The occlusion tests and end-expiratory esophageal pressure: measurements and comparison in controlled and assisted ventilation
BACKGROUND: Esophageal pressure is used as a reliable surrogate of the pleural pressure. It is conventionally measured by an esophageal balloon placed in the lower part of the esophagus. To validate the correct position of the balloon, a positive pressure occlusion test by compressing the thorax dur...
Autores principales: | Chiumello, Davide, Consonni, Dario, Coppola, Silvia, Froio, Sara, Crimella, Francesco, Colombo, Andrea |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Paris
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4751101/ https://www.ncbi.nlm.nih.gov/pubmed/26868503 http://dx.doi.org/10.1186/s13613-016-0112-1 |
Ejemplares similares
-
Dynamic hyperinflation and intrinsic positive end-expiratory pressure in ARDS patients
por: Coppola, Silvia, et al.
Publicado: (2019) -
Time required for gas exchange equilibration after a change of positive end-expiratory pressure in acute respiratory distress syndrome
por: Coppola, S, et al.
Publicado: (2013) -
Protective lung ventilation during general anesthesia: is there any evidence?
por: Coppola, Silvia, et al.
Publicado: (2014) -
Positive end-expiratory pressure in COVID-19 acute respiratory distress syndrome: the heterogeneous effects
por: Chiumello, Davide, et al.
Publicado: (2021) -
Effects of change in the expiratory trigger during pressure support ventilation in COPD
por: Chiumello, D, et al.
Publicado: (2006)