 1069 ± 585.8 cells/mm(2). The mean postoperative pachymetry was 675.8 ± 108.5 μm. The mean preoperative and postoperative intraocular pressure was 11.3 ± 3.2 and 13.9 ± 4.5 mmHg respectively. At the last follow-up (mean, 47.4 ± 13.7 months), BCVA was ≥20/70 in 9 (40.9%) cases. Causes of poor BCVA included primary graft failure (n = 4), graft decompensation (n = 4), advanced glaucoma (n = 2) and irreversible graft rejection (n = 2). Graft remained clear in 12 (54.5%) cases at the last follow-up. Average graft survival was 19.7 ± 17.7 months (median 17.5 months). CONCLUSIONS: Nearly half of the EK grafts in our study survived over a period of five years. Graft failure, glaucoma and graft rejection were the main causes of poor graft survival.