Cargando…
Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up?
PURPOSE: To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics. METHODS: Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4747473/ https://www.ncbi.nlm.nih.gov/pubmed/26859665 http://dx.doi.org/10.1371/journal.pone.0148853 |
_version_ | 1782414983807631360 |
---|---|
author | Kim, Hyungjin Park, Chang Min Song, Yong Sub Sunwoo, Leonard Choi, Ye Ra Kim, Jung Im Kim, Jae Hyun Bae, Jae Seok Lee, Jong Hyuk Goo, Jin Mo |
author_facet | Kim, Hyungjin Park, Chang Min Song, Yong Sub Sunwoo, Leonard Choi, Ye Ra Kim, Jung Im Kim, Jae Hyun Bae, Jae Seok Lee, Jong Hyuk Goo, Jin Mo |
author_sort | Kim, Hyungjin |
collection | PubMed |
description | PURPOSE: To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics. METHODS: Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons. RESULTS: Measurement variability for the longest and average diameter of SSNs was ±1.3 mm (±13.0%) and ±1.3 mm (±14.4%) in situation 1, and ±2.2 mm (±21.0%) and ±2.1 mm (±21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was ±1.2 mm (±27.1%) and ±0.8 mm (±24.0%) in situation 1, and ±3.7 mm (±61.0%) and ±1.5 mm (±47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001). CONCLUSIONS: A cutoff of ±2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs’ change when readers of initial and follow-up CT were different. |
format | Online Article Text |
id | pubmed-4747473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47474732016-02-22 Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up? Kim, Hyungjin Park, Chang Min Song, Yong Sub Sunwoo, Leonard Choi, Ye Ra Kim, Jung Im Kim, Jae Hyun Bae, Jae Seok Lee, Jong Hyuk Goo, Jin Mo PLoS One Research Article PURPOSE: To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics. METHODS: Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons. RESULTS: Measurement variability for the longest and average diameter of SSNs was ±1.3 mm (±13.0%) and ±1.3 mm (±14.4%) in situation 1, and ±2.2 mm (±21.0%) and ±2.1 mm (±21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was ±1.2 mm (±27.1%) and ±0.8 mm (±24.0%) in situation 1, and ±3.7 mm (±61.0%) and ±1.5 mm (±47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001). CONCLUSIONS: A cutoff of ±2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs’ change when readers of initial and follow-up CT were different. Public Library of Science 2016-02-09 /pmc/articles/PMC4747473/ /pubmed/26859665 http://dx.doi.org/10.1371/journal.pone.0148853 Text en © 2016 Kim et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kim, Hyungjin Park, Chang Min Song, Yong Sub Sunwoo, Leonard Choi, Ye Ra Kim, Jung Im Kim, Jae Hyun Bae, Jae Seok Lee, Jong Hyuk Goo, Jin Mo Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up? |
title | Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up? |
title_full | Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up? |
title_fullStr | Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up? |
title_full_unstemmed | Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up? |
title_short | Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up? |
title_sort | measurement variability of persistent pulmonary subsolid nodules on same-day repeat ct: what is the threshold to determine true nodule growth during follow-up? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4747473/ https://www.ncbi.nlm.nih.gov/pubmed/26859665 http://dx.doi.org/10.1371/journal.pone.0148853 |
work_keys_str_mv | AT kimhyungjin measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT parkchangmin measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT songyongsub measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT sunwooleonard measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT choiyera measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT kimjungim measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT kimjaehyun measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT baejaeseok measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT leejonghyuk measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup AT goojinmo measurementvariabilityofpersistentpulmonarysubsolidnodulesonsamedayrepeatctwhatisthethresholdtodeterminetruenodulegrowthduringfollowup |