Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training
AIM: To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation. METHODS: A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics particip...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4747546/ https://www.ncbi.nlm.nih.gov/pubmed/26859896 http://dx.doi.org/10.1371/journal.pone.0148475 |
_version_ | 1782415000423366656 |
---|---|
author | do Prado, Cristiane Guinsburg, Ruth de Almeida, Maria Fernanda Branco Mascaretti, Renata Suman Vale, Luciana Assis Haddad, Luciana Branco Rebello, Celso Moura |
author_facet | do Prado, Cristiane Guinsburg, Ruth de Almeida, Maria Fernanda Branco Mascaretti, Renata Suman Vale, Luciana Assis Haddad, Luciana Branco Rebello, Celso Moura |
author_sort | do Prado, Cristiane |
collection | PubMed |
description | AIM: To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation. METHODS: A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped resuscitator (T-piece), followed by an analysis of the effectiveness of the equipment according to the participants’ education and training. RESULTS: A difference between equipment types was observed for the tidal volume, with a median (interquartile range) of 28.5 mL (12.6) for the self-inflating bag and 20.1 mL (8.4) for the T-piece in the instructor group and 31.6 mL (14) for the self-inflating bag and 22.3 mL (8.8) for the T-piece in the non-instructor group. Higher inspiratory time values were observed with the T-piece in both groups of professionals, with no significant difference between them. The operator’s ability to maintain the target pressure over the 10 seconds of sustained lung inflation was evaluated using the area under the pressure-time curve and was 1.7-fold higher with the use of the T-piece. Inspiratory pressure and mean airway pressure applied during sustained lung inflation were greater with the self-inflating bag, as evaluated between the beginning and the end of the procedure. CONCLUSION: The T-piece resulted in lower tidal volume and higher inspiratory time values, irrespective of the operator’s experience, and increased the ease of performing the sustained lung inflation maneuver, as demonstrated by the maintenance of target pressure for the desired period and a higher mean airway pressure than that obtained using the self-inflating bag. |
format | Online Article Text |
id | pubmed-4747546 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-47475462016-02-22 Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training do Prado, Cristiane Guinsburg, Ruth de Almeida, Maria Fernanda Branco Mascaretti, Renata Suman Vale, Luciana Assis Haddad, Luciana Branco Rebello, Celso Moura PLoS One Research Article AIM: To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation. METHODS: A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped resuscitator (T-piece), followed by an analysis of the effectiveness of the equipment according to the participants’ education and training. RESULTS: A difference between equipment types was observed for the tidal volume, with a median (interquartile range) of 28.5 mL (12.6) for the self-inflating bag and 20.1 mL (8.4) for the T-piece in the instructor group and 31.6 mL (14) for the self-inflating bag and 22.3 mL (8.8) for the T-piece in the non-instructor group. Higher inspiratory time values were observed with the T-piece in both groups of professionals, with no significant difference between them. The operator’s ability to maintain the target pressure over the 10 seconds of sustained lung inflation was evaluated using the area under the pressure-time curve and was 1.7-fold higher with the use of the T-piece. Inspiratory pressure and mean airway pressure applied during sustained lung inflation were greater with the self-inflating bag, as evaluated between the beginning and the end of the procedure. CONCLUSION: The T-piece resulted in lower tidal volume and higher inspiratory time values, irrespective of the operator’s experience, and increased the ease of performing the sustained lung inflation maneuver, as demonstrated by the maintenance of target pressure for the desired period and a higher mean airway pressure than that obtained using the self-inflating bag. Public Library of Science 2016-02-09 /pmc/articles/PMC4747546/ /pubmed/26859896 http://dx.doi.org/10.1371/journal.pone.0148475 Text en © 2016 do Prado et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article do Prado, Cristiane Guinsburg, Ruth de Almeida, Maria Fernanda Branco Mascaretti, Renata Suman Vale, Luciana Assis Haddad, Luciana Branco Rebello, Celso Moura Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training |
title | Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training |
title_full | Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training |
title_fullStr | Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training |
title_full_unstemmed | Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training |
title_short | Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training |
title_sort | manual ventilation and sustained lung inflation in an experimental model: influence of equipment type and operator’s training |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4747546/ https://www.ncbi.nlm.nih.gov/pubmed/26859896 http://dx.doi.org/10.1371/journal.pone.0148475 |
work_keys_str_mv | AT dopradocristiane manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining AT guinsburgruth manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining AT dealmeidamariafernandabranco manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining AT mascarettirenatasuman manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining AT valelucianaassis manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining AT haddadlucianabranco manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining AT rebellocelsomoura manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining |