Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements
In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP) measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS) proteins. NCS proteins exhibit calcium-dependent mobility shift i...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749937/ https://www.ncbi.nlm.nih.gov/pubmed/26937454 http://dx.doi.org/10.1016/j.dib.2016.01.030 |
_version_ | 1782415343799500800 |
---|---|
author | Viviano, Jeffrey Wu, Hao Krishnan, Anuradha Ramanujachary, Kandalam Venkataraman, Venkat |
author_facet | Viviano, Jeffrey Wu, Hao Krishnan, Anuradha Ramanujachary, Kandalam Venkataraman, Venkat |
author_sort | Viviano, Jeffrey |
collection | PubMed |
description | In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP) measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS) proteins. NCS proteins exhibit calcium-dependent mobility shift in native gels. The sensitivity of this shift to calcium necessitated a precise determination of calcium concentrations in all reagents used. We determined the calcium concentrations in different components used along with the samples in the native gel experiments. These were: 20 mM Tris pH 7.5, loading dye and running buffer, with distilled water as reference. Calcium determinations were through ICP measurements. It was found that the running buffer contained calcium (244 nM) over the blank. |
format | Online Article Text |
id | pubmed-4749937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-47499372016-03-02 Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements Viviano, Jeffrey Wu, Hao Krishnan, Anuradha Ramanujachary, Kandalam Venkataraman, Venkat Data Brief Data Article In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP) measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS) proteins. NCS proteins exhibit calcium-dependent mobility shift in native gels. The sensitivity of this shift to calcium necessitated a precise determination of calcium concentrations in all reagents used. We determined the calcium concentrations in different components used along with the samples in the native gel experiments. These were: 20 mM Tris pH 7.5, loading dye and running buffer, with distilled water as reference. Calcium determinations were through ICP measurements. It was found that the running buffer contained calcium (244 nM) over the blank. Elsevier 2016-01-29 /pmc/articles/PMC4749937/ /pubmed/26937454 http://dx.doi.org/10.1016/j.dib.2016.01.030 Text en © 2016 Published by Elsevier Inc. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Data Article Viviano, Jeffrey Wu, Hao Krishnan, Anuradha Ramanujachary, Kandalam Venkataraman, Venkat Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements |
title | Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements |
title_full | Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements |
title_fullStr | Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements |
title_full_unstemmed | Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements |
title_short | Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements |
title_sort | data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements |
topic | Data Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749937/ https://www.ncbi.nlm.nih.gov/pubmed/26937454 http://dx.doi.org/10.1016/j.dib.2016.01.030 |
work_keys_str_mv | AT vivianojeffrey dataonfinalcalciumconcentrationinnativegelreagentsdeterminedaccuratelythroughinductivelycoupledplasmameasurements AT wuhao dataonfinalcalciumconcentrationinnativegelreagentsdeterminedaccuratelythroughinductivelycoupledplasmameasurements AT krishnananuradha dataonfinalcalciumconcentrationinnativegelreagentsdeterminedaccuratelythroughinductivelycoupledplasmameasurements AT ramanujacharykandalam dataonfinalcalciumconcentrationinnativegelreagentsdeterminedaccuratelythroughinductivelycoupledplasmameasurements AT venkataramanvenkat dataonfinalcalciumconcentrationinnativegelreagentsdeterminedaccuratelythroughinductivelycoupledplasmameasurements |