Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method

OBJECTIVES: Cleaning and shaping of the root canal system is an important step in endodontic therapy. New instruments incorporate new preparation techniques that can improve the efficacy of cleaning and shaping. The aim of this study was to compare the efficacy of Mtwo and RaCe rotary file systems i...

Descripción completa

Detalles Bibliográficos
Autores principales: Aminsobhani, Mohsen, Razmi, Hasan, Nozari, Solmaz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749412/
https://www.ncbi.nlm.nih.gov/pubmed/26877736
_version_ 1782415276779765760
author Aminsobhani, Mohsen
Razmi, Hasan
Nozari, Solmaz
author_facet Aminsobhani, Mohsen
Razmi, Hasan
Nozari, Solmaz
author_sort Aminsobhani, Mohsen
collection PubMed
description OBJECTIVES: Cleaning and shaping of the root canal system is an important step in endodontic therapy. New instruments incorporate new preparation techniques that can improve the efficacy of cleaning and shaping. The aim of this study was to compare the efficacy of Mtwo and RaCe rotary file systems in straightening the canal curvature using only one file or the conventional method. MATERIALS AND METHODS: Sixty mesial roots of extracted human mandibular molars were prepared by RaCe and Mtwo nickel-titanium (NiTi) rotary files using the conventional and only one rotary file methods. The working length was 18 mm and the curvatures of the root canals were between 15–45°. By superimposing x-ray images before and after the instrumentation, deviation of the canals was assessed using Adobe Photoshop CS3 software. Preparation time was recorded. Data were analyzed using three-way ANOVA and Tukey’s post hoc test. RESULTS: There were no significant differences between RaCe and Mtwo or between the two root canal preparation methods in root canal deviation in buccolingual and mesiodistal radiographs (P>0.05). Changes of root canal curvature in >35° subgroups were significantly more than in other subgroups with smaller canal curvatures. Preparation time was shorter in one file only technique. CONCLUSION: According to the results, the two rotary systems and the two root canal preparation methods had equal efficacy in straightening the canals; but the preparation time was shorter in one file only group.
format Online
Article
Text
id pubmed-4749412
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-47494122016-02-12 Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method Aminsobhani, Mohsen Razmi, Hasan Nozari, Solmaz J Dent (Tehran) Original Article OBJECTIVES: Cleaning and shaping of the root canal system is an important step in endodontic therapy. New instruments incorporate new preparation techniques that can improve the efficacy of cleaning and shaping. The aim of this study was to compare the efficacy of Mtwo and RaCe rotary file systems in straightening the canal curvature using only one file or the conventional method. MATERIALS AND METHODS: Sixty mesial roots of extracted human mandibular molars were prepared by RaCe and Mtwo nickel-titanium (NiTi) rotary files using the conventional and only one rotary file methods. The working length was 18 mm and the curvatures of the root canals were between 15–45°. By superimposing x-ray images before and after the instrumentation, deviation of the canals was assessed using Adobe Photoshop CS3 software. Preparation time was recorded. Data were analyzed using three-way ANOVA and Tukey’s post hoc test. RESULTS: There were no significant differences between RaCe and Mtwo or between the two root canal preparation methods in root canal deviation in buccolingual and mesiodistal radiographs (P>0.05). Changes of root canal curvature in >35° subgroups were significantly more than in other subgroups with smaller canal curvatures. Preparation time was shorter in one file only technique. CONCLUSION: According to the results, the two rotary systems and the two root canal preparation methods had equal efficacy in straightening the canals; but the preparation time was shorter in one file only group. Tehran University of Medical Sciences 2015-07 /pmc/articles/PMC4749412/ /pubmed/26877736 Text en Copyright© Dental Research Center, Tehran University of Medical Sciences This work is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Aminsobhani, Mohsen
Razmi, Hasan
Nozari, Solmaz
Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method
title Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method
title_full Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method
title_fullStr Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method
title_full_unstemmed Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method
title_short Ex Vivo Comparison of Mtwo and RaCe Rotary File Systems in Root Canal Deviation: One File Only versus the Conventional Method
title_sort ex vivo comparison of mtwo and race rotary file systems in root canal deviation: one file only versus the conventional method
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749412/
https://www.ncbi.nlm.nih.gov/pubmed/26877736
work_keys_str_mv AT aminsobhanimohsen exvivocomparisonofmtwoandracerotaryfilesystemsinrootcanaldeviationonefileonlyversustheconventionalmethod
AT razmihasan exvivocomparisonofmtwoandracerotaryfilesystemsinrootcanaldeviationonefileonlyversustheconventionalmethod
AT nozarisolmaz exvivocomparisonofmtwoandracerotaryfilesystemsinrootcanaldeviationonefileonlyversustheconventionalmethod