Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging

INTRODUCTION: Positron emission tomography has been established as an important imaging modality in the management of patients, especially in oncology. The higher gamma radiation energy of positron-emitting isotopes poses an additional radiation safety problem. Those working with this modality may l...

Descripción completa

Detalles Bibliográficos
Autores principales: Verma, Shashwat, Kheruka, Subhash Chand, Maurya, Anil Kumar, Kumar, Narvesh, Gambhir, Sanjay, Kumari, Sarita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4746836/
https://www.ncbi.nlm.nih.gov/pubmed/26917890
http://dx.doi.org/10.4103/0972-3919.172348
_version_ 1782414874903576576
author Verma, Shashwat
Kheruka, Subhash Chand
Maurya, Anil Kumar
Kumar, Narvesh
Gambhir, Sanjay
Kumari, Sarita
author_facet Verma, Shashwat
Kheruka, Subhash Chand
Maurya, Anil Kumar
Kumar, Narvesh
Gambhir, Sanjay
Kumari, Sarita
author_sort Verma, Shashwat
collection PubMed
description INTRODUCTION: Positron emission tomography has been established as an important imaging modality in the management of patients, especially in oncology. The higher gamma radiation energy of positron-emitting isotopes poses an additional radiation safety problem. Those working with this modality may likely to receive higher whole body doses than those working only in conventional nuclear medicine. The radiation exposure to the personnel occurs in dispensing the dose, administration of activity, patient positioning, and while removing the intravenous (i.v.) cannula. The estimation of radiation dose to Nuclear Medicine Physician (NMP) involved during administration of activity to the patient and technical staff assisting in these procedures in a positron emission tomography/computed tomography (PET/CT) facility was carried out. MATERIALS AND METHODS: An i.v access was secured for the patient by putting the cannula and blood sugar was monitored. The activity was then dispensed and measured in the dose calibrator and administered to the patient by NMP. Personnel doses received by NMP and technical staff were measured using electronic pocket dosimeter. The radiation exposure levels at various working locations were assessed with the help of gamma survey meter. RESULTS AND DISCUSSION: The radiation level at working distance while administering the radioactivity was found to be 106–170 μSv/h with a mean value of 126.5 ± 14.88 μSv/h which was reduced to 4.2–14.2 μSv/h with a mean value of 7.16 ± 2.29 μSv/h with introduction of L-bench for administration of radioactivity. This shows a mean exposure level reduction of 94.45 ± 1.03%. The radiation level at working distance, while removing the i.v. cannula postscanning was found to be 25–70 μSv/h with a mean value of 37.4 ± 13.16 μSv/h which was reduced to 1.0–5.0 μSv/h with a mean value of 2.77 ± 1.3 μSv/h with introduction of L-bench for removal of i.v cannula. This shows a mean exposure level reduction of 92.85 ± 1.78%. CONCLUSION: This study shows that good radiation practices are very helpful in reducing the personnel radiation doses. Use of radiation protection devices such as L-bench reduces exposure significantly. PET/CT staff members must use their personnel monitors diligently and should do so in a consistent manner so that comparisons of their doses are meaningful from one monitoring period to the next.
format Online
Article
Text
id pubmed-4746836
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-47468362016-02-25 Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging Verma, Shashwat Kheruka, Subhash Chand Maurya, Anil Kumar Kumar, Narvesh Gambhir, Sanjay Kumari, Sarita Indian J Nucl Med Original Article INTRODUCTION: Positron emission tomography has been established as an important imaging modality in the management of patients, especially in oncology. The higher gamma radiation energy of positron-emitting isotopes poses an additional radiation safety problem. Those working with this modality may likely to receive higher whole body doses than those working only in conventional nuclear medicine. The radiation exposure to the personnel occurs in dispensing the dose, administration of activity, patient positioning, and while