Cargando…
Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®))
INTRODUCTION: Pulmonary vein reconnection after pulmonary vein isolation (PVI) is a significant problem in the treatment of paroxysmal atrial fibrillation (AF). We report about patients who underwent contact force (CF) guided PVI using CF catheter and compared them to patients with PVI using an abla...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750134/ https://www.ncbi.nlm.nih.gov/pubmed/26937108 http://dx.doi.org/10.1016/j.ipej.2015.07.004 |
_version_ | 1782415384118296576 |
---|---|
author | Fichtner, Stephanie Reents, Tilko Ammar, Sonia Semmler, Verena Kathan, Susanne Dillier, Roger Buiatti, Alexandra Hessling, Gabriele Deisenhofer, Isabel |
author_facet | Fichtner, Stephanie Reents, Tilko Ammar, Sonia Semmler, Verena Kathan, Susanne Dillier, Roger Buiatti, Alexandra Hessling, Gabriele Deisenhofer, Isabel |
author_sort | Fichtner, Stephanie |
collection | PubMed |
description | INTRODUCTION: Pulmonary vein reconnection after pulmonary vein isolation (PVI) is a significant problem in the treatment of paroxysmal atrial fibrillation (AF). We report about patients who underwent contact force (CF) guided PVI using CF catheter and compared them to patients with PVI using an ablation catheter with enhanced tip irrigation. METHODS: A total of 59 patients were included in the analysis. In 30 patients circumferential PVI was performed using the Thermocool Smarttouch(®) ablation catheter (ST) whereas in 29 patients circumferential PVI using the Thermocool Surround Flow SF(®) ablation catheter (SF) was performed. Patients were compared in regard to procedure time, fluoroscopy time/dose as well as RF-application duration and completeness of PVI. Adverse events (pericardial effusion, PV stenosis, stroke, death) were evaluated. The presence of sinus rhythm off antiarrhythmic medication was assessed during 6 months follow-up using multiple 7 day Holter-ECGs. RESULTS: In both groups, all PVs were isolated without serious adverse events. Procedure time was 2.15 ± 0.5 h (ST) vs. 2.37 ± 1.13 h (SF) (p = 0.19). Duration of RF-applications was 46.6 ± 18 min (ST) and 49.8 ± 19 min (SF) (p = 0.52). Fluoroscopy time was 25.2 ± 13 min (ST) vs. 29 ± 18 min (SF), fluoroscopy dose 2675.6 ± 1658 versus 3038.3 ± 1997 cGym(2) (p = 0.36 and 0.46 respectively). Sinus rhythm off antiarrhythmic medication validated with 7 day Holter ECGs was present in both groups in 72% of patients after 6 months of follow up. CONCLUSION: PVI using the new contact force catheter is safe and effective in patients with paroxysmal AF. |
format | Online Article Text |
id | pubmed-4750134 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-47501342016-03-02 Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®)) Fichtner, Stephanie Reents, Tilko Ammar, Sonia Semmler, Verena Kathan, Susanne Dillier, Roger Buiatti, Alexandra Hessling, Gabriele Deisenhofer, Isabel Indian Pacing Electrophysiol J Original Article INTRODUCTION: Pulmonary vein reconnection after pulmonary vein isolation (PVI) is a significant problem in the treatment of paroxysmal atrial fibrillation (AF). We report about patients who underwent contact force (CF) guided PVI using CF catheter and compared them to patients with PVI using an ablation catheter with enhanced tip irrigation. METHODS: A total of 59 patients were included in the analysis. In 30 patients circumferential PVI was performed using the Thermocool Smarttouch(®) ablation catheter (ST) whereas in 29 patients circumferential PVI using the Thermocool Surround Flow SF(®) ablation catheter (SF) was performed. Patients were compared in regard to procedure time, fluoroscopy time/dose as well as RF-application duration and completeness of PVI. Adverse events (pericardial effusion, PV stenosis, stroke, death) were evaluated. The presence of sinus rhythm off antiarrhythmic medication was assessed during 6 months follow-up using multiple 7 day Holter-ECGs. RESULTS: In both groups, all PVs were isolated without serious adverse events. Procedure time was 2.15 ± 0.5 h (ST) vs. 2.37 ± 1.13 h (SF) (p = 0.19). Duration of RF-applications was 46.6 ± 18 min (ST) and 49.8 ± 19 min (SF) (p = 0.52). Fluoroscopy time was 25.2 ± 13 min (ST) vs. 29 ± 18 min (SF), fluoroscopy dose 2675.6 ± 1658 versus 3038.3 ± 1997 cGym(2) (p = 0.36 and 0.46 respectively). Sinus rhythm off antiarrhythmic medication validated with 7 day Holter ECGs was present in both groups in 72% of patients after 6 months of follow up. CONCLUSION: PVI using the new contact force catheter is safe and effective in patients with paroxysmal AF. Elsevier 2015-07-29 /pmc/articles/PMC4750134/ /pubmed/26937108 http://dx.doi.org/10.1016/j.ipej.2015.07.004 Text en Copyright © 2015, Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Fichtner, Stephanie Reents, Tilko Ammar, Sonia Semmler, Verena Kathan, Susanne Dillier, Roger Buiatti, Alexandra Hessling, Gabriele Deisenhofer, Isabel Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®)) |
title | Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®)) |
title_full | Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®)) |
title_fullStr | Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®)) |
title_full_unstemmed | Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®)) |
title_short | Pulmonary vein isolation using new technologies to improve ablation lesion formation: Initial results comparing enhanced catheter tip irrigation (Surround Flow(®)) with contact force measurement (Smarttouch(®)) |
title_sort | pulmonary vein isolation using new technologies to improve ablation lesion formation: initial results comparing enhanced catheter tip irrigation (surround flow(®)) with contact force measurement (smarttouch(®)) |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750134/ https://www.ncbi.nlm.nih.gov/pubmed/26937108 http://dx.doi.org/10.1016/j.ipej.2015.07.004 |
work_keys_str_mv | AT fichtnerstephanie pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT reentstilko pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT ammarsonia pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT semmlerverena pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT kathansusanne pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT dillierroger pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT buiattialexandra pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT hesslinggabriele pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch AT deisenhoferisabel pulmonaryveinisolationusingnewtechnologiestoimproveablationlesionformationinitialresultscomparingenhancedcathetertipirrigationsurroundflowwithcontactforcemeasurementsmarttouch |