Cargando…
Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with tran...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750776/ https://www.ncbi.nlm.nih.gov/pubmed/26145721 http://dx.doi.org/10.3109/17453674.2015.1068635 |
_version_ | 1782415480611405824 |
---|---|
author | Khemka, Aditya Frossard, Laurent Lord, Sarah J Bosley, Belinda Al Muderis, Munjed |
author_facet | Khemka, Aditya Frossard, Laurent Lord, Sarah J Bosley, Belinda Al Muderis, Munjed |
author_sort | Khemka, Aditya |
collection | PubMed |
description | Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with transtibial amputation and knee arthritis. We report on the feasibility of combining total knee replacement (TKR) with an osseointegrated implant for prosthetic attachment. Patients and methods — We retrospectively reviewed all 4 cases (aged 38–77 years) of transtibial amputations managed with osseointegration and TKR in 2012–2014. The below-the-knee prosthesis was connected to the tibial base plate of a TKR, enabling the tibial residuum and knee joint to act as weight-sharing structures. A 2-stage procedure involved connecting a standard hinged TKR to custom-made implants and creation of a skin-implant interface. Clinical outcomes were assessed at baseline and after 1–3 years of follow-up using standard measures of health-related quality of life, ambulation, and activity level including the questionnaire for transfemoral amputees (Q-TFA) and the 6-minute walk test. Results — There were no major complications, and there was 1 case of superficial infection. All patients showed improved clinical outcomes, with a Q-TFA improvement range of 29–52 and a 6-minute walk test improvement range of 37–84 meters. Interpretation — It is possible to combine TKR with osseointegrated implants. |
format | Online Article Text |
id | pubmed-4750776 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-47507762016-03-02 Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases Khemka, Aditya Frossard, Laurent Lord, Sarah J Bosley, Belinda Al Muderis, Munjed Acta Orthop Articles Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with transtibial amputation and knee arthritis. We report on the feasibility of combining total knee replacement (TKR) with an osseointegrated implant for prosthetic attachment. Patients and methods — We retrospectively reviewed all 4 cases (aged 38–77 years) of transtibial amputations managed with osseointegration and TKR in 2012–2014. The below-the-knee prosthesis was connected to the tibial base plate of a TKR, enabling the tibial residuum and knee joint to act as weight-sharing structures. A 2-stage procedure involved connecting a standard hinged TKR to custom-made implants and creation of a skin-implant interface. Clinical outcomes were assessed at baseline and after 1–3 years of follow-up using standard measures of health-related quality of life, ambulation, and activity level including the questionnaire for transfemoral amputees (Q-TFA) and the 6-minute walk test. Results — There were no major complications, and there was 1 case of superficial infection. All patients showed improved clinical outcomes, with a Q-TFA improvement range of 29–52 and a 6-minute walk test improvement range of 37–84 meters. Interpretation — It is possible to combine TKR with osseointegrated implants. Informa Healthcare 2015-11 /pmc/articles/PMC4750776/ /pubmed/26145721 http://dx.doi.org/10.3109/17453674.2015.1068635 Text en Copyright: © Nordic Orthopaedic Federation 2015 http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the CC-BY-NC-ND 3.0 License which permits users to download and share the article for non-commercial purposes, so long as the article is reproduced in the whole without changes, and provided the original source is credited. |
spellingShingle | Articles Khemka, Aditya Frossard, Laurent Lord, Sarah J Bosley, Belinda Al Muderis, Munjed Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases |
title | Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases |
title_full | Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases |
title_fullStr | Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases |
title_full_unstemmed | Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases |
title_short | Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases |
title_sort | osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750776/ https://www.ncbi.nlm.nih.gov/pubmed/26145721 http://dx.doi.org/10.3109/17453674.2015.1068635 |
work_keys_str_mv | AT khemkaaditya osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases AT frossardlaurent osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases AT lordsarahj osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases AT bosleybelinda osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases AT almuderismunjed osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases |