Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases

Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with tran...

Descripción completa

Detalles Bibliográficos
Autores principales: Khemka, Aditya, Frossard, Laurent, Lord, Sarah J, Bosley, Belinda, Al Muderis, Munjed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750776/
https://www.ncbi.nlm.nih.gov/pubmed/26145721
http://dx.doi.org/10.3109/17453674.2015.1068635
_version_ 1782415480611405824
author Khemka, Aditya
Frossard, Laurent
Lord, Sarah J
Bosley, Belinda
Al Muderis, Munjed
author_facet Khemka, Aditya
Frossard, Laurent
Lord, Sarah J
Bosley, Belinda
Al Muderis, Munjed
author_sort Khemka, Aditya
collection PubMed
description Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with transtibial amputation and knee arthritis. We report on the feasibility of combining total knee replacement (TKR) with an osseointegrated implant for prosthetic attachment. Patients and methods — We retrospectively reviewed all 4 cases (aged 38–77 years) of transtibial amputations managed with osseointegration and TKR in 2012–2014. The below-the-knee prosthesis was connected to the tibial base plate of a TKR, enabling the tibial residuum and knee joint to act as weight-sharing structures. A 2-stage procedure involved connecting a standard hinged TKR to custom-made implants and creation of a skin-implant interface. Clinical outcomes were assessed at baseline and after 1–3 years of follow-up using standard measures of health-related quality of life, ambulation, and activity level including the questionnaire for transfemoral amputees (Q-TFA) and the 6-minute walk test. Results — There were no major complications, and there was 1 case of superficial infection. All patients showed improved clinical outcomes, with a Q-TFA improvement range of 29–52 and a 6-minute walk test improvement range of 37–84 meters. Interpretation — It is possible to combine TKR with osseointegrated implants.
format Online
Article
Text
id pubmed-4750776
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-47507762016-03-02 Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases Khemka, Aditya Frossard, Laurent Lord, Sarah J Bosley, Belinda Al Muderis, Munjed Acta Orthop Articles Background and purpose — Osseointegrated implants are an alternative for prosthetic attachment in individuals with amputation who are unable to wear a socket. However, the load transmitted through the osseointegrated fixation to the residual tibia and knee joint can be unbearable for those with transtibial amputation and knee arthritis. We report on the feasibility of combining total knee replacement (TKR) with an osseointegrated implant for prosthetic attachment. Patients and methods — We retrospectively reviewed all 4 cases (aged 38–77 years) of transtibial amputations managed with osseointegration and TKR in 2012–2014. The below-the-knee prosthesis was connected to the tibial base plate of a TKR, enabling the tibial residuum and knee joint to act as weight-sharing structures. A 2-stage procedure involved connecting a standard hinged TKR to custom-made implants and creation of a skin-implant interface. Clinical outcomes were assessed at baseline and after 1–3 years of follow-up using standard measures of health-related quality of life, ambulation, and activity level including the questionnaire for transfemoral amputees (Q-TFA) and the 6-minute walk test. Results — There were no major complications, and there was 1 case of superficial infection. All patients showed improved clinical outcomes, with a Q-TFA improvement range of 29–52 and a 6-minute walk test improvement range of 37–84 meters. Interpretation — It is possible to combine TKR with osseointegrated implants. Informa Healthcare 2015-11 /pmc/articles/PMC4750776/ /pubmed/26145721 http://dx.doi.org/10.3109/17453674.2015.1068635 Text en Copyright: © Nordic Orthopaedic Federation 2015 http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the CC-BY-NC-ND 3.0 License which permits users to download and share the article for non-commercial purposes, so long as the article is reproduced in the whole without changes, and provided the original source is credited.
spellingShingle Articles
Khemka, Aditya
Frossard, Laurent
Lord, Sarah J
Bosley, Belinda
Al Muderis, Munjed
Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
title Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
title_full Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
title_fullStr Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
title_full_unstemmed Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
title_short Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
title_sort osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4750776/
https://www.ncbi.nlm.nih.gov/pubmed/26145721
http://dx.doi.org/10.3109/17453674.2015.1068635
work_keys_str_mv AT khemkaaditya osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases
AT frossardlaurent osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases
AT lordsarahj osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases
AT bosleybelinda osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases
AT almuderismunjed osseointegratedtotalkneereplacementconnectedtoalowerlimbprosthesis4cases