Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training

AIM: To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation. METHODS: A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics particip...

Descripción completa

Detalles Bibliográficos
Autores principales: do Prado, Cristiane, Guinsburg, Ruth, de Almeida, Maria Fernanda Branco, Mascaretti, Renata Suman, Vale, Luciana Assis, Haddad, Luciana Branco, Rebello, Celso Moura
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4747546/
https://www.ncbi.nlm.nih.gov/pubmed/26859896
http://dx.doi.org/10.1371/journal.pone.0148475
_version_ 1782415000423366656
author do Prado, Cristiane
Guinsburg, Ruth
de Almeida, Maria Fernanda Branco
Mascaretti, Renata Suman
Vale, Luciana Assis
Haddad, Luciana Branco
Rebello, Celso Moura
author_facet do Prado, Cristiane
Guinsburg, Ruth
de Almeida, Maria Fernanda Branco
Mascaretti, Renata Suman
Vale, Luciana Assis
Haddad, Luciana Branco
Rebello, Celso Moura
author_sort do Prado, Cristiane
collection PubMed
description AIM: To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation. METHODS: A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped resuscitator (T-piece), followed by an analysis of the effectiveness of the equipment according to the participants’ education and training. RESULTS: A difference between equipment types was observed for the tidal volume, with a median (interquartile range) of 28.5 mL (12.6) for the self-inflating bag and 20.1 mL (8.4) for the T-piece in the instructor group and 31.6 mL (14) for the self-inflating bag and 22.3 mL (8.8) for the T-piece in the non-instructor group. Higher inspiratory time values were observed with the T-piece in both groups of professionals, with no significant difference between them. The operator’s ability to maintain the target pressure over the 10 seconds of sustained lung inflation was evaluated using the area under the pressure-time curve and was 1.7-fold higher with the use of the T-piece. Inspiratory pressure and mean airway pressure applied during sustained lung inflation were greater with the self-inflating bag, as evaluated between the beginning and the end of the procedure. CONCLUSION: The T-piece resulted in lower tidal volume and higher inspiratory time values, irrespective of the operator’s experience, and increased the ease of performing the sustained lung inflation maneuver, as demonstrated by the maintenance of target pressure for the desired period and a higher mean airway pressure than that obtained using the self-inflating bag.
format Online
Article
Text
id pubmed-4747546
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47475462016-02-22 Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training do Prado, Cristiane Guinsburg, Ruth de Almeida, Maria Fernanda Branco Mascaretti, Renata Suman Vale, Luciana Assis Haddad, Luciana Branco Rebello, Celso Moura PLoS One Research Article AIM: To compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation. METHODS: A total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped resuscitator (T-piece), followed by an analysis of the effectiveness of the equipment according to the participants’ education and training. RESULTS: A difference between equipment types was observed for the tidal volume, with a median (interquartile range) of 28.5 mL (12.6) for the self-inflating bag and 20.1 mL (8.4) for the T-piece in the instructor group and 31.6 mL (14) for the self-inflating bag and 22.3 mL (8.8) for the T-piece in the non-instructor group. Higher inspiratory time values were observed with the T-piece in both groups of professionals, with no significant difference between them. The operator’s ability to maintain the target pressure over the 10 seconds of sustained lung inflation was evaluated using the area under the pressure-time curve and was 1.7-fold higher with the use of the T-piece. Inspiratory pressure and mean airway pressure applied during sustained lung inflation were greater with the self-inflating bag, as evaluated between the beginning and the end of the procedure. CONCLUSION: The T-piece resulted in lower tidal volume and higher inspiratory time values, irrespective of the operator’s experience, and increased the ease of performing the sustained lung inflation maneuver, as demonstrated by the maintenance of target pressure for the desired period and a higher mean airway pressure than that obtained using the self-inflating bag. Public Library of Science 2016-02-09 /pmc/articles/PMC4747546/ /pubmed/26859896 http://dx.doi.org/10.1371/journal.pone.0148475 Text en © 2016 do Prado et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
do Prado, Cristiane
Guinsburg, Ruth
de Almeida, Maria Fernanda Branco
Mascaretti, Renata Suman
Vale, Luciana Assis
Haddad, Luciana Branco
Rebello, Celso Moura
Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training
title Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training
title_full Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training
title_fullStr Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training
title_full_unstemmed Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training
title_short Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training
title_sort manual ventilation and sustained lung inflation in an experimental model: influence of equipment type and operator’s training
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4747546/
https://www.ncbi.nlm.nih.gov/pubmed/26859896
http://dx.doi.org/10.1371/journal.pone.0148475
work_keys_str_mv AT dopradocristiane manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining
AT guinsburgruth manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining
AT dealmeidamariafernandabranco manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining
AT mascarettirenatasuman manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining
AT valelucianaassis manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining
AT haddadlucianabranco manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining
AT rebellocelsomoura manualventilationandsustainedlunginflationinanexperimentalmodelinfluenceofequipmenttypeandoperatorstraining