Cargando…

A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers

BACKGROUND: Hypoxia-based cell culture experiments are routine and essential components of in vitro cancer research. Most laboratories use low-cost portable modular chambers to achieve hypoxic conditions for cell cultures, where the sealed chambers are purged with a gas mixture of preset O(2) concen...

Descripción completa

Detalles Bibliográficos
Autores principales: Mathupala, Saroj P., Kiousis, Sam, Szerlip, Nicholas J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749204/
https://www.ncbi.nlm.nih.gov/pubmed/26862760
http://dx.doi.org/10.1371/journal.pone.0148923
_version_ 1782415240582922240
author Mathupala, Saroj P.
Kiousis, Sam
Szerlip, Nicholas J.
author_facet Mathupala, Saroj P.
Kiousis, Sam
Szerlip, Nicholas J.
author_sort Mathupala, Saroj P.
collection PubMed
description BACKGROUND: Hypoxia-based cell culture experiments are routine and essential components of in vitro cancer research. Most laboratories use low-cost portable modular chambers to achieve hypoxic conditions for cell cultures, where the sealed chambers are purged with a gas mixture of preset O(2) concentration. Studies are conducted under the assumption that hypoxia remains unaltered throughout the 48 to 72 hour duration of such experiments. Since these chambers lack any sensor or detection system to monitor gas-phase O(2), the cell-based data tend to be non-uniform due to the ad hoc nature of the experimental setup. METHODOLOGY: With the availability of low-cost open-source microcontroller-based electronic project kits, it is now possible for researchers to program these with easy-to-use software, link them to sensors, and place them in basic scientific apparatus to monitor and record experimental parameters. We report here the design and construction of a small-footprint kit for continuous measurement and recording of O(2) concentration in modular hypoxia chambers. The low-cost assembly (US$135) consists of an Arduino-based microcontroller, data-logging freeware, and a factory pre-calibrated miniature O(2) sensor. A small, intuitive software program was written by the authors to control the data input and output. The basic nature of the kit will enable any student in biology with minimal experience in hobby-electronics to assemble the system and edit the program parameters to suit individual experimental conditions. RESULTS/CONCLUSIONS: We show the kit’s utility and stability of data output via a series of hypoxia experiments. The studies also demonstrated the critical need to monitor and adjust gas-phase O(2) concentration during hypoxia-based experiments to prevent experimental errors or failure due to partial loss of hypoxia. Thus, incorporating the sensor-microcontroller module to a portable hypoxia chamber provides a researcher a capability that was previously available only to labs with access to sophisticated (and expensive) cell culture incubators.
format Online
Article
Text
id pubmed-4749204
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-47492042016-02-26 A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers Mathupala, Saroj P. Kiousis, Sam Szerlip, Nicholas J. PLoS One Research Article BACKGROUND: Hypoxia-based cell culture experiments are routine and essential components of in vitro cancer research. Most laboratories use low-cost portable modular chambers to achieve hypoxic conditions for cell cultures, where the sealed chambers are purged with a gas mixture of preset O(2) concentration. Studies are conducted under the assumption that hypoxia remains unaltered throughout the 48 to 72 hour duration of such experiments. Since these chambers lack any sensor or detection system to monitor gas-phase O(2), the cell-based data tend to be non-uniform due to the ad hoc nature of the experimental setup. METHODOLOGY: With the availability of low-cost open-source microcontroller-based electronic project kits, it is now possible for researchers to program these with easy-to-use software, link them to sensors, and place them in basic scientific apparatus to monitor and record experimental parameters. We report here the design and construction of a small-footprint kit for continuous measurement and recording of O(2) concentration in modular hypoxia chambers. The low-cost assembly (US$135) consists of an Arduino-based microcontroller, data-logging freeware, and a factory pre-calibrated miniature O(2) sensor. A small, intuitive software program was written by the authors to control the data input and output. The basic nature of the kit will enable any student in biology with minimal experience in hobby-electronics to assemble the system and edit the program parameters to suit individual experimental conditions. RESULTS/CONCLUSIONS: We show the kit’s utility and stability of data output via a series of hypoxia experiments. The studies also demonstrated the critical need to monitor and adjust gas-phase O(2) concentration during hypoxia-based experiments to prevent experimental errors or failure due to partial loss of hypoxia. Thus, incorporating the sensor-microcontroller module to a portable hypoxia chamber provides a researcher a capability that was previously available only to labs with access to sophisticated (and expensive) cell culture incubators. Public Library of Science 2016-02-10 /pmc/articles/PMC4749204/ /pubmed/26862760 http://dx.doi.org/10.1371/journal.pone.0148923 Text en © 2016 Mathupala et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mathupala, Saroj P.
Kiousis, Sam
Szerlip, Nicholas J.
A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers
title A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers
title_full A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers
title_fullStr A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers
title_full_unstemmed A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers
title_short A Lab Assembled Microcontroller-Based Sensor Module for Continuous Oxygen Measurement in Portable Hypoxia Chambers
title_sort lab assembled microcontroller-based sensor module for continuous oxygen measurement in portable hypoxia chambers
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749204/
https://www.ncbi.nlm.nih.gov/pubmed/26862760
http://dx.doi.org/10.1371/journal.pone.0148923
work_keys_str_mv AT mathupalasarojp alabassembledmicrocontrollerbasedsensormoduleforcontinuousoxygenmeasurementinportablehypoxiachambers
AT kiousissam alabassembledmicrocontrollerbasedsensormoduleforcontinuousoxygenmeasurementinportablehypoxiachambers
AT szerlipnicholasj alabassembledmicrocontrollerbasedsensormoduleforcontinuousoxygenmeasurementinportablehypoxiachambers
AT mathupalasarojp labassembledmicrocontrollerbasedsensormoduleforcontinuousoxygenmeasurementinportablehypoxiachambers
AT kiousissam labassembledmicrocontrollerbasedsensormoduleforcontinuousoxygenmeasurementinportablehypoxiachambers
AT szerlipnicholasj labassembledmicrocontrollerbasedsensormoduleforcontinuousoxygenmeasurementinportablehypoxiachambers