Cargando…
Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting
BACKGROUND: Haemorrhagic shock is a major cause of death in the acute care setting. Since 2009, our emergency department has used intra-aortic balloon occlusion (IABO) catheters for resuscitative endovascular balloon occlusion of the aorta (REBOA). METHODS: REBOA procedures were performed by one or...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4748599/ https://www.ncbi.nlm.nih.gov/pubmed/26861070 http://dx.doi.org/10.1186/s13049-016-0205-8 |
_version_ | 1782415149506756608 |
---|---|
author | Tsurukiri, Junya Akamine, Itsurou Sato, Takao Sakurai, Masatsugu Okumura, Eitaro Moriya, Mariko Yamanaka, Hiroshi Ohta, Shoichi |
author_facet | Tsurukiri, Junya Akamine, Itsurou Sato, Takao Sakurai, Masatsugu Okumura, Eitaro Moriya, Mariko Yamanaka, Hiroshi Ohta, Shoichi |
author_sort | Tsurukiri, Junya |
collection | PubMed |
description | BACKGROUND: Haemorrhagic shock is a major cause of death in the acute care setting. Since 2009, our emergency department has used intra-aortic balloon occlusion (IABO) catheters for resuscitative endovascular balloon occlusion of the aorta (REBOA). METHODS: REBOA procedures were performed by one or two trained acute care physicians in the emergency room (ER) and intensive care unit (ICU). IABO catheters were positioned using ultrasonography. Collected data included clinical characteristics, haemorrhagic severity, blood cultures, metabolic values, blood transfusions, REBOA-related complications and mortality. RESULTS: Subjects comprised 25 patients (trauma, n = 16; non-trauma, n = 9) with a median age of 69 years and a median shock index of 1.4. REBOA was achieved in 22 patients, but failed in three elderly trauma patients. Systolic blood pressure significantly increased after REBOA (107 vs. 71 mmHg, p < 0.01). Five trauma patients (20 %) died in ER, and mortality rates within 24 h and 60 days were 20 % and 12 %, respectively. No REBOA-related complications were encountered. The total occlusion time of REBOA was significantly lesser in survivors than that in non-survivors (52 vs. 97 min, p < 0.01). Significantly positive correlations were found between total occlusion time of REBOA and shock index (Spearman’s r = 0.6) and lactate concentration (Spearman’s r = 0.7) in survivors. CONCLUSION: REBOA can be performed in ER and ICU with a high degree of technical success. Furthermore, correlations between occlusion time and initial high lactate levels and shock index may be important because prolonged occlusion is associated with a poorer outcome. |
format | Online Article Text |
id | pubmed-4748599 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-47485992016-02-11 Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting Tsurukiri, Junya Akamine, Itsurou Sato, Takao Sakurai, Masatsugu Okumura, Eitaro Moriya, Mariko Yamanaka, Hiroshi Ohta, Shoichi Scand J Trauma Resusc Emerg Med Original Research BACKGROUND: Haemorrhagic shock is a major cause of death in the acute care setting. Since 2009, our emergency department has used intra-aortic balloon occlusion (IABO) catheters for resuscitative endovascular balloon occlusion of the aorta (REBOA). METHODS: REBOA procedures were performed by one or two trained acute care physicians in the emergency room (ER) and intensive care unit (ICU). IABO catheters were positioned using ultrasonography. Collected data included clinical characteristics, haemorrhagic severity, blood cultures, metabolic values, blood transfusions, REBOA-related complications and mortality. RESULTS: Subjects comprised 25 patients (trauma, n = 16; non-trauma, n = 9) with a median age of 69 years and a median shock index of 1.4. REBOA was achieved in 22 patients, but failed in three elderly trauma patients. Systolic blood pressure significantly increased after REBOA (107 vs. 71 mmHg, p < 0.01). Five trauma patients (20 %) died in ER, and mortality rates within 24 h and 60 days were 20 % and 12 %, respectively. No REBOA-related complications were encountered. The total occlusion time of REBOA was significantly lesser in survivors than that in non-survivors (52 vs. 97 min, p < 0.01). Significantly positive correlations were found between total occlusion time of REBOA and shock index (Spearman’s r = 0.6) and lactate concentration (Spearman’s r = 0.7) in survivors. CONCLUSION: REBOA can be performed in ER and ICU with a high degree of technical success. Furthermore, correlations between occlusion time and initial high lactate levels and shock index may be important because prolonged occlusion is associated with a poorer outcome. BioMed Central 2016-02-09 /pmc/articles/PMC4748599/ /pubmed/26861070 http://dx.doi.org/10.1186/s13049-016-0205-8 Text en © Tsurukiri et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Original Research Tsurukiri, Junya Akamine, Itsurou Sato, Takao Sakurai, Masatsugu Okumura, Eitaro Moriya, Mariko Yamanaka, Hiroshi Ohta, Shoichi Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting |
title | Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting |
title_full | Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting |
title_fullStr | Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting |
title_full_unstemmed | Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting |
title_short | Resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting |
title_sort | resuscitative endovascular balloon occlusion of the aorta for uncontrolled haemorrahgic shock as an adjunct to haemostatic procedures in the acute care setting |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4748599/ https://www.ncbi.nlm.nih.gov/pubmed/26861070 http://dx.doi.org/10.1186/s13049-016-0205-8 |
work_keys_str_mv | AT tsurukirijunya resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting AT akamineitsurou resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting AT satotakao resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting AT sakuraimasatsugu resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting AT okumuraeitaro resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting AT moriyamariko resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting AT yamanakahiroshi resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting AT ohtashoichi resuscitativeendovascularballoonocclusionoftheaortaforuncontrolledhaemorrahgicshockasanadjuncttohaemostaticproceduresintheacutecaresetting |