Cargando…
Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients
The epoc(®) blood analysis system (Epocal Inc., Ottawa, Ontario, Canada) is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapid...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749944/ https://www.ncbi.nlm.nih.gov/pubmed/26937460 http://dx.doi.org/10.1016/j.dib.2016.01.040 |
_version_ | 1782415345401724928 |
---|---|
author | Chen, Jianing Gorman, Monique O’Reilly, Bill Chen, Yu |
author_facet | Chen, Jianing Gorman, Monique O’Reilly, Bill Chen, Yu |
author_sort | Chen, Jianing |
collection | PubMed |
description | The epoc(®) blood analysis system (Epocal Inc., Ottawa, Ontario, Canada) is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc(®) system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc(®) meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters. |
format | Online Article Text |
id | pubmed-4749944 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-47499442016-03-02 Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients Chen, Jianing Gorman, Monique O’Reilly, Bill Chen, Yu Data Brief Data Article The epoc(®) blood analysis system (Epocal Inc., Ottawa, Ontario, Canada) is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc(®) system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc(®) meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters. Elsevier 2016-01-30 /pmc/articles/PMC4749944/ /pubmed/26937460 http://dx.doi.org/10.1016/j.dib.2016.01.040 Text en © 2016 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Data Article Chen, Jianing Gorman, Monique O’Reilly, Bill Chen, Yu Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients |
title | Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients |
title_full | Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients |
title_fullStr | Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients |
title_full_unstemmed | Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients |
title_short | Linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients |
title_sort | linearity analysis and comparison study on the epoc(®) point-of-care blood analysis system in cardiopulmonary bypass patients |
topic | Data Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4749944/ https://www.ncbi.nlm.nih.gov/pubmed/26937460 http://dx.doi.org/10.1016/j.dib.2016.01.040 |
work_keys_str_mv | AT chenjianing linearityanalysisandcomparisonstudyontheepocpointofcarebloodanalysissystemincardiopulmonarybypasspatients AT gormanmonique linearityanalysisandcomparisonstudyontheepocpointofcarebloodanalysissystemincardiopulmonarybypasspatients AT oreillybill linearityanalysisandcomparisonstudyontheepocpointofcarebloodanalysissystemincardiopulmonarybypasspatients AT chenyu linearityanalysisandcomparisonstudyontheepocpointofcarebloodanalysissystemincardiopulmonarybypasspatients |