Lower periprosthetic bone loss and good fixation of an ultra-short stem compared to a conventional stem in uncemented total hip arthroplasty: A randomized clinical trial with DXA and RSA in 51 patients
Background and purpose — We hypothesized that an ultra-short stem would load the proximal femur in a more physiological way and could therefore reduce the adaptive periprosthetic bone loss known as stress shielding. Patients and methods — 51 patients with primary hip osteoarthritis were randomized t...
Autores principales: | Salemyr, Mats, Muren, Olle, Ahl, Torbjörn, Bodén, Henrik, Eisler, Thomas, Stark, André, Sköldenberg, Olof |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750763/ https://www.ncbi.nlm.nih.gov/pubmed/26134386 http://dx.doi.org/10.3109/17453674.2015.1067087 |
Ejemplares similares
-
Good stability but high periprosthetic bone mineral loss and late-occurring periprosthetic fractures with use of uncemented tapered femoral stems in patients with a femoral neck fracture: A 5-year follow-up of 31 patients using RSA and DXA
por: Sköldenberg, Olof G, et al.
Publicado: (2014) -
Cemented compared to uncemented femoral stems in total hip replacement for displaced femoral neck fractures in the elderly: study protocol for a single-blinded, randomized controlled trial (CHANCE-trial)
por: Chammout, Ghazi, et al.
Publicado: (2016) -
Denosumab for treating periprosthetic osteolysis; study protocol for a randomized, double-blind, placebo-controlled trial
por: Sköldenberg, Olof, et al.
Publicado: (2016) -
No effect of risedronate on femoral periprosthetic bone loss following total hip arthroplasty: A 4-year follow-up of 61 patients in a double-blind, randomized placebo-controlled trial
por: Muren, Olle, et al.
Publicado: (2015) -
The Ringloc liner compared with the Hexloc liner in total hip arthroplasty
por: Olof, Sköldenberg, et al.
Publicado: (2009)