removing the intravenous (i.v.) cannula. The estimation of radiation dose to Nuclear Medicine Physician (NMP) involved during administration of activity to the patient and technical staff assisting in these procedures in a positron emission tomography/computed tomography (PET/CT) facility was carried out. MATERIALS AND METHODS: An i.v access was secured for the patient by putting the cannula and blood sugar was monitored. The activity was then dispensed and measured in the dose calibrator and administered to the patient by NMP. Personnel doses received by NMP and technical staff were measured using electronic pocket dosimeter. The radiation exposure levels at various working locations were assessed with the help of gamma survey meter. RESULTS AND DISCUSSION: The radiation level at working distance while administering the radioactivity was found to be 106–170 μSv/h with a mean value of 126.5 ± 14.88 μSv/h which was reduced to 4.2–14.2 μSv/h with a mean value of 7.16 ± 2.29 μSv/h with introduction of L-bench for administration of radioactivity. This shows a mean exposure level reduction of 94.45 ± 1.03%. The radiation level at working distance, while removing the i.v. cannula postscanning was found to be 25–70 μSv/h with a mean value of 37.4 ± 13.16 μSv/h which was reduced to 1.0–5.0 μSv/h with a mean value of 2.77 ± 1.3 μSv/h with introduction of L-bench for removal of i.v cannula. This shows a mean exposure level reduction of 92.85 ± 1.78%. CONCLUSION: This study shows that good radiation practices are very helpful in reducing the personnel radiation doses. Use of radiation protection devices such as L-bench reduces exposure significantly. PET/CT staff members must use their personnel monitors diligently and should do so in a consistent manner so that comparisons of their doses are meaningful from one monitoring period to the next. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4746836/ /pubmed/26917890 http://dx.doi.org/10.4103/0972-3919.172348 Text en Copyright: © Indian Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Verma, Shashwat
Kheruka, Subhash Chand
Maurya, Anil Kumar
Kumar, Narvesh
Gambhir, Sanjay
Kumari, Sarita
Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging
title Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging
title_full Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging
title_fullStr Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging
title_full_unstemmed Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging
title_short Benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)F-fluorodeoxyglucose positron emission tomography/computed tomography imaging
title_sort benefits of adopting good radiation practices in reducing the whole body radiation dose to the nuclear medicine personnel during (18)f-fluorodeoxyglucose positron emission tomography/computed tomography imaging
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4746836/
https://www.ncbi.nlm.nih.gov/pubmed/26917890
http://dx.doi.org/10.4103/0972-3919.172348
work_keys_str_mv AT vermashashwat benefitsofadoptinggoodradiationpracticesinreducingthewholebodyradiationdosetothenuclearmedicinepersonnelduring18ffluorodeoxyglucosepositronemissiontomographycomputedtomographyimaging
AT kherukasubhashchand benefitsofadoptinggoodradiationpracticesinreducingthewholebodyradiationdosetothenuclearmedicinepersonnelduring18ffluorodeoxyglucosepositronemissiontomographycomputedtomographyimaging
AT mauryaanilkumar benefitsofadoptinggoodradiationpracticesinreducingthewholebodyradiationdosetothenuclearmedicinepersonnelduring18ffluorodeoxyglucosepositronemissiontomographycomputedtomographyimaging
AT kumarnarvesh benefitsofadoptinggoodradiationpracticesinreducingthewholebodyradiationdosetothenuclearmedicinepersonnelduring18ffluorodeoxyglucosepositronemissiontomographycomputedtomographyimaging
AT gambhirsanjay benefitsofadoptinggoodradiationpracticesinreducingthewholebodyradiationdosetothenuclearmedicinepersonnelduring18ffluorodeoxyglucosepositronemissiontomographycomputedtomographyimaging
AT kumarisarita benefitsofadoptinggoodradiationpracticesinreducingthewholebodyradiationdosetothenuclearmedicinepersonnelduring18ffluorodeoxyglucosepositronemissiontomographycomputedtomographyimaging