Cargando…
Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection
Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod). In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 ver...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4745427/ https://www.ncbi.nlm.nih.gov/pubmed/27019578 http://dx.doi.org/10.1155/2015/150649 |
_version_ | 1782414645308424192 |
---|---|
author | Çetin, Engin Özkaya, Mustafa Güler, Ümit Özgür Acaroğlu, Emre Demir, Teyfik |
author_facet | Çetin, Engin Özkaya, Mustafa Güler, Ümit Özgür Acaroğlu, Emre Demir, Teyfik |
author_sort | Çetin, Engin |
collection | PubMed |
description | Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod). In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P < 0.01). Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P < 0.005). Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant. |
format | Online Article Text |
id | pubmed-4745427 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-47454272016-03-27 Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection Çetin, Engin Özkaya, Mustafa Güler, Ümit Özgür Acaroğlu, Emre Demir, Teyfik Appl Bionics Biomech Research Article Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod). In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P < 0.01). Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P < 0.005). Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant. Hindawi Publishing Corporation 2015 2015-02-22 /pmc/articles/PMC4745427/ /pubmed/27019578 http://dx.doi.org/10.1155/2015/150649 Text en Copyright © 2015 Engin Çetin et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Çetin, Engin Özkaya, Mustafa Güler, Ümit Özgür Acaroğlu, Emre Demir, Teyfik Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection |
title | Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection |
title_full | Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection |
title_fullStr | Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection |
title_full_unstemmed | Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection |
title_short | Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection |
title_sort | evaluation of the effect of fixation angle between polyaxial pedicle screw head and rod on the failure of screw-rod connection |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4745427/ https://www.ncbi.nlm.nih.gov/pubmed/27019578 http://dx.doi.org/10.1155/2015/150649 |
work_keys_str_mv | AT cetinengin evaluationoftheeffectoffixationanglebetweenpolyaxialpediclescrewheadandrodonthefailureofscrewrodconnection AT ozkayamustafa evaluationoftheeffectoffixationanglebetweenpolyaxialpediclescrewheadandrodonthefailureofscrewrodconnection AT gulerumitozgur evaluationoftheeffectoffixationanglebetweenpolyaxialpediclescrewheadandrodonthefailureofscrewrodconnection AT acarogluemre evaluationoftheeffectoffixationanglebetweenpolyaxialpediclescrewheadandrodonthefailureofscrewrodconnection AT demirteyfik evaluationoftheeffectoffixationanglebetweenpolyaxialpediclescrewheadandrodonthefailureofscrewrodconnection |