Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure
BACKGROUND: Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary arte...
Autores principales: | Shojaeifard, Maryam, Ghaedian, Tahereh, Yaghoobi, Nahid, Malek, Hadi, Firoozabadi, Hasan, Bitarafan-Rajabi, Ahmad, Haghjoo, Majid, Amin, Ahmad, Azizian, Nasrin, Rastgou, Feridoon |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750009/ https://www.ncbi.nlm.nih.gov/pubmed/26889455 http://dx.doi.org/10.5812/cardiovascmed.29005 |
Ejemplares similares
-
The Effect of Milk, Water and Lemon Juice on Various Subdiaphragmatic Activity-Related Artifacts in Myocardial Perfusion Imaging
por: Malek, Hadi, et al.
Publicado: (2015) -
LV Dyssynchrony Assessed With Phase Analysis on Gated Myocardial Perfusion SPECT Can Predict Response to CRT in Patients With End-Stage Heart Failure
por: Azizian, Nasrin, et al.
Publicado: (2014) -
The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
por: Sarebani, Maghsoud, et al.
Publicado: (2020) -
Respiratory Motion Detection and Correction in ECG-Gated SPECT: a New Approach
por: Bitarafan, Ahmad, et al.
Publicado: (2008) -
Myocardial Perfusion SPECT Imaging Radiomic Features and Machine Learning Algorithms for Cardiac Contractile Pattern Recognition
por: Sabouri, Maziar, et al.
Publicado: (2022